|
Help
|
About
|
Sign Out
Home
Browse
Search
DCPZP-2015-00188
DaneCounty-Planning
>
Zoning
>
1 Permits
>
2010s
>
2015
>
DCPZP-2015-00188
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/30/2015 12:22:23 PM
Creation date
4/28/2015 11:37:04 AM
Metadata
Fields
Template:
Zoning Permits
AccelaLink
DCPZP-2015-00188
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
° Public Health <br /> MADISON Page of&DANE COUNTY — — <br /> HeattlYieoPle aniPlatla POWTS OWNER'S MANUAL&MANAGEMENT PLAN <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> Owner: AL-13 -C�T Tank Manufacturer: }4.? L&.. ❑NA <br /> [Septic 0 Dose 0 Holding Volume gal <br /> Permit 7 POWTS# (Taank Manufa. - . .M ❑NA <br /> 0 Septic V. I. - 0 Holding Volume Lo6.v gal <br /> DESIGN PARAMETERS Vertical D' n .'-Tank Bottom(s)to Service Pad:/5- ft <br /> Number of Bedrooms: 4/ 0 NA Horizontal Distance Tank(s)to Service Pad: '/Si7 ff <br /> Number of Public Fatality Units: 0 NA Specific servicing mechanics must be provide if vertical is>15 feet or ff <br /> Estimated(average)Flow: e-7/0e, horizontal is>150-feet Specific instructions on plan addendum_ <br /> Design(peak)Flow=estimated x 1.5: ('oo gat/day <br /> In Situ Soil Application Rate: gal/day/ffz Effluent Filter Manufacturer 1:)/2-&/0 Co 0 NA <br /> Standard Domestic Influent/Effluent Monthly average Effluent Filter Model- FT 8 <br /> Fats,Oil&Grease(FOG) 530 mg/L Pump Manufacturer: G D Gc i./)$ 0 NA <br /> Biochemical Oxygen Demand(BODs) 520 mg/L 0 NA Pump Model- rp v$7/4G <br /> Total Suspended Solids(TSS) 5150 mg/L Pleb edbllent Unit <br /> High Strength Influent/Effluent Monthly average Manufacturer: <br /> Fats,Oil&Grease(FOG) >30 rrig/L 0 Mechanical Aeration 0 Peat Filter <br /> Biochemical Oxygen Demand(BODs) >220 mg/L T.NA 0 Disinfection 0 Wetland 0 NA <br /> Total Suspended Solids{TSS) >150 mg/L / 0 Sand/Gravel Filer 0 Other: <br /> Pretreated Effluent Monthly average Soil Absorption System <br /> Biochemical Oxygen Demand(GODS) 530 mg/L yKln-Ground(gravity) ❑In-Ground(pressure) 0 NA <br /> Total Suspended Solids(TSS) 530 mg/L }ANA ❑At-Grade ❑Mound <br /> Fecal Coliifoan(geometric mean) 510'cfu/100m1 / ❑Drip-Line ❑Other: <br /> Maximum Effluent Particle Size: VS in dia. 0 NA <br /> Other: 7NA Other: 0 NA <br /> MAINTENANCE SCHEDULE <br /> Service Event Service Frequency <br /> Pump out contents of tank(s) I 0 When combined sludge and scum equals one-third(1/3)of tank volume. <br /> ❑When the high water alarm is activated. <br /> Inspect condition of tank(s) At least once very 3 years_ 0 NA <br /> Inspect dispersal cells(s) At least once very 3 years_ - 0 NA <br /> Clean effluent filter - V ft/ 0 NA <br /> Inspect pump,pump controls&alarm (,.. 0 tc.� ^��/.f ��w,r�� 0 NA <br /> ls <br /> Flush laterals and pressure test / 0 NA <br /> Other: 0 NA <br /> Other: 0 NA <br /> MAINTENANCE INSTRUCTIONS <br /> Inspections of tanks and dispersal cells shall be made by an individual canying one of the following ice uses or certifications:Master Plumber,Master <br /> Plumber Restricted Sewer,POWTS Inspector,POWTS Maintainer,Septage Servicing Operator(pumper).Tank inspections must include a visual <br /> inspection of the tank(s)to identify any missing or broken hardware,identify any cracks or leaks,measure the volume of combined sludge and scum and <br /> a check for any back up or ponding of effluent on the ground surface.If the volume of sludge and scum is less than one-third(1/3)of the timid volume <br /> of the tank,the tank does not need to be pumped and identifying cracks in floor or walls of the tank may not be possible at that&are.The dispersal cell(s) <br /> shall be visually inspected to check the effluent levels in the observation pipes and to check for any pending of effluent on the ground surface.The <br /> pending of effluent on the ground surface may indicate a falling condition and requires the immediate notfication of the local regulatory authorfty. <br /> When the combined acaanulation of sludge and scum in any treatment tank equals one-third(1/3)or more of the tank volume,the entire contents of the <br /> tank shall be removed by a Septage Servicing Operator and disposed of in accordance with chapter NR 113,Wisconsin Administrative Code. <br /> 5mazolo-rovrstdaroan aoc <br />
The URL can be used to link to this page
Your browser does not support the video tag.