Laserfiche WebLink
Sao° <br /> • eg `Public Heath Page of <br /> MADISON t=DANE COUNTY <br /> $eolthypeopleona rinwnr POINTS OWNER'S MANUAL & MANAGEMENT PLAN <br /> FILE INFORMATION SYSTEM SPECIFICATIONS- <br /> Owner: I Tank Manufacturer. ❑NA <br /> t��r�u E <br /> pA(,t(, 311 �)E E,t,�Pn�>£�t� Septic 0 Dose 0 Holding Volume 1� e _gal <br /> Permit POWTS Tank Manufacturer: t /4—C) 0 NA <br /> 0 Septic 0 Dose 9 Holding Volume C1 S0 gal <br /> DESIGN PARAMETERS Vertical Distance Tank Bottom(s)to Service Pad: ': 1 C it <br /> Number of Bedrooms: L 0 NA Horizontal Distance Tank(s)to Service Pad: L I ri 0 ft <br /> Number of Public Facility Units: 0 NA Specific servicing mechanics must be provide if vertical is>15 feet.or if <br /> Estimated(average)Flow: 400 gel/day hotzontal Is>150 feet.Specific instructions on plan addendum.. <br /> Design(peak)Flow=estimated x 1.5 (,Q nil gamey <br /> in Situ Soil Application Rate: gaUday/ftz Effluent Filter Manufacturer -CC) 0 NA <br /> Standard Domestic influentlEffluent Monthly average Effluent Filter Model: Fre <br /> Fats,Oil&Grease(FOG) X30 mgiL Pump Manufacturer: (A''�(uLUS 0 NA <br /> Biochemical Oxygen Demand(BOW 6220 mg/L 0 NA Pump Model: Mt o4 ii.A C <br /> Total Suspended Solids(rSS) •1150 mgiL Pretreatment Unit <br /> High Strength Influent/Effluent Monthly average Manufacturer: <br /> Fats,Oil&Grease(FOG) >30 mgiL 0 Mechanical Aeration 0 Peat Filter <br /> Biochemical Oxygen Demand(BOD§) >220 mgiL giir NA - 0 Disinfection ❑Wetland [1 NA 1 <br /> Total Suspended Solids(TSS) >150 moil_ i0 Sand/Gravel Filter 0 Other: <br /> Pretreated Effluent Monthly average Soil Absorption System <br /> Biochemical Oxygen Demand(BOD5) _s30 malt 0 In-Ground(gravity) 0 In-Ground(pressure) 0 NA <br /> Total Suspended Solids(TSS) s30 mgiL IA NA 0 At-Grade 0 Mound <br /> Fecal Coliform(geometric mean) •_10`ciu!i00m1 0 Drip-Line 0 Other: i <br /> Maximum Effluent Particle Size: 118 is dia. 0 ALA, t <br /> Other. Si NA Other: 0 NA! <br /> I <br /> MAINTENANCE SCHEDULE - <br /> Service Event 1 Service Frequency <br /> Pump out contents of tank(s) I 0 When combined sludge and scum equals one-third(1/3)of tank volume. <br /> p i 0 When the high water alarm is activated. <br /> inspect condition of tank(s) At least once very 3 years. ❑NA <br /> inspect dispersal cells(s) At least once very 3 years_ - 0 NA <br /> Clean effluent filter 0 NA <br /> Inspect pump,pump controls&alarm / 0 NA <br /> Flush laterals and pressure test / 0 NA I <br /> Other: 0 NA <br /> Other: 0 NA <br /> MAINTENANCE INSTRUCTIONS <br /> Inspections of tanks and dispersal calls shall be made by an Individ$ral carrying one of the following licenses or certifications:Master Plumber,Master <br /> Plumber Restricted Sewer, POINTS Inspector, POINTS Maintainer, Septage Servicing Operator (pumper).Tank inspections must include a visual <br /> Inspection of the tanks)to Identify any missing or broken hardware,identify any cracks or leaks,measure the volume of combined sludge and scum and <br /> a check for any back up or ponding of effluent on the ground surfaces If the volume of sludge and scum is less than one third(113)of the liquid volume <br /> of the tank,the tank does not need to be pumped and identifying credits in floor or walls of the lank may not be possible at that time.The dispersal cells) <br /> shall be visually inspected to check the effluent levels in the observiation pipes and to check for any ponding of effluent on the ground surface.The <br /> ponding of effluent on the ground surface may indicate a-taainc condition and requires the immediate notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum in any treatment tank equals one-third(1/3)or more of the tank volume,the entire contents of the <br /> tank shall be removed by a Septage Servicing Operator and disposed of in accordance with chapter NR 113,Wisconsin Administrative Coda. <br /> aW 2OiO-POwremeTprao.do <br />