|
Help
|
About
|
Sign Out
Home
Browse
Search
DCPZP-2015-00072
DaneCounty-Planning
>
Zoning
>
1 Permits
>
2010s
>
2015
>
DCPZP-2015-00072
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/12/2015 4:10:39 PM
Creation date
3/10/2015 4:09:27 PM
Metadata
Fields
Template:
Zoning Permits
AccelaLink
DCPZP-2015-00072
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1:••PUNIC Health , <br /> MADISON&DANE COUNTY Page 2_of i' <br /> Healthy people and places POWTS OWNER'S MANUAL & MANAGEMENT PLAN <br /> FILE INFORMATION - SYSTEM SPECIFICATIONS <br /> •Ow r: // Tank Manufacturer: J7l ea r9 e ❑NA <br /> 11f--it Cam'at e J z/e c;t,./ Peye/s; _ Et Septic. ❑ Dose-. ❑Holding Volume. /02.8G gal <br /> Permit: POWTS# Tank Manufacturer: me a cQ e ❑NA <br /> 0 Septic ®Dose. ❑Holding Volume 9'O D gal <br /> • =DESIGN PARAMETERS Vertical Distance Tank Bottom(s)to Service Pad: /3 ft <br /> • . Number of Bedrooms: `•'/ ❑NA Horizontal Distance Tank(s)to Service Pad: 106 ft <br /> Number.of Public Facility.Units E4 NA Specific servicing mechanics must be provide If vertical Is>15 feet or If <br /> Estimated(average)Flow: , L!O U gal/day horizontal is>150 feet.Specific Instructions on plan addendum. <br /> Design(peak)Flow.=estimated x 1.5: •(, 0 0 gal/day . -. <br /> In Situ Soil Application Rate: /,C . gal/day/ft Effluent Filter Manufacturer 6 c'e w•c-o ❑NA <br /> Standard Domestic Influent/Effluent Monthly average Effluent Filter Model: f 'rte If ej/d i-14.be <br /> Fats;011&Grease(FOG) 530 rng/L. . . . : Pump Manufacturer: . 2-o //e,` ❑NA <br /> Biochemical Oxygen Demand(BODE) 5220 mg/L ❑NA Pump Model: / yo _ . <br /> Total Suspended Solids(TSS) 5150 mg/L Pretreatment Unit <br /> High Strength.Influent/Effluent . Monthly average Manufacturer: . <br /> Fats,011&Grease(FOG) >30 mg/L ❑Mechanical Aeration ❑Peat Filter <br /> Biochemical Oxygen Demand(BOD,) >220 mg/L RI NA • ❑Disinfection ❑Wetland s-NA <br /> Total Suspended Solids(TSS) >150 ing/L - 0 Sand/Gravel Filter ❑Other: <br /> Pretreated Effluent Monthly average Soil Absorption System '- - <br /> Biochemical Oxygen Demand(BOD,) 530 mg/L ❑In-Ground(gravity) ❑In-Ground(pressure) ' ❑NA <br /> Total Suspended Solids(TSS) 530.mg/L G°+NA ❑At-Grade aMound <br /> Fecal Coliform(geometric mean)}!9`-4. <br /> ml ❑Drip-Line 0 Other: <br /> Maximum Effluent Particle Size: • ( 118 In di ❑NA .. . <br /> Other: . _ _ . • . �NA Other: .. <br /> .. RNA <br /> • <br /> MAINTENANCE SCHEDULE '- .• - <br /> Service Event . Service Frequency <br /> Pump out contents of tank(s) El When combined sludge and scum equals one-third(1/3)of tank volume. . . <br /> ❑When the high water alarm is activated. . <br /> Inspect condition of tank(s) : At least once very 3 years. . ❑NA <br /> Inspect dispersal cells(s) ^ At least once very 3 years: -•� - . ❑NA• <br /> Clean-effluent filter ❑NA <br /> Inspect pump,pump controls&alarm Luke,r et/ye' r/ - ❑NA <br /> Flush laterals and pressure test RI NA <br /> Other: IR NA <br /> Other: - la-NA <br /> MAINTENANCE INSTRUCTIONS <br /> inspections of tanks and dispersal cells shall be made by an Individual carrying one of the following licenses or certifications:Master Plumber,Master <br /> Plumber Restricted Sewer, POWTS Inspector, POWTS Maintainer, Septage Servicing Operator(pumper). Tank Inspections must Include a visual <br /> Inspection of the tank(s)to Identify any missing or broken hardware,Identify any cracks or leaks;measure the volume of combined sludge and scum and <br /> a check for any back up or ponding of effluent on the ground surface,if the volume of sludge and scum Is less than one—third(1/3)of the liquid volume <br /> of the tank,the tank does not need to be pumped and Identifying cracks In floor or walls of the tank may not be possible at that time.The dispersal cell(s) <br /> shall be visually Inspected to check the effluent levels In the observation pipes and to check for any ponding of effluent on the ground surface.The <br /> ponding of effluent on the ground surface may Indicate a falling condition and requires the Immediate notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum In any treatment tank equals one-third(1/3)or more of the tank volume,the entire contents of the <br /> tank shall be removed by a Septage Servicing Operator and disposed of In accordance with chapter NR 113,Wisconsin Administrative Code. <br /> 3le/2010•PO W TSMoTplan.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.