|
Help
|
About
|
Sign Out
Home
Browse
Search
DCPZP-2015-00952
DaneCounty-Planning
>
Zoning
>
1 Permits
>
2010s
>
2015
>
DCPZP-2015-00952
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/14/2015 10:23:51 AM
Creation date
12/10/2015 10:55:16 AM
Metadata
Fields
Template:
Zoning Permits
AccelaLink
DCPZP-2015-00952
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
72
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
POWTS OWNER'S MANUAL & MANAGEMENT PLAN Page 113 of I S <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> Owner <br /> Permit ft��� .. ..on <br /> _ - Tank Manufacturer Wieser I y �cc t� -c' E) NA <br /> IQ Septic ❑ Dose ❑ Holding Volume 1Qbo <br /> (gall <br /> DESIGN PARAMETERS Tank Manufacturer:W i A/Z-oc <br /> �St r ❑NA <br /> Number of Bedrooms, 0 NA ❑Septic Dose ❑ Holding Volume l b p a <br /> Number of Public Facility Units' 0 NA Vertical Distance Tank Bottom(s)to Service Pad I?- rp <br /> Estimated (average)Flow 7,�4 le (gal/day) Horizontal Distance Tank(s)to Service Pad ( <br /> '�� fill <br /> Design(peak)Flow=(estimated x 1.5): (gal/day) Specific servicing mechanics must be provided if vertical is>15 feel or <br /> 3(aGq y) it horizontal is>160 feel. Specific Instructions to be provided on back. <br /> In Situ Soil Application Rate ©,40 (gal/day/It') Effluent Filter Manufacturer._ e4c r'i-2 <br /> Standard(Domestic)Influent/Effluent Monthly average Effluent Filler Model LT I I$ ❑NA <br /> Fats,Oil&Grease (FOG) 530 mg/L x CZ> <br /> Biochemical Oxygen Demand (RODS) 5220 mg/L Pump Manufacturer Gov`d s <br /> Total Suspended Solids(TSS) 5150 mg/L NA Pump Model -z_../•‘ ❑NA <br /> High Strength Influent/Effluent )EGA 3\ � <br /> Monthly average Pretreatment Unit �"\.`e Kn;p 4' <br /> (FOG) >30 mg/L Manufacturer J <br /> (BODs) >220 mg/L ❑NA W K 20 0 W K"`7�, <br /> (TSS) >150 mg/L 8 Mechanical Aerallon ❑Peal Filler ❑ NA <br /> Pretreated Effluent Monthly average Disinfection ❑wetland <br /> CI Sand/Gravel Filter ❑Other <br /> (BODs) 530 mg/t. <br /> (TSS) 530 mg/L ❑NA Soil Absorption System <br /> Fecal Coliform(geometric mean) ,101 ❑In-Ground(gravity)Y) [��7 Moun In-Ground(pressure) [)NA <br /> Maximum Effluent Particle Size ye in dia. ❑NA ❑DriGrane ®Mound <br /> Other CI Drip-Line ❑Other. <br /> Wiesner 7_000 cpl grease -tterertwptor ❑ NA Other <br /> . . ❑NA <br /> MAINTENANCE SCHEDULE <br /> Service Event Service Frequency <br /> Pump out contents of tank(s) IS When combined sludge and scum equals one-third OA)of tank volume <br /> iiifWhen the high water alarm is activated <br /> Inspect condition of tank(s) At least once every ❑monlh(s) <br /> �l year(s) (Maximum 3 years) ❑ NA <br /> Inspect dispersal cell(s) At least once every: ❑month(s) <br /> 3 -@ years) (Maximum 3 years) ❑NA <br /> Clean effluent filler Al least once every ❑month(s) <br /> 3 ®year(s) ❑NA <br /> Inspect pump,pump controls 8 alarm Al least once every O month(s) — --- <br /> 3 ®year(s) ❑NA <br /> Flush laterals and pressure test At least once every o month(s) <br /> Other. W K�. np – year(s) ❑NA <br /> Sr15�,4 VAVv it \S"DV At- pvIri� At least once every: (p month(s) ❑ NA <br /> Other <br /> Rzelo,ce. Ic5••5bo r/3GC.O{.At.1r_At Il get GAccL ,.very I tzc..ir ❑NA <br /> MAINTENANCE INSTRUCTIONS <br /> Inspections of tanks and soil absorption systems shall be made by an individual carrying one of the following licenses or certifications: <br /> Master Plumber, Master Plumber Restricted Sewer, POWTS Inspector, POWTS Maintainer or Septage Servicing Operator (pumper). <br /> Tank Inspections must include a visual inspection of the tank(s)to identify any missing or broken hardware.Identify any cracks or leaks, <br /> measure the volume of combined sludge and scum and a check for any back up or ponding of effluent on the ground surface. The soil <br /> absorption system shall be visually inspected to check the effluent levels in the observation pipes and to check for any ponding of effluent <br /> on the ground surface. The ponding of effluent on the ground surface may indicate a failing condition and requires the Immediate <br /> notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum in any treatment tank equals one-third(SS) or more of the tank volume, the entire <br /> contents of the tank shall be removed by a Septage Servicing Operator (pumper) and disposed of in accordance with chapter NR 113. <br /> Wisconsin Administrative Code. <br /> All other services, including but not limited to the servicing of effluent filters,mechanical or pressurized components, pretreatment units. <br /> and any servicing at intervals of<_12 months,shall be performed by a certified POWTS Maintainer. <br /> A service report shall be provided to the local regulatory authority within 30 days of completion of any service event <br /> GMW-005(02/05) <br />
The URL can be used to link to this page
Your browser does not support the video tag.