Laserfiche WebLink
START UP AND OPERATION Page t9 of <br /> For new coistruction, prior to use of the POWTS check treatment tank(s) for the presence of painting products, solvents or other <br /> chemicals or sediment that may impede the treatment process and/or damage the soil absorption system. If high concentrations are <br /> detected have the contents of the tank(s)removed by a:Septage Servicing Operator(pumper)prior to use. <br /> Pump tanks may fill above normal highwater levels prior to startup or due to pump failures. Start up or restoration of power under these <br /> conditions is not recommended, as the excess wastewater will be discharged to the soil absorption system in one large dose causing an <br /> overload that may result in the backup or surface'discharge of effluent and damage to the system. To avoid this situation have the <br /> contents of the pump tank removed by a Septage Servicing Operator(pumper)prior to restoring power to the pump or contact a Plumber <br /> or POWTS Maintainer to assist in manually operating the pump controls until normal effluent levels are restored within the pump tank. <br /> System star' up shall not occur when soil conditionsiare;frozen at the infiltrative surface. <br /> Do not drive or park vehicles over tanks or the soil!absorption system. Do not drive or park over, or otherwise disturb or compact,the <br /> area within 15 feet down slope of any mound or at-grade soil absorption area. <br /> Reduction or elimination of the following from the wastewater stream may improve the performance and prolong the life of the treatment <br /> tanks and soi absorption system: acids, antibiotics, baby wipes, cigarette butts, condoms, cotton swabs, degreasers, dental floss, <br /> diapers, disinfectants, fats, foundation drain (sump pump) discharge, fruit and vegetable peelings, gasoline, greases, herbicides, meat <br /> scraps,medications,oils,painting products, pesticides,sanitary napkins,solvents,tampons,and water softener brine discharge. <br /> ABANDONMENT <br /> When the POWTS fails and/or is permanently taken out of service the following steps shall be taken to insure that the system is properly <br /> and safely abandoned in compliance with s.Comm 83.33,Wisconsin Administrative Code: <br /> • All piping to tanks, pits and other soil absorption systems shall be disconnected and the abandoned pipe openings sealed. <br /> • Tha contents of all tanks and pits shall be removed and properly disposed of by a Septage Servicing Operator(pumper). <br /> • After pumping, all tanks and pits shall be excavated and removed or their covers removed and the void space filled with soil, <br /> gravel or another inert solid material. <br /> CONTINGENICY PLAN <br /> If the POWTS fails and cannot be repaired the following measures have been, or must be taken, to provide a code compliant <br /> replacement system: <br /> ❑ A suitable replacement area has been evaluated and may be utilized for the location of a replacement soil absorption system. <br /> The replacement area should be protected from disturbance and compaction and should not be infringed upon by required <br /> setbacks from existing and proposed structure, lot lines and wells. Failure to protect the replacement area will result in the need <br /> for a new soil and site evaluation to establish a suitable replacement area. Replacement systems must comply with the rules in <br /> effect at the time of their permit issuance. <br /> ❑ A st,itable replacement area is not available due to setback and/or soil limitations. If the soil absorption system cannot be <br /> rehabilitated and barring advances in POWTS technology,a holding tank may be installed as a last resort. <br /> ('The site has not been evaluated to identify a suitable replacement area. Upon failure of the POWTS a soil and site evaluation <br /> mus be performed to locate a suitable replacement area. If no replacement area is available a holding tank may be installed as a <br /> last resort to replace the failed POWTS. <br /> ❑ Mould and at-grade soil absorption systems may be reconstructed in place following removal of the biomat at the infiltrative <br /> surface. Reconstructions of such systems must comply with the rules in effect at that time. <br /> WARNING TREATMENT TANKS, PUMP TANKS, AND HOLDING TANKS MAY CONTAIN POISONOUS GASSES OR LACK <br /> !, SUFFICIENT OXYGEN TO SUSTAIN LIFE. NEVER ENTER ANY TANK UNDER ANY CIRCUMSTANCE. DEATH MAY <br /> ` RESULT. ESCAPE OR RESCUE FROM THE INTERIOR OF A TANK MAY NOT BE POSSIBLE. <br /> v • <br /> ADDITIONAL INSTRUCTIONS: f • <br /> T�� Sr=1�'ie SitCltt Id e_ pLuved AT Thf rnJD of The(Akita SEASen,1 "re ioieeveivr <br /> Fi2CEza1 4 4 ea,v-reA rs Dti ..ij The i livTec FF2pm Now tnse. <br /> POWTS INS—ALLER POWTS MAINTAINER <br /> Name g,f/RN' rL � ! <br /> f, 6 Name 15Rl4lf JsiNJ,9 <br /> Phone(9 621- U 31 ., 44 3'7 Phone 6 0 1/3 a L{(0$7 <br /> SEPTAGE SERVICING OPERATOR(PUMPER) LOCAL REGULATORY AUTHORITY <br /> Name Name OAAj E l a (4 j T Y Exit), 1'4!`A LT H <br /> Phone Phone G ay- v2 -G$/5 <br /> This document was drafted by the staffs of the Green Lake, Marquette and Waushara County POWTS regulatory agencies in compliance with sections <br /> Comm 83.22(2(b)(1)(d)&(f)and 83.54(1),(2)&(3),Wisconsin Administrative Code. <br />