Laserfiche WebLink
Enbridge Energy, LP Hoover & Keith, Inc. <br /> Waterloo Pump Station RN 3083/JN 4796 <br /> Noise Impact Analysis (10/10/14) <br /> shall not be utilized. Each ventilation inlet and exhaust outlet shall assume that the <br /> following sound pressure levels exist inside the pump house building at and adjacent <br /> to the ventilation equipment: <br /> SPLs per Octave-Band Center Fre . &A-Wt. Level <br /> 31.5 63 125 250 500 1000 2000 4000 8000 dBA <br /> 75 80 85 85 85 80 80 75 65 87 <br /> ➢ As a minimum, air-supply fans used for ventilation should include a metal boot <br /> enclosing the fan; a minimum 36-inch length exterior silencer and a weather hood <br /> lined with acoustical insulation. Assuming separate roof exhaust vents will be utilized, <br /> each roof exhaust vent, as a minimum, should include a 36-inch length silencer(i.e., <br /> baffle-type design) mounted between the building surface and vent/hood (i.e., in the <br /> ventilator throat). <br /> 5.2 VFD System Cooling Exhaust Air and associated Components <br /> Air Exhaust System for VFD: It is anticipated that the air exhaust of each VFD cooling <br /> system will be exhausted via an opening located on the ESB building wall (via a louver). <br /> Based on this design, the A-wt. sound level generated from the air exhaust opening of the <br /> VFD air exhaust system (including any noise control) should not exceed 40 dBA at 50 <br /> feet. It is recommended that a 5-ft. length (min.) parallel-baffle silencer should be <br /> installed in-line with the VFD air exhaust ductwork, preferably in the VFD exhaust ducting <br /> located inside the ESB Building. If it is not feasible to insert the recommended silencer <br /> in-line with the interior air exhaust ductwork, the silencer may have to be mounted on the <br /> exterior wall of the air exhaust opening. For reference, the following table lists the <br /> recently-measured A-wt. sound level and unweighted O.B. SPLs at 5 feet and 50 feet <br /> from the air exhaust opening of a typical "modular-type" VFD Building at another <br /> Enbridge pumping station. <br /> Meas'd Sound Levels at 5 Ft. &50 Ft. for VFD Air Exhaust O ening <br /> Distance 31.5 63 125 250 500 1000 2000 4000 8000 A-Wt. <br /> 5 Ft. 76 dB 72 dB 78 dB 72 dB 70 dB 68 dB 68 dB 65 dB 58 dB 74 dBA <br /> 50 Ft. 64 dB 61 dB 65 dB 62 dB 60 dB 57 dB 56 dB 52 dB 46 dB 63 dBA <br /> Other Equipment/Components: The A-wt. sound level of each wall-mounted AC unit <br /> should not exceed 40 dBA at a distance of 50 feet from the equipment during operation. <br /> In addition, for the ESB Building, assuming wall openings will associated with the building <br /> air ventilation system, it may be necessary to employ acoustical-type louvers and/or other <br /> type of noise control measures to reduce the noise of internal equipment(e.g., VFDs, <br /> etc.)that radiates through any building ventilation openings. <br /> -4- <br />