Laserfiche WebLink
d,soo <br /> 'or.Public Health <br /> MADISON&DANE COUNTY Page of <br /> Healthy people and plates POWTS OWNER'S MANUAL & MANAGEMENT PLAN <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> Owner: ( A'MVS I A OJ <br /> Tank Manufacturer: (1/��A�� ❑NA <br /> Permit:U�tl\\b5C) QUf�t2t?`{ gj Septic ❑Dose ❑Holding Volume 1,: e;to <br /> gal <br /> I POWTS# Tank Manufacturer: M EA DE ❑NA <br /> 11 ❑Septic fJ Dose ❑Holding Volume (Q 5 0 gal <br /> DESIGN PARAMETERS Vertical Distance Tank Bottoms)to Service Pad: 4 I.5 ft <br /> Number of Bedrooms: 9 ❑NA Horizontal Distance Tank(s)to Service Pad: -15 0 ft <br /> Number of Public Facility Units: ❑NA Specific servicing mechanics must be provide if vertical is>15 feet or if <br /> Estimated(average)Flow: 'ga gamey horizontal is>150 feet.Specific instructions on plan addendum. <br /> Design(peak)Flow=estimated x 1.5: Q ga l/day <br /> In Situ Soil Application Rate: ` - _ gal/day/ft' Effluent Filter Manufacturer 0 ya Eat(0 ❑NA <br /> Standard Domestic Influent/Effluent Monthly average Effluent Filter Model: KT S <br /> Fats,Oil&Grease(FOG) 530 mg/L Pump Manufacturer: GrC)uW S 0 NA <br /> Biochemical Oxygen Demand(BOD5) 5220 mg/L ❑NA Pump Model: E PQ 4 i I F <br /> Total Suspended Solids(TSS) 5150 mg/L Pretreatment Unit <br /> High Strength Influent/Effluent Monthly average Manufacturer: <br /> Fats,Oil&Grease(FOG) >30 mg/L ❑Mechanical Aeration ❑Peat Filter <br /> Biochemical Oxygen Demand(BODe) >220 mg/L ®NA - ❑Disinfection 0 Wetland RI NA <br /> Total Suspended Solids(TSS) >150 mg/L ❑Sand/Gravel Filter 0 Other: <br /> Pretreated Effluent Monthly average Soil Absorption System <br /> Biochemical Oxygen Demand(BODS) 530 mg/L ❑In-Ground(gravity) ❑In-Ground(pressure) ®NA <br /> Total Suspended Solids(TSS) 530 mg/L ®NA ❑At-Grade ❑Mound <br /> Fecal Coliform(geometric mean) 5104 cfu/100m1 ❑Drip-Line 0 Other. <br /> Maximum Effluent Particle Size: 1/8 in dia. 0 NA <br /> Other. 2 NA Other ❑NA <br /> MAINTENANCE SCHEDULE <br /> Service Event 1 Service Frequency <br /> Pump out content of tank(s) E When combined sludge and scum equals one-third(1/3)of tank volume. <br /> When the high water alarm is activated. <br /> Inspect condition of tank(s) At least once very 3 years. ❑ NA <br /> Inspect dispersal cells(s) At least once very 3 years. 0 NA <br /> Clean effluent filter Y EA R,Ly ❑NA <br /> Inspect pump,pump controls&alarm 4,1 i-l-tz;iJ Pu fu p ED /�7 LA.R M ED - 0 NA <br /> Flush laterals and pressure test '-� 7 !� ❑ NA <br /> Other: ❑NA <br /> Other ❑NA <br /> MAINTENANCE INSTRUCTIONS <br /> Inspections of tanks and dispersal cells shall be made by an Individual carrying one of the following licenses or certifications:Master Plumber,Master <br /> Plumber Restricted Sewer, POWTS Inspector, POWTS Maintainer, Septage Servicing Operator(pumper). Tank inspections must include a visual <br /> Inspection of the tank(s)to identify any missing or broken hardware,identify any cracks or leaks,measure the volume of combined sludge and scum and <br /> a check for any back up or ponding of effluent on the ground surface.If the volume of sludge and scum is less than one—third(1/3)of the liquid volume <br /> of the tank,the tank does not need to be pumped and identifying cracks in floor or walls of the tank may not be possible at that time.The dispersal cell(s) <br /> shall be visually inspected to check the effluent levels in the observation pipes and to check for any ponding of effluent on the ground surface.The <br /> ponding of effluent on the ground surface may indicate a falling condition and requires the Immediate notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum in any treatment tank equals one-third(1/3)or more of the tank volume,the entire contents of the <br /> tank shall be removed by a Septage Servicing Operator and disposed of in accordance with chapter NR 113,Wisconsin Administrative Code. <br /> 31W2010•POW TSMOTpbn.d oc <br />