|
Help
|
About
|
Sign Out
Home
Browse
Search
DCPZP-2015-00737
DaneCounty-Planning
>
Zoning
>
1 Permits
>
2010s
>
2015
>
DCPZP-2015-00737
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/25/2015 11:34:46 AM
Creation date
9/22/2015 11:24:41 AM
Metadata
Fields
Template:
Zoning Permits
AccelaLink
DCPZP-2015-00737
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Page 1of2 <br /> POWTS OWNER'S MANUAL&MANAGEMENT PLAN <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> Owner: TREVOR&SARAHBERCEAU Tank Manufacturer: DALMARAY <br /> © Septic ❑Dose ❑Holding Volume 1000 gal <br /> Permit: POWTS# Tank Manufacturer: DALMARAY <br /> ❑ Septic ©Dose ❑Holding Volume 600 gal <br /> DESIGN PARAMETERS Vertical Distance Tank Bottom(s)to Service Pad: <15'ft <br /> Number of Bedrooms: 3 Horizontal Distance Tank(s)to Service Pad: <150'ft. <br /> Number of Public Facility Units: N/A Specific servicing mechanics must be provided if vertical is>15 ft. <br /> Estimated(average)Flow: 300 gal/day or if horizontal is>150 ft.Specific instructions on plan addendum. <br /> Design(peak)Flow=estimated x 1.5: 450 gal/day <br /> In Situ Soil Application Rate: 0.6 gal/day/ft' Effluent Filter Manufacturer and Model: <br /> Standard Domestic Influent/Effluent Monthly average SIM/TECHSTF100 OR EQUIVALENT <br /> Fats,Oil&Grease(FOG) 5 30 mg/L Pump Manufacturer and Model: <br /> Biochemical Oxygen Demand(8005) 5 220 mg/L GOULDS WEO3L <br /> Total Suspended Solids(TSS) 5 150 mg/L Pretreatment Unit <br /> High Strength Influent/Effluent Monthly average Manufacturer: <br /> Fats,Oil&Grease(FOG) >30 mg/L ❑ Mechanical Aeration❑ Peat Filter <br /> Biochemical Oxygen Demand(BODS) >220 mg/L N/A ❑ Disinfection ❑ Wetland N/A <br /> Total Suspended Solids(T55) >150 mg/L ❑ Sand/Gravel Filter ❑ Other: <br /> Pretreated Effluent Monthly average Soil Absorption System <br /> Biochemical Oxygen Demand(BOD5)5 30 mg/L © In-ground(gravity) ❑ In-ground(pressure) <br /> Total Suspended Solids(TSS)55 30 mg/L N/A ❑ At-grade ❑ Mound <br /> Fecal Coliform(geometric mean) 5104 cfu/100ml ❑ Drip-line ❑ Other: <br /> Maximum Effluent Particle Size: 1/8 in.dia. <br /> Other: N/A Other: N/A <br /> MAINTENANCE SCHEDULE <br /> Service Event Service <br /> Pump out contents of tank(s) When combined sludge and scum equals one-third(1/3)of tank volume. <br /> When the high water alarm is activated. <br /> Inspect condition of tank(s) At least once every 3 years <br /> Inspect dispersal cell(s) At least once every 3 years <br /> Clean effluent filter Every year or as needed within a 3 year interval <br /> Inspect pump,pump controls&alarm At least once every 3 years <br /> Flush laterals and pressure test N/A <br /> Other: N/A <br /> Other: N/A <br /> MAINTENANCE INSTRUCTIONS <br /> Inspection of tanks and dispersal cell(s)shall be made by an individial carrying one of the following licenses or certifications:Master Plumber,Master <br /> Plumber Restricted Sewer,POWTS Inspector,POWTS Maintainer,Septage Servicing Operator(pumper).Tank inspections must include a visual <br /> inspection of the tank(s)to identify any missing or broken hardware,identify any cracks or leaks,measure the volume of combined sludge and scum <br /> and a check for any backup or ponding of effluent on the ground surface.The dispersal cell(s)shall be visually inspected to check the effluent levels in <br /> the observation pipes and to check for any ponding of effluent in the ground surface.The ponding of effluent on the ground surface may indicate a <br /> failing condition and require the immediate notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum in any treatment tank equals one-third(1/3)or more of the tank volume,the entire contents of <br /> the tank shall be removed by a Septage Servicing Operator and disposed of in accordance with chapter NR 113,Wisconsin Administrative Code. <br /> All other services,including but not limited to the servicing of effluent filters,mechanical or pressurized components,pretreatment units,and any <br /> servicing at intervals of 12 months,shall be performed by a certified POWTS Maintainer. <br /> A service report shall be provided to the local regulatory authority within 30 days.of completion of any service event. <br /> RI' <br />
The URL can be used to link to this page
Your browser does not support the video tag.