Laserfiche WebLink
•Public Health <br /> MADISON&DANE COUNTY Page_of <br /> HealtigPeoPle mrdpfaca POWTS OWNER'S MANUAL&MANAGEMENT PLAN <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> Owner: Tank Manufacturer. M (jE ❑NA <br /> 1/0401 A-I) ` in/►fs ❑Septic ❑Dose ❑Holding Volume I te LSO gal <br /> Permit I POWTS# Tank Manufacturer: ktgA QE Q NA <br /> 1 ❑Septic ❑Dose ❑Holding Volume 800 gal <br /> DESIGN PARAMETERS Vertical Distance Tank Bottom(s)to Service Pad: 4 15 ft <br /> Number of Bedrooms: 5 ❑NA Horizontal Distance Tank(s)to Service Pad: G ISO if <br /> Number of Public Facility Units: ❑NA Specific servicing mechanics must be provide If vertical is>15 feet or if <br /> Estimated(average)Flow: 500 gray horizontal is>150 feet Specific instructions on plan addendum_ <br /> Design(peak)Flow=estimated x 1.5: ISO gavday <br /> In Situ Soil Application Rate: gsWday/fiz Effluent Filter Manufacturer OKEo.CO ❑NA <br /> Standard Domestic Influent/Effluent Monthly average Effluent Filter Model: V i , <br /> Fats,Oil&Grease(FOG) 530 mg/L Pump Manufacturer: crio-LALD g ❑NA <br /> Biochemical Oxygen Demand(BOD5) 120 mg/L ❑NA Pump Model: , Apo S"iY/ <br /> Total Suspended Solids(TSS) 5150 mg/L Pretreatment Unit <br /> High Strength influent/Effluent Monthly average Manufacturer: <br /> Fats,Oil&Grease(FOG) >30 mg/L ❑Mechanical Aeration ❑Peat Filter <br /> Biochemical Oxygen Demand BODS) >220 mg/L RNA ❑Disinfection ❑Wetland ®NA <br /> Total Suspended Solids(TSS) >150 mg/L ❑Sand/Gravel Filter ❑Other: <br /> Pretreated Effluent Monthly average Soil Absorption System <br /> Biochemical Oxygen Demand BODO) 530 mg/L ❑In-Ground(gravity) ❑In-Ground(pressure) ❑NA <br /> Total Suspended Solids(TSS) 530 mg/L ( 'NA ❑At-Grade lS Mound <br /> Fecal Cofiforn(geometric mean) <-10`cfu/100m1 ❑Drip-Line ❑Other: <br /> Maximum Effluent Particle Size: 1/8 in die. ❑NA <br /> Other. RNA Other: ❑NA <br /> • <br /> MAINTENANCE SCHEDULE - <br /> Service Event [ Service Frequency <br /> Pump out contents of tank(s) 10 When combined sludge and scum equals one-third(1/3)of tank volume. , <br /> ❑When the high water alarm is activated. <br /> Inspect condition of tank(s) At least once very 3 years. ❑NA <br /> Inspect dispersal cells(s) At least once very 3 years. _ ❑NA <br /> Clean effluent fitter NI r A If-1--q ❑NA <br /> Inspect pump,pump controls&alarms polity k D ❑NA <br /> Flush laterals and pressure test l ❑NA <br /> Other: ' ❑NA <br /> Other. I ❑NA <br /> MAINTENANCE INSTRUCTIONS <br /> Inspections of tanks and dispersal cells shall be made by an individual carrying one of the following licenses or certifications Master Plumber,Master <br /> Plumber Restricted Sewer,POWTS Inspector,POWTS Maintainer,Septage Servicing Operator(pumper).Tank inspections must include a visual <br /> inspection of the tank(s)to identify any missing or bmken hardware,identify any aacks or leaks,measure the volume of combined sludge and scum and <br /> a check for any back up or pondmg of effluent on the ground surface.If the volume of sludge and scum is less than one-third(1/3)of the liquid volume <br /> of the tank,the tank does not need to be pumped and identifying cracks in floor or walls of the tank may not be poe late at that fine.The dispersal cell(s) <br /> shall be visually inspected to check the effluent levels in the observation pipes and to check for any pending of effluent on the ground surface.The <br /> ponding of effluent on the ground surface may indicate a failing condition and requires the immediate notification of the local regulatory authority_ <br /> When the combined accumulation of sludge and scum in any treatment tank equals one-third(1/3)or more of the tank volume,the entire contents of the <br /> tank shall be removed by a Septage Servicing Operator and disposed of in accordance with chapter NR 113,Wisconsin Administrative Code. <br /> a sorb POwtsMGTISs roc <br />