Laserfiche WebLink
Public Health Page�f4of <br /> Hcohf v people and places POWTS OWNER'S MANUAL & MANAGEMENT PLAN <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> Owner: Tank Manufacturer: ❑ NA <br /> E Septic ❑ Dose ❑ Holding Volume gal <br /> Permit: POWTS#t Tank Manufacturer: 7- ❑ A <br /> N <br /> ❑ Septic ['Dose ❑ Holding Volume -SSv gal <br /> DESIGN PARAMETERS Vertical Distance Tank Bottom(s)to Service Pad: /5 it <br /> Number of Bedrooms: gs NA Horizontal Distance Tank(s)to Service Pad: 5l' ft <br /> Number of Public Facility Units: ® NA Specific servicing mechanics must be provide if vertical is>15 feet or if <br /> Estimated(average)Flow: jao gal/day horizontal is>150 feet.Specific instructions on plan addendum. <br /> Design(peak)Flow= estimated x 1.5: /5 gal/day <br /> In Situ Soil Application Rate: 17- C gal/day/ft2 Effluent Filter Manufacturer .Sin�T GZ/ ❑ NA <br /> Standard Domestic Influent/Effluent Monthly average Effluent Filter Model: <br /> Fats.Oil&Grease(FOG) :-30 mg/L Pump Manufacturer. En ❑ NA <br /> Biochemical Oxygen Demand(BOOS) :5220 mg/L ❑ NA Pump Model: ? <br /> Total Suspended Solids(TSS) 5150 mg/L Pretreatment Unit <br /> High Strength Influent/Effluent Monthly average Manufacturer: <br /> Fats.Oil&Grease(FOG) >30 mg/L ❑Mechanical Aeration ❑Peat Filter <br /> Biochemical Oxygen Demand(BODS) >220 mg/L ®NA ❑Disinfection El Wetland {ANA <br /> Total Suspended Solids(TSS) >150 mg/L ❑Sand/Gravel Filter ❑Other: <br /> — <br /> Pretreated Effluent Monthly average Soil Absorption System <br /> Biochemical Oxygen Demand(BOD5) 5530 mg/L ❑In-Ground(gravity) ❑In-Ground(pressure) ❑ NA <br /> Total Suspended Solids(TSS) 530 mg/L at NA rg At-Grade ❑Mound <br /> Fecal Coliform(geometric mean) 510"cfu/100mI 0 Drip-Line ❑Other: <br /> Maximum Effluent Particle Size: 1/8 in dia. ❑NA <br /> Other: E NA Other: NA <br /> MAINTENANCE SCHEDULE <br /> Service Event Service Frequency <br /> Pump out contents of tank(s) ®When combined sludge and scum equals one-third(1/3)of tank volume. <br /> at When the high water alarm is activated. <br /> Inspect condition of tank(s) At least once very 3 years. ❑ NA <br /> Inspect dispersal cells(s) At least once very 3 years. ❑ NA <br /> Clean effluent filter ❑ NA <br /> Inspect pump,pump controls 8,alarm ❑NA <br /> Flush laterals and pressure test ❑NA <br /> Other: jg NA <br /> Other: ® NA <br /> MAINTENANCE INSTRUCTIONS <br /> Inspections of tanks and dispersal cells shall be made by an individual carrying one of the following licenses or certifications:Master Plumber, Master <br /> Plumber Restricted Sewer, POWTS Inspector, POWTS Maintainer, Septage Servicing Operator (pumper). Tank inspections must include a visual <br /> inspection of the tank(s)to identify any missing or broken hardware,identify any cracks or leaks,measure the volume of combined sludge and scum and <br /> a check for any back up or ponding of effluent on the ground surface.If the volume of sludge and scum is less than one-third(1/3)of the liquid volume <br /> of the tank,the tank does not need to be pumped and identifying cracks in floor or walls of the tank may not be possible at that time.The dispersal cell(s) <br /> shall be visually inspected to check the effluent levels in the observation pipes and to check for any ponding of effluent on the ground surface. The <br /> ponding of effluent on the ground surface may indicate a failing condition and requires the immediate notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum in any treatment tank equals one-third(1/3)or more of the tank volume,the entire contents of the <br /> tank shall be removed by a Septage Servicing Operator and disposed of in accordance with chapter NR 113,Wisconsin Administrative Code. <br /> U5.2n I 0-POW T$t9GTolen doc <br />