Laserfiche WebLink
<br />15'-6" <br /> <br /> 6"MIN.\TYP.) <br /> 1'-6" 2'_611 1'_0" 1'-11" 1'-11" 21_6" 3'-8" <br />'" <br /> A ^ < 4 0 <br /> A ^ ^ <br /> < . . < . . . ~ <br /> , <br />i'- N PRIMARY FUTURE ~ <br />, A BBU BTS BTS <br />, N < <br />N 4 <br /> < . . . . 6 A <br /> . . " < B <br /> e . 4 A < 4 <br /> '" A A " <br /> 4 4 <br /> 4 '" 4 4 4 <br />N '" " < <br />, 44 6 <br />;,. 4 A 4 4 '" <br /> 4 4 4 <br /> 4 4 <br /> 4 4 4 <br /> .~ < < <br /> ~ <br /> 4 <br /> <br />12" <br /> <br />13'-6" <br /> <br />A <br /> <br />r- ,-,- ,--r-,--T--r-,--T--r-,--,--r-,--, <br />I I I I I I i I I I I I I 1 1 <br />I n---r--r--l--j--T--r-j--T--r-j--i--r-jl I <br />r-T,-,--T--,-,--T--,-,--T--r-,--T--r-,l-' <br />j II I I I I I I I I I j II <br />~_+~_~__L__L_~__+__h_~__+__L_~__~__L_~~_J <br />J 11 I I I I ; I I ! I I j j 11 1 <br />I il I 1 I I I I I I j I Ii <br />~-~~-~--~--~-~--~--~-~--+--~-~--~--~-~~-~ <br />I \1 I I I I I I I I I I 11 I <br />I II I I J I , I I 1 I I I I II I <br />r-Tr-j--T--r-l--T--r-l--T--r-i--l--r-II-l <br />11 I I I I I I j I I I ! I II ' <br />L_+L_J__L__L_~__~ _L_~_ ~__L_~__~__L_~2_~ <br />I 11 I I I I I I i I I I I I I! j <br />J jl I I J I I 1 I 1 1 1 I I II 1 <br />t--H:::-::f.--t--f--:;i--:l:..-- -::i~ ~:J.:--c-':::i-.-'i.-.-c.--::::I..4- <br />I 1--- 1--1 ---j-- 1-.-1---1 -- 1 - J --I - I--I--j - t j <br />L__L_~_ L__L_~__~__L ~ __~__L_~__~__L_~__~ <br /> <br />A <br /> <br />#5@12"O.C <br />(EACH WAY) <br /> <br />1 <br /> <br />EQUIPMENT ENCLOSURE FOUNDATION AND FLOOR SLAB PLAN <br /> <br />SCALE: 1f2" = 1'-0' (112' = 2'-O'IF 11 X 17 SHEET SIZE 1 <br /> <br />,~U08 <br />(+3"AGl) <br /> <br /> <br />COMPACTED COHESIVE OR <br />CA.6 GRANULAR BACKFILL OR <br />APPROVED EOUAL <br />#SRE8AR@12*O.C.EACHWAY <br /> <br />TlGMDE <br />(+O..O"AGL) <br /> <br /> <br />8IFOUNDATION <br />(.1S-AGL) <br /> <br />SECTION B-B <br /> <br />STRUCTURAL NOTES: <br /> <br />A EQUIPMENT CABINET FOUNDAT!ON <br />1_ REFER TO CIVil DRAWINGS FOR ORIENTATiON OF THE FOUNDATIONS <br />2_ EQUIPEMENT CABINET FOUNDATION IS DESiGNED FOR THE FOLLOWING lOADS. <br />ENCLOSURE OEAD LOAD; 12.000 LBS <br />UVElOAO,SOPSf <br />3. FOOTiNGS SHALL BEAR ON VIRGIN SOIL PRESURE OF 2,000 PSI' <br />4. SLAB TOBE LEVEl::t1!4". <br />5 A MINIMUM Of 18" EMBEDMENT <br />6 FINAL SITE DESIGN IS THE RESPONSIBiUTY OF THE SITE CONTRACTOR <br />7 SlAB FOUNDATION DESIGNED ASSUMING MAXIMUM SOil PlASTlCITY INDEX Of 27 <br />8 SUBGRADE PREPARATION: <br />A REMOVE ALL SOilS CONTAINING TOPSOIL ORGANIC MATERiAlS, ANDJOR fill MATERIALS FROMWlTHIN <br />AREA OF ENCLOSURE FOUNDATION. <br />B. PROOF ROLL RESULTING SUBGRADE WlTH A HEAVILY lOADED SINGLE AXLE ROllER OR SIMIlAR VEHICLE <br />(20 TON lOADl. CONTRACTOR SHAll UNDERCUT AND REPlACE WITH ENGINEEREO Fill (COMPACTED <br />lOOT CA-S MATERIAL) OR APPROVED EQUAL All lOOSE SOFT OR UNSTABLE AREAS REVEALED DURING <br />PROQfROLUNGASDIRECTED, <'> <br />C. BACKFill AND COMf'ACTTHE AREA WtTHIN THE BUILDING FOUNDATION BETWEEN RESULTANT <br />SUBGRADE AND FOUNDATION WAtl WITH CA-6 GRANULAR MATERIAL OR APPROVED EQUAL <br />9. FOUNDATION WAll SHAll BE BACKFIllED EVENLY ON EACH SIDE Of' THE WAll OR WAltS SHAll BE <br />ADEQUATElY BRACED BY THE CONTRIICTOR UNTIL FLOOR SLAB HAS PLACED AND CURED fOR 72 <br />HOURS MINiMUM. <br />10.1 NEW FOUNDAT!ON OESIGN HEREIN IS BASED ON SOilS HAVING A MiNIMUM CAPACITY Of <br />2.000 POUNDS PER SQUARE FOOT (PSF). <br />lO.2 GC SHALL HAVE A GEOTECHNICAL ENGINEER PRESENT AT THE TIME OFCAISSON <br />INST AUA liON TO VERIFY SOILS <br />10.3 GC SHAll PRESENT AN ENGINEERiNG REPORT DOCUMENTING THAT CAISSON W/lS <br />INSTALLED PER THE ENGiNEER!NG SPECIFICATIONS <br />lOA NO GEOTECHNICAL ENGINEERING REPORT HAS BEEN SUPPUED TO CONCORDIA THESE <br />PLANS ARE BASEO ON SOILS AT THE BASE HAVING A CAPACITY OF 2000PSF.GC SHAll <br />NOTIFY ENGINEER OF DISCREPANCIES IMMEOlA TEL Y. <br /> <br />BBU CABINET <br /> <br />9" <br /> <br />~ ~ <br />Dd <br />~ <br /> <br />GC TO lEVEL <br />CABINETS WI <br />WASHERS <br /> <br /> <br />3-#5@EACHFACE <br />TYP, <br /> <br />DETAIL "A" <br />SCALE: N.T.S. <br /> <br />12" <br /> <br />NOTE: <br /> <br />1. USE GALVANIZED Hll TI EXPANSION ANCHORS OR, APPROVED <br />EQUAL, FOR EQUIPMENT ANCHORAGE. <br /> <br />2, FOR S!ZE AND lOCAT!ON OF ANCHORS AND OTHER <br />REQUIREMENT, SEE EQUIPMENT VENDOR DRAWINGS <br /> <br />__',- ,!SEEOETAIL"A" <br /> <br /> <br />, \ /_f~EEom"'8' <br />\ // " <br />, <br /> <br /> <br />'" <br />~ <br /> <br />B <br /> <br />ur ~ <br />in F-- <br /> <br />'" <br /> <br />1)BBU.(2)S5000 <br />& (1) NOKlAflEXl <br />TOTAl OF (4) <br />CABINETS <br /> <br />000 <br /> <br />.----- <br /> <br />/ <br />/ <br /> <br />~ <br />192.\;oID <br /> <br />6" MtN COMPACT <br />GRAVEl BASE <br /> <br />EXISTING <br />SUBGRADE <br /> <br />SECTION A-A <br /> <br />NEW flEXl POST <br />2 112" 0 STD. PlPE <br /> <br />Co <br /> <br /> <br />#4TtE@12-0.C <br /> <br />t2-x1Z'x3lS"Thck8Mfir>gPlatfrwl <br />(4}NEW9l16"OlA.HOlES <br /> <br />(4)NEW1l2-0xS""lONG <br />Hll Tl ANCHOR BOLTS <br /> <br />44t4@12"'@EACHCORNERTYP <br />314" CHAMFER TYP. <br />2'-6- <br /> <br />~". <br /> <br />. <br /> <br />)~d <br />~~~~ <br />~. 'l;"'?i <br />~" ~<(<S <br />/::</'0 . <br />'>>. /:::y;v.>:i <br />/. /::{//,:/i <br />''.y ::'./'0:;,:$ <br />/'<:1Z;LZ1iR:1 <br />>/~;1' . Nl.../;:'- <br />,.'. ~V::'.,'0! <br />Lb:u.'-..:.._/>:s.-'i,)(/:::J <br /> <br />DETAIL "B" <br />SCALE: N.T.S. <br /> <br />6" MtN COMPACT <br />GRAVEL BASE <br /> <br />q;. . -Mobile- <br /> <br />T-MOBllE <br />8550 WEST BRYN MAWR AVE. <br />SUITE 100 <br />CHICAGO, IL60631 <br />MAIN: (773) 444---5400 <br /> <br />CONCORDIA, l TO <br />A PROFESSIONAL DESIGN FIRM <br />~ UCENSEI/184004952-DBA <br />----:..~~CORDIA WIRELESS, me <br />~ - 505 E GOLF ROAD <br />SUITED&E <br />ARUNGTON HEIGHTS,IL600Q5 <br />MAIN; (847) 981--0801 <br /> <br />(C)Collcor<!;a 2001.2009, Copyngt>\Nolice: <br />These Docull\0llSlOrnw1ngs Are Pfoduced by and <br />Are The,e-fom The IntellGcluaJ PropeltyofConcoroia <br />Gro"p Of Companies. Do Not Copy, Reproduca. <br />Reverse-Engineer Of Rllpilcale Any Parts of These <br />Oocumenls In any Manner Without ObIaining Wril!en <br />eo"3ent F,om The C<nloordia Group. <br /> <br />PROJECT NO: T-ijMx1S'-6" CONCRETE PAD <br /> <br />DRAWN BY: KF <br /> <br />CHECKED BY: OMS <br /> <br />CHECKED BY: RH <br /> <br />APPROVED BY: GMS. TP <br /> <br />NEW T -MOBILE <br />7'.6" X 15'-6" <br />CONCRETE PAD <br /> <br />EQUIPMENT PAD <br />DETAILS & NOTES <br /> <br />5-1 <br />