'*':' Public Health �" <br /> NtADISON&DANE COUNTY Page fy of / <br /> KKalthypeopla and placer POWYS OWNER'S MANUAL & MANAGEMENT PLAN <br /> 'FiLE INFORMATION - SYSTEM SPECIFICATIONS <br /> Owned Tank Manufacturer: Meade <br /> .-90 5 k - ❑NA <br /> �a•�) �!"c J — ®Septic E}Dose—❑ Holding Volume l� G gal <br /> Permit: PO��/TS# ( Tank Manufacturer: 7eeaAe ❑NA <br /> ❑Septic ]Dose ❑ Holding Volume �?00 gal <br /> ;f-DESIGN PARAMETERS Vertical Distance Tank Bottom(s)to Service Pad: /4/ _ft <br /> Number of Bedrooms: `f ❑NA Horizontal Distance Tank(s)to Service Pad: /.O ft <br /> Number of Public Facillty.Units ❑ NA Specific servicing mechanics must be provide If vertical is>15 feet or if <br /> Estimated(average)Flow: i-1(>0 gal/day horizontal Is>150 feet.Specific Instructions on plan addendum. <br /> Design (peak)Flow.=estimated x 1.5: b 0 b gal/day . - <br /> In Situ Soil Application Rate: r .( . gal/day/ft= Effluent Filter_Manufacturer O r t.nice, ❑NA <br /> Standard Domestic influent/Effluent Monthly average _Effluent Filter Model: 17 It t1).- f l( 13-~ 4-so • <br /> Fats;011&Grease(FOG),s3Q mg/L• . . , . : Pump.Manufacturer:. 6vu/&5 ❑NA <br /> • <br /> Biochemical Oxygen Demand(BODE) 5220 mg/L ❑NA Pump Model: 6 in q// <br /> Total Suspended Solids(TSS) 5150 mg/L Pretreatment Unit <br /> High Strength.Influent/Effluent Monthly average Manufacturer: <br /> Fats,011&Grease(FOG) >30 mg/L ❑Mechanical Aeration ❑Peat Filter <br /> Biochemical Oxygen Demand(BOD5) >220 mg/L 2 NA • ❑Disinfection ❑Wetland [ANA <br /> Total Suspended Salids(TSS) >150.mg/L - ❑Sand/Gra'el Filter ❑Other <br /> Pretreated Effluent _ Monthly average • Soil Absorption System - - <br /> Biochemical Oxygen Demand(3005) 530 mg/L • El in-Ground(gravity) ,. ❑In-Ground(pressure) ❑NA <br /> Total Suspended Solids(TSS) 530.mg/L 2 NA ❑At-Grade ❑Mound <br /> Fecal Coliform(geometric mean) 510+cfu/100m1 ❑Drip-Line El Other: <br /> Maximum Effluent Particle Size: • :/din dla. ❑ NA .. . • _ <br /> Other: - _ ❑NA " Other: • . <br /> • . ❑CIA <br /> • <br /> MAINTENANCE SCHEDULE <br /> .. Service Event - • .. - . - _. Service-Frequency . . . <br /> ❑When combined sludge.and scum equals one-third 1/3 of tank volume, <br /> Pump out <br /> contents of tank(s) <br /> ( ) <br /> ❑When the high water alarm is.activated., . <br /> Inspect,condition of tank(s) , At least once very 3 years. ❑NA <br /> Inspect disp' ., <br /> ersal cells(s) .. • At least once very 3 years: - ❑NA <br /> Clean effluent filter 4--1- /eu 5,f ante a yea"' ❑NA <br /> Inspect pump, pump controls&alarm (u h e H f),„,../.,d • ❑NA <br /> Flush laterals and pressure test ' ffl NA <br /> Other: �'NA <br /> Other: - 2 NA" <br /> MAINTENANCE INSTRUCTIONS - <br /> Inspections of tanks and dispersal cells shall be made by an Individual carrying one of the following licenses or certifications:Master Plumber, Master <br /> Plumber Restricted Sewer, POWYS inspector, POWTS Maintainer, Septage Servicing Operator (pumper). Tank Inspections must Include a visual <br /> Inspection of the tank(s)to identify any missing or broken hardware,Identify any cracks or leaks;measure the volume of combined sludge and scum and <br /> a check for any back up or ponding of effluent on the ground surface.If the volume of sludge and scum Is less than one–third(1/3)of the liquid volume <br /> of the tank,the tank does not need to be pumped and Identifying cracks In floor or walls of the tank may not be possible at that time.The dispersal cell(s) <br /> shall be visually Inspected to check the effluent levels In the observation pipes and to check for any ponding of effluent on the ground surface.The <br /> pending of effluent on the ground surface may indicate a falling condition and requires the Immediate notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum in any treatment tank equals one.third(1/3)or more of the tank volume,the entire contents of the <br /> tank shall be removed by a Septage Servicing Operator and disposed of in accordance with chapter NR 113,Wisconsin Administrative Code. <br /> 3/9/2010•POWTSMOTplan.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.