|
Help
|
About
|
Sign Out
Home
Browse
Search
DCPZP-2015-00476
DaneCounty-Planning
>
Zoning
>
1 Permits
>
2010s
>
2015
>
DCPZP-2015-00476
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/16/2015 12:07:44 PM
Creation date
7/7/2015 2:20:41 PM
Metadata
Fields
Template:
Zoning Permits
AccelaLink
DCPZP-2015-00476
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ii;i1 ' , <br /> ':ip:'.Public Health <br /> ' MADISON&DANE COUNTY Page Ide of <br /> Healthy people and placer POWTS OWNER'S MANUAL& MANAGEMENT PLAN <br /> • <br /> FILE INFORMATION - SYSTEM SPECIFICATIONS <br /> Owner; Tank Manufacturer: /47(001_e•-• ❑NA <br /> !'o�/�i� b��q . ii--z._,) G r Geptic.0.Dose.. ❑Holding Volume.. /gi�G gal <br /> Permit: POWTS# Tank Manufacturer: (I7e&ze. . $ ❑NA <br /> ' ❑Septic Dose. ❑ aiding Volume o'd gal <br /> ;;DESIGN PARAMETERS Vertical Distance Tank Bottom(s)to Service Pad: /0 ft <br /> • Number of Bedrooms: '/ ❑NA Horizontal Distance Tank(s)to Service Pad: /`t) ft <br /> Number.of Public Facility.UnItai ❑NA Specific servicing mechanics must be provide If vertical Is>15 feet or If <br /> Estimated(average)Flow: >f�Z .gal/day • horizontal Is>150 feet.Specific Instructions on plan addendum. • <br /> Design(peak)Flow.=estimated x 1.5: - 4ew . gal/day . <br /> In Situ Soil Application Rate: O, . gal/day/ft' Effluent Filter Manufacturer O r 4 n/�.a ❑NA <br /> Standard Domestic Influent/Effluent Monthly average Effluent Filter Model: .77 o Pte .- / +( 13^ 4 S a • <br /> . Fats;oil&Grease(FOG) 53Q mg/t... . . .. . : Pump Manu(actur.Qrt . ,e,4,1 14, . ❑NA. <br /> Biochemical Oxygen Demand(BOD5) 5220 mg/L ❑NA Pump Model: d>0 y f) - . <br /> Total Suspended Solids(TSS) 5150 mg/L Pretreatment Unit <br /> High Strength.Influent/Effluent . Monthly average Manufacturer: ' <br /> Fats,Oil&Grease(FOG) >30 mg/L ❑Mechanical Aeration ❑Peat Filter <br /> Biochemical Oxygen.Demand(BODs) >220 mg/L ❑NA . - ❑Disinfection ❑Wetland <br /> Total Suspended Solids(TSS) >150 mg/t. • ❑Sand/Gravel Filter ❑Other: •• <br /> Pretreated Effluent Monthly average Soil Absorption System . • - • <br /> Biochemical Oxygen Demand(BOD,) 530 mg/L "Ground(gravity) ❑In-Ground(pressure) . ❑NA <br /> Total Suspended Solids(TSS) 530.mg/L ❑NA ❑At-Grade ❑Mound <br /> Fecal Coiiform(geometric mean) 5104 cfu/100m1 ❑Drip-Line ❑Other: <br /> Maximum Effluent Particle Size: • .1/8 In dia. ❑NA .. . • . . <br /> Other: ❑NA Other: • . • . - 0 NA <br /> MAINTENANCE SCHEDULE • <br /> • .. • Smiles Event • . : _ . . .. Service Frequency • .. • • • <br /> Pump out contents Of tanks) hen combined sludge and scum equals one-third(1/3)of tank volume. . <br /> RWhen the high water alarm Is.activated._ ., <br /> Inspect,conditioo of tank(s) , At least once very 3 years. , ❑NA <br /> -inspect dispersal,cells(s) _ • At least once very 3 years: - . . ❑NA• <br /> Clean effluent filter AS • k• Y c ❑NA <br /> 'V <br /> Inspect pump,pump controls &alarm 0/40,4 71k4. te 5q:, ❑NA <br /> • <br /> • <br /> Flush laterals and pressure test ' ❑NA <br /> Other: ❑NA <br /> Other: - • ❑NA <br /> MAINTENANCE INSTRUCTIONS - . <br /> Inspections of tanks and dispersal cells shall be made by an Individual carrying one of the following licenses or certifications:Master Plumber, Master <br /> Plumber Restricted Sewer, POWTS Inspector, POWTS Maintainer, Septage Servicing Operator (pumper). Tank Inspections must Include a visual <br /> inspection of the tanks)to identify any missing or broken hardware,Identify any cracks or leaks;measure the volume Of combined sludge and scum and <br /> a check for any back up or pending of effluent on the ground surface.If the volume of sludge and scum Is less than one—third(1/3)of the liquid volume <br /> of the tank,the tank does not need to be pumped and Identifying cracks in floor or walls of the tank may not be possible at that time.The dispersal cell(s) <br /> shall be visually inspected to check the effluent levels In the observation pipes and to check for any ponding of effluent on the ground surface.The <br /> pending of effluent on the ground surface may Indicate a falling condition and requires the Immediate notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum In any treatment tank equals one-third(1/3)or more of the tank volume,the entire contents of the <br /> tank shall be removed by a Septage Servicing Operator and disposed of In accordance with chapter NR 113,Wisconsin Administrative Code. <br /> 3/8/20 10•PO W TSMG Tplan.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.