Laserfiche WebLink
`Public Health <br /> • MADISON t D:-:NE col . , Page of <br /> iieaItiy Y012 runaplacek POWTS OWNER'S MANUAL &MANAGEMENT PLAN <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> [Owner. . rr// Tank Manufacturer: Miele}0 E 0 NA <br /> TI M(0714 N £ I� 1 X11.c. i.1 CC.t1212A.N !�Septic 0 Dose 0 Holding Volume 1 000 gy` <br /> Permit j POWTS# Tank Manufacturer: M Aro g ❑NA <br /> 11 ❑Septic E l Dose 0 Holding Volume CI SO gal <br /> DESIGN PARAMETERS Vertical Distance Tank Bottom(s)to Service Pad: 4 l S ft <br /> Number of Bedrooms: 3 0 NA Horizontal Distance Tank(s)to Service Pad: 4-1 SO ft <br /> Number of Public Facility Units: 0 NA Specific servicing mechanics must be provide if vertical is>15 feet or if <br /> Estimated(average)Flow: `;00 gal/day horizontal is>150 feet Specific instructions on plan addendum_ <br /> Design(peak)Flow=estimated i.5 A So gay <br /> In Situ Soil Application Rate: gaUdayJft? Effluent Filter Manufacturer 02,Et CO 0 NA <br /> Standard Domestic lnfluent/Effluent Monthly average Effluent Filter Model: F T ' <br /> Fats,Oil&Grease(FOG) s30 mg/L Pump Manufacturer. 6W(,/X ❑NA <br /> Biochemical Oxygen Demand(BOD3) 420 mg/L 0 NA Pump Model �L�„ <br /> Total Suspended Solids(TSS) x150 mg/L Pretreatment Unit <br /> High Strength Influent/Effluent Monthly average <br /> Manufacturer Fats,Oil&Grease(FOG) >30 mg/L Mechanical Aeration ❑Peat Fitter I 1 <br /> Biochemical Oxygen Demand(BODs) >220 mg/L ( NA L7 Disinfection 0 Wetland ( NA <br /> Total Suspended Solids ITSS) >150 mg/L ❑Sand/Gravel Filter r <br /> 0 Other i <br /> Pretreated Effluent Monthly average Soil Absorption System <br /> Biochemical Oxygen Demand(BODs) 0 mg/L pin-Ground(gravity) ❑In Ground(pressure) [j NA <br /> Total Suspended Solids(TSS) 530 mall NA At-Grade 0 Mound <br /> Feral Cofiform(geometric mean) s104 ciu/100m1 0 Drip-Line 0 Other: i <br /> r <br /> Maximum Effluent Particle Size: 118 in die. Ll NA 1 I <br /> I Other. [ NA Other: NAI <br /> I I <br /> MAINTENANCE SCHEDULE - <br /> Service Event I Service Frequency <br /> Pump out contents of tank(s) 11gi When combined sludge and scum equals one-third(1/3)of tank volume. <br /> 1 When the high water alarm is activated_ <br /> inspect condition of tank(s) I At least once very 3 years. 0 NA <br /> inspect dispersal cells(s) I At least once very 3 years_ - 0 NA I <br /> Clean effluent triter I gel4i2,t.y 0 NA <br /> inspect pump,pump controls&alarm NJ[.F...644.Ptk ,P go / A i.,a i2Mt ED - 0 NA <br /> Flush laterals and pressure test I 0 NA l <br /> Other I 0 NA I <br /> Other: 1 0 NA( <br /> MAINTENANCE INSTRUCTIONS <br /> inspections of tanks and dispersal cells shall be made by an individual carrying one of the following licenses or certifications:Master Plumber,Master <br /> Plumber Restricted Sewer, POWTS inspector, POWTS Maintainer,Septage Servicing Operator(pumper).Tank inspections must include a visual <br /> inspection of the tank(s)to identify any missing or broken hardware,identify any aadcs or leaks,measure the volume of combined sludge and scum end <br /> a check for any back up or ponding of effluent on the ground surface.If the volume of sludge and scum is less than one—third(113)of the liquid volume <br /> of the tank,the tank does not need to be pumped and identifying cracks in floor or walls of the tank may not be possible at that lime.The dispersal cell(s) <br /> shall be visually inspected to check the effluent levels in the observation pipes and to check for any ponding of effluent on the ground surface.The <br /> ponding of effluent on the ground surface may indicate a failing condition and requires the immediate notification of the local regulatory authority_ <br /> When the combined accumulation of sludge and scum in any treatment tank equals one-third(113)or more of the tank volume,the entire contents of the <br /> tank shall be removed by a Septage Servicing Operator and disposed of in accordance with chapter NR 113,Wisconsin Administrative Code. <br /> 318/2010POwrsse Flandoa <br />