|
Help
|
About
|
Sign Out
Home
Browse
Search
DCPZP-2015-00881
DaneCounty-Planning
>
Zoning
>
1 Permits
>
2010s
>
2015
>
DCPZP-2015-00881
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/3/2015 10:34:09 AM
Creation date
11/2/2015 10:05:57 AM
Metadata
Fields
Template:
Zoning Permits
AccelaLink
DCPZP-2015-00881
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Public Health � 1 1a o1 ,/ <br /> Page/, . <br /> Healthy people and places POWTS OWNER'S MANUAL&MANAGEMENT PLAN <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> Owner: , <br /> 2 Tank Manufacturer: <br /> c ' ❑NA/3?.41 644.ET lk�� Septic ❑Dose ❑Holding Volu me <br /> /3 ,., gal <br /> Permit: POWTS# Tank Manufacturer: *f NA <br /> i ❑Septic ❑Dose ❑Holding Volume gal <br /> DESIGN PARAMETERS Vertical Distance Tank Bottom(s)to Service Pad: %V ft <br /> Number of Bedrooms: / ❑NA Horizontal Distance Tank(s)to Service Pad: Gv ft <br /> Number of Public Facility Units: ®NA Specific servicing mechanics must be provide if vertical is>15 feet or if <br /> Estimated(average)Flow: ° gal/day horizontal s>150 feet Specific instructions on plan addendum. <br /> Design(peak)Flow=estimated x 1.5: 6 v� gal/day <br /> In Situ Soil Application Rate: C7- y gal/day/ft2 Effluent Filter Manufacturer S.T ❑NA <br /> Standard Domestic Influent/Effluent Monthly average Effluent Filter Model: 6-C �1■?' <br /> Fats,Oil&Grease(FOG) 530 mg/L Pump Manufacturer: NA <br /> Biochemical Oxygen Demand(BODS) x220 mg/L ❑NA Pump Model: <br /> Total Suspended Solids(TSS) 5150 mg/L Pretreatment Unit <br /> High Strength Influent/Effluent Monthly average Manufacturer <br /> Fats,Oil&Grease(FOG) >30 mg/L ❑Mechanical Aeration ❑Peat Filter <br /> Biochemical Oxygen Demand(BOOS) >220 mg/L J NA ❑Disinfection ❑Wetland [ NA <br /> Total Suspended Solids(TSS) >150 mg/L ❑Sand/Gravel Filter ❑Other. <br /> Pretreated Effluent Monthly average Soil Absorption System <br /> Biochemical Oxygen Demand(BODS) 530 mg/L In-Ground(gravity) ❑In-Ground(pressure) ❑NA <br /> Total Suspended Solids(TSS) 530 mg/L W.NA ❑At-Grade ❑Mound <br /> Fecal Coliform(geometric mean) 510°cfu/100m1 ❑Drip-Line ❑Other <br /> Maximum Effluent Particle Size: 1/8 in dia. ❑NA <br /> Other fgNA Other. <br /> IS?NA <br /> MAINTENANCE SCHEDULE <br /> Service Event Service Frequency <br /> rig <br /> Pump out contents of lank(s) When combined sludge and scum equals one-third(1/3)of tank volume. <br /> TA When the high water alarm is activated. <br /> - <br /> Inspect condition of tank(s) At least once very 3 years. ❑NA <br /> Inspect dispersal cells(s) At least once very 3 years. ❑NA <br /> Clean effluent filter ❑NA <br /> Inspect pump,pump controls&alarm ®NA <br /> Flush laterals and pressure test ©NA <br /> Other: 0 NA <br /> Other 'NA <br /> MAINTENANCE INSTRUCTIONS <br /> Inspections of tanks and dispersal cells shall be made by an individual carrying one of the following licenses or certifications:Master Plumber.Master <br /> Plumber Restricted Sewer, POWTS Inspector. POWTS Maintainer.Septage Servicing Operator(pumper).Tank inspections must include a visual <br /> inspection of the tank(s)to identify any missing or broken hardware,identify any cracks or leaks,measure the volume of combined sludge and scum and <br /> a check for any back up or ponding of effluent on the ground surface.If the volume of sludge and scum Is less than one-third(1/3)of the liquid volume <br /> of the tank.the tank does not need to be pumped and identifying cracks in floor or walls of the tank may not be possible at that time.The dispersal cell(s) <br /> shall be visually inspected to check the effluent levels in the observation pipes and to check for any ponding of effluent on the ground surface.The <br /> ponding of effluent on the ground surface may indicate a failing condition and requires the immediate notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum in any treatment tank equals one-third(1/3)or more of the tank volume,the entire contents of the <br /> tank shall be removed by a Septage Servicing Operator and disposed of in accordance with chapter NR 113.Wisconsin Administrative Code. <br /> s,7ti0-POwr§1.iG mew dcc <br />
The URL can be used to link to this page
Your browser does not support the video tag.