Laserfiche WebLink
1.°0, ublic Health Page of S <br /> MADISON&DANE COUNTY <br /> Healthy people and places POWTS OWNER'S MANUAL & MANAGEMENT PLAN <br /> FILE INFORMATION - SYSTEM SPECIFICATIONS <br /> Owner: Tank Manufacturer: , -'t -/-e ❑NA <br /> • e or‘l C iemeh 5 -. ®Septic.0.Dose__ ❑ Holding . Volume. t z ?4 gal <br /> .: Permit: J POWTS# Tank Manufacturer: ❑ NA <br /> ❑ Septic ❑ Dose. 0 Holding Volume gal <br /> • <br /> DESIGN PARAMETERS Vertical Distance Tank Bottoms)to Service Pad: /0 ft <br /> - ,. Number of Bedrooms: 1 0 NA Horizontal Distance Tank(s)to Service Pad: /110 ft <br /> Numbet.of PUblic Facllity.UnIts ❑NA Specific servicing mechanics must be provide If vertical Is>15 feet or If <br /> Estimated(average)Flow: '1 o gal/day horliontal Is>150 feet.Specific Instructions on plan addendum. <br /> Design(peak)Flow.=estimated x 1.5: -6 o 0 . - gal/day , . - - <br /> In Situ Soil Application Rate: r '1 gal/day/ft2 Effluent Filter Manufacturer . t9-.^!r« ❑NA <br /> Standard Domestic Influent/Effluent Monthly average Effluent Filter Model: _rolf 63 'o'oho • <br /> Fats,-Oil&Grease(FOG),530 mg/t.. - • Pump_Manufacturer . . . 'NA. <br /> Biochemical Oxygen Demand(8005) 5220 mg/L ❑ NA Pump Model: . . - . <br /> Total Suspended Solids(TSS) 5150 mg/L Pretreatment Unit <br /> High Strength.Influent/Effluent . Monthly average Manufacturer: <br /> Fats,Oil&Grease(FOG) >30 mg/L ❑Mechanical Aeration - ❑Peat Filter • - <br /> Biochemical Oxygen Demand(8005) >220 mg/L ® NA - ❑Disinfection ❑Wetland L 4JA <br /> Total Suspended Solids(TSS) >150.ing/L - ❑Sand/Gravel Filter ❑Other: <br /> Pretreated Effluent Monthly average Soil Absorption System .. . <br /> Biochemical Oxygen Demand(8005) 530 mg/L In-Ground(gravity) ,-J ❑In-Ground(pressure) ❑NA <br /> Total Suspended Solids(TSS) 530.mg/L Et NA ❑At-Grade ❑Mound <br /> Fecal Coliform(geometric mean) 5104 cfu 100mi ❑Drip-Line ❑Other: <br /> Maximum Effluent Particle Size: • . /8 In dia. ❑ NA .. . . . . <br /> Other: ®NA , .Other: ; .. : - • - ❑NA <br /> MAINTENANCE SCHEDULE .. . • <br /> • . Service Event - - .. • • -. . Service Frequency - . . . <br /> ®When combined sludge.and scum equals one-third(1/3)of tank volume. . <br /> Pump out contents of tanks) ❑When the high water alarm is.activated. .- . . . <br /> Inspect condit(on of tanks) : At least once very 3 years. . ❑NA <br /> Inspect dispersal,celis(s). _ • At least once very 3 years.= • . -• - : -. - - . - ❑NA <br /> Clean-effluent filter 4t 1e,:, nnae et year- <br /> • . - ❑NA <br /> Inspect pump, pump controls&alarm ❑NA <br /> Flush laterals and pressure test • ❑NA <br /> Other: - ❑NA <br /> Other: <br /> - • ❑NA <br /> MAINTENANCE INSTRUCTIONS - <br /> Inspections of tanks and dispersal cells shall be made by an Individual carrying one of the following licenses or certifications:Master Plumber, Master <br /> Plumber Restricted Sewer, POWTS Inspector, POWTS Maintainer, Septage Servicing Operator (pumper). Tank Inspections must include a visual <br /> Inspection of the tanks)to Identify any missing or broken hardware,Identify any cracks or leaks;measure the volume Of combined sludge and scum and <br /> a check for any back up or pending of effiuent on the ground surface.If the volume of sludge and scum is less than one—third(1/3)of the liquid volume <br /> of the tank,the tank does not need to be pumped and Identifying cracks In floor or walls of the tank may not be possible at that time.The dispersal cell(s) <br /> shall be visually Inspected to check the effluent levels In the observation pipes and to check for any pending of effluent on the ground surface.The <br /> pending of effluent on the ground surface may Indicate a failing condition and requires the Immediate notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum in any treatment tank equals one-third(1/3)or more of the tank volume,the entire contents of the <br /> tank shall be removed by a Septage Servicing Operator and disposed of In accordance with chapter NR 113,Wisconsin Administrative Code, <br /> 3/8/20 10•POW TSMGT plan.do c <br />