Laserfiche WebLink
�pART11r DIVISION OF INDUSTRY SERVICES <br /> PO BOX 7162 <br /> 70/ MADISON WI 53707-7162 <br /> �� © \ Contact Through Relay <br /> `5t s http://dsps.wi.gov/programs/industry-services <br /> 7 11 G J www.wisconsin.gov <br /> NJ f <br /> o Scott Walker,Governor <br /> Dave Ross,Secretary <br /> October 15,2015 <br /> CUST ID No. 1028496 ATTN. Buildings&Structures Building Inspector <br /> MICHAEL MCCORMICK BUILDING INSPECTION <br /> ALLIED DESIGN A&E GROUP PC TOWN OF BURKE <br /> 100 S PERSHING PO BOX 110 5365 REINER ROAD <br /> MORTON IL 61550 BURKE WI 53718 <br /> (Please forward a copy of this letter to the fire <br /> department conducting inspections of this project.) <br /> CONDITIONAL APPROVAL <br /> PLAN APPROVAL EXPIRES: 10/15/2017 Identification Numbers <br /> Transaction ID No.2620569 <br /> SITE Site ID No. 818205 <br /> Blue Vista Farm Please refer to both identification numbers, <br /> Wood Dr above,in all correspondence with the agency. <br /> Town of Burke <br /> Dane County <br /> FOR: <br /> Facility:755170 AUTUMN WOOD STORAGE LLC <br /> WOOD DRIVE <br /> Tenant Name or Addn/Alt Description:Unheated,Unattended S-1 Mini Storage Building B-211'X 42' <br /> Object Type:Building ICC Regulated Object ID No.: 1560549 Code Applies Date: 10/06/15 <br /> Major Occupancy:Storage; Type VB Combustible Unprotected class of construction; New plan; 8,862 project sq ft; <br /> Unsprinklered; Occupancy: S-1 Storage Moderate-Hazard <br /> Object Type:Truss,Roof Regulated Object ID No.: 1560550 Code Applies Date: 10/06/15 <br /> The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes <br /> and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner,as defined in <br /> chapter 101.01(10),Wisconsin Statutes,is responsible for compliance with all code requirements. Only those object <br /> types listed above have been approved;other submittals such as plumbing and those listed below under Also Submit, <br /> may also be required. <br /> The following conditions shall be met during construction or installation and prior to occupancy or use: <br /> Reminders <br /> • SPS 361.30—Per page 5 of talcs,sidewall nailers are 2100 MSR SPF*35.5"oc. This was not found on <br /> Sheet S4. <br /> • IBC 2902.1 -Since this building lacks toilet facilities,it is approved as unoccupied storage only. <br /> • IECC 101.5.2/SPS 363.0101 -This building is approved as an unheated storage building. Should the owner <br /> wish to heat or cool this building at a future time,building alteration plans shall be required to be submitted and <br /> conditionally approved. The plans shall demonstrate building envelope compliance. After such action,HVAC <br /> plans would then be required to be submitted and conditionally approved prior to HVAC equipment installation. <br /> • IBC 1108.3-Self-service storage facilities shall provide accessible individual self-service spaces in accordance <br /> with Table 1108.3,with a minimum 5%of the total to be accessible.Accessible individual self-service storage <br /> spaces shall be dispersed throughout the various classes of spaces provided. A storage space is considered <br /> accessible if there is any one of the following: 1)a swing door with a minimum 32"clearance and 6 ft 8 inch <br />