|
Help
|
About
|
Sign Out
Home
Browse
Search
DCPZP-2015-00723
DaneCounty-Planning
>
Zoning
>
1 Permits
>
2010s
>
2015
>
DCPZP-2015-00723
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/2/2015 10:30:20 AM
Creation date
9/30/2015 12:32:44 PM
Metadata
Fields
Template:
Zoning Permits
AccelaLink
DCPZP-2015-00723
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
11;11 <br /> ':°` ''Public Health <br /> MADISON&DANE COUNTY Page 7aF <br /> Healthy people and places :POWYS OWNER'S MANUAL& MANAGEMENT PLAN <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> Owner: "�' Tank Manufacturer: /jfe��/ ❑NA <br /> k#-\ ' `�� �r -Septic.❑.Dose-- ❑Holding . Volume. 1144 gal <br /> Permit: iPOWTS# Tank Manufa turer. <br /> I ilea.d� ❑NA <br /> 0 Septic Dose. 0 Holding Volume •*CO gal <br /> ? DESiGN PARAMETERS Vertical Distance Tank Bottoms)to Service Pad: I.Q. <br /> • Number of Bedrooms: f ft <br /> ❑NA Horizontal Distance Tanks)to Service Pad: /l6 ft <br /> Numbet-of Public Facility.Units? ❑NA Specific servicing mechanics must be provide If vertical is>15 feet or if <br /> Estimated(average)Flow: lied, horizontal 18).150 feet.Specific Instructions on plan addendum. <br /> Design(peak)Flow.=estimated x 1.5: -VDU . gaUday <br /> In Situ Soil Application Rate; ,0 . gal/da /ft= ❑NA <br /> � Y Effluent Fliter Manufacturer Q r`s=nl(a <br /> Standard Domestic Influent/Effluent 'Monthly average Effluent Filter Model: .77"c)(`a . 14B- 1$0 <br /> • Fats).Oil&Grease(FOG)-530 rpglf... . . . Pump.Manufactyrgr, e./ter- <br /> Biochemical Oxygen Demand(13O0s) 5220 mg/L 0 NA Pump Model: !Y. ❑NA <br /> Total Suspended Solds(rSS) 5150 mg/L Pretreatment Unit <br /> High Strength-influent/Effluent . Monthly average Manufacturer: V <br /> Fafs,Olt&Grease(FOG) >30 mg/L 0 MechanIcai Aeration ❑Peat Filter <br /> Biochemical Oxygen_Demand(BOOS) >220 mg/L tL NA - 0 Dfstnfectton ,(N, <br /> o 0 [y-��A <br /> Total Suspended Saida(TSS) >130-tng/L - ❑Sand/Gravel Filter <br /> 0 Other: <br /> Pretreated Effluent Monthly average Soil Absorption System - • •• ' " <br /> Biochemical Oxygen Demand(BOD5) 530 mg/L ❑in-Ground(gravity) ❑in-Ground <br /> Total uspended Solids(TSS) 530.mg/L (pressure) Li NA <br /> Suspended ❑At-Grade 40-Mound <br /> Fecal Conform(geometric mean) 5104 cfu/100m1 ❑Drip-Line <br /> V ❑Other: <br /> Maximum Effluent Particle Size: . .1/8 in dia. 0 NA •- . <br /> Other: ❑NA Other: ' . <br /> 0 N <br /> • <br /> MAINTENANCE SCHEDULE <br /> - .. - . Service Event - • , : .. .. V Service Frequency . . V <br /> Pump out contents of tank(s) t■1 hen combined sludge and scum equals one-Ehlyd(1i3)of tank volume. - - <br /> id When the high water alarm ls"activated. .. - V V <br /> Inspect condltloo of tank(s) At least once very 3 years. ❑NA <br /> Inspect dispersal,cells(s) _ _ ' At least once very 3 years:,. _ _ . ❑NA <br /> Clean•effluent filter zDtvC c V i�A <br /> Inspect pump,pump controls &alarm • <br /> Ct)cm 'Tgs 4 re_ Cr- yiC43 El NA <br /> Flush laterals and pressure test if r- o • 4" • <br /> • 0 NA <br /> Other: <br /> ❑NA <br /> Other. • <br /> 0 N <br /> MAINTENANCE INSTRUCTIONS - - <br /> Inspections of tanks and dispersal cells shall be made by an Individual carrying one of the following licenses or certifications:Master Plumber,Master <br /> Plumber Restricted Sewer, POWYS inspector, POWTS Maintainer, Septage Servicing Operator(pumper). Tank Inspections must Include a visual <br /> Inspection of the tanks)to Identify any missing or broken hardware,identify any cracks or leaks;measure the volume of combined sludge and scum and <br /> a check for any back up or ponding of effluent on the ground surface.If the volume of sludge and scum Is less than one-third(1/3)of the liquid volume <br /> of the tank,the tank does not need to be pumped and identifying cracks in floor or walls of the tank may not be possible at that time.The dispersal cells) <br /> shall be visually inspected to check the effluent levels in the observation pipes and to check for any ponding of effluent on the ground surface.The <br /> ponding of effluent on the ground surface may indicate a falling condition and requires the Immediate notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum In any treatment tank equals one-third(1/3)or more of the tank volume,the entire contents of the <br /> tank shall be removed by a Septage Servicing Operator and disposed of in accordance with chapter NR 113,Wisconsin Administrative Code, <br /> 318/2010.POWTSMOTplen,doc <br /> Ii <br />
The URL can be used to link to this page
Your browser does not support the video tag.