|
Help
|
About
|
Sign Out
Home
Browse
Search
DCPZP-2015-00983
DaneCounty-Planning
>
Zoning
>
1 Permits
>
2010s
>
2015
>
DCPZP-2015-00983
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/12/2016 12:31:22 PM
Creation date
1/8/2016 12:59:25 PM
Metadata
Fields
Template:
Zoning Permits
AccelaLink
DCPZP-2015-00983
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
"`:'Public Health Page 7 of <br /> MADISON&DAME COUNTY <br /> taltFy people and placer .POWTS OWNER'S MANUAL & MANAGEMENT PLAN <br /> • <br /> FiLE INFORMATION SYSTEM SPECIFICATIONS <br /> Owner: ,-----p Tank Manufacturer: /7/ecL e. ❑NA <br /> Crit:4 b 1 . d V t.,51-0j t."2-1- W _ ' Septic.❑.Dose.. ❑Holding Volume. 1(45743 gal <br /> . Permit: POWTS# Tank Manufacturer: /Y)p,5 ti ❑NA <br /> ❑Septia Dose ❑Holding Volume !•D DO gal <br /> ;4 <br /> =DESIGN PARAMETERS Vertical Distance Tank Bottom(s)to Service Pad: 0 ft <br /> Number of Bedrooms: -5 ❑NA Horizontal Distance Tank(s)to Service Pad: . 5-1) ft <br /> Number.of Public Facillty.Units 0 NA Specific servicing mechanics must be provide if vertical Is>15 feet or if <br /> Estimated(average)Flow: , -0 gal/day horizontal Is>150 feet.Specific instructions on plan addendum. • <br /> Design(peak)Flow,=estimated x 1.5: •'J er> . gal/day _ <br /> In Situ Soil Application Rate: d-t), gal/day/ft2 Effluent Filter Manufacturer 0 r 4 4/CE, ❑NA <br /> Standard Domestic Influent/Effluent Monthly average Effluent Filter Model: /PO Ste .- / +{ T3-` IS O <br /> Fats;.Olt&Grease(FOG)-530 mg/L, . , • . Pump Manufacturers• . en..-.. ❑NA <br /> Biochemical Oxygen Demand(BOOS) 5220 mg/L ❑NA Pump Model: 1 h/a , - . <br /> Total Suspended Solids(TSS) 5150 mg/L Pretreatment Unit <br /> High Strength.Influent/Effluent . Monthly average Manufacturer: <br /> Fats,Oil&Grease(FOG) >30 mg/L ❑Mechanical Aeration ❑Peat Filter <br /> Biochemical Oxygen Demand(BOO,) >220 mg/L gilqA • ❑Disinfection ❑Wetland ❑NA <br /> Total Suspended Solids(TSS) >150 fng/L • - ❑Sand/Gravel Filter ❑Other: <br /> Pretreated Effluent Monthly average -- bsorption System <br /> • <br /> Biochemical Oxygen Demand(BOO,) 530 mg/L ❑In-Ground(gravity) _J ❑ In-Ground(pressure) ❑NA <br /> Total Suspended Solids(TSS) 530.mg/L CIA ❑At-Grade +�-Mound <br /> Fecal Coliform(geometric mean) 5104 cfu/100m1 ❑Drip-Line ,Lu.,Other: <br /> Maximum Effluent Particle Size: • . .1/8 in dia. ❑NA •_ . . • _ • .• <br /> Other: ❑NA Other: • ❑NA <br /> MAINTENANCE SCHEDULE '. " • • <br /> • .. - Service Event - • _ _ • . - Service Frequency • . .. . . : , . <br /> Pump-out contents of tanks) When combined sludge and scum equals one-third(1/3)of tank volume. - . <br /> ❑When the high water alarm is activated. . <br /> Inspect condition of tank(s) At least once very 3 years. ❑NA <br /> Inspect d(spersal cells(s) At least once very 3 years: • DNA <br /> Clean-effluent filter 151,5 • j14 J ❑NA <br /> Inspect pump,pump controls &alarm +4 ❑NA <br /> Flush laterals and pressure test // (' e C 7 • ❑NA <br /> Other: - ❑NA <br /> Other: • ❑NA <br /> MAINTENANCE INSTRUCTIONS <br /> • <br /> Inspections of tanks and dispersal cells shall be made by an Individual carrying one of the following licenses or certifications:Master Plumber,Master <br /> Plumber Restricted Sewer, POWTS Inspector, POWTS Maintainer, Septage Servicing Operator (pumper). Tank Inspections must Include a visual <br /> Inspection of the tank(s)to Identify any missing or broken hardware,identify any cracks or leaks;measure the volume of combined sludge and scum and <br /> a check for any back up or ponding of effluent on the ground surface.If the volume of sludge and scum Is less than one—third(1/3)of the liquid volume <br /> of the tank,the tank does not need to be pumped and Identifying cracks in floor or walls of the tank may not be possible at that time.The dispersal call(s) <br /> shall be visually Inspected to check the effluent levels In the observation pipes and to check for any pending of effluent on the ground surface.The <br /> pending of effluent on the ground surface may Indicate a falling condition and requires the Immediate notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum in any treatment tank equals one-third(1/3)or more of the tank volume,the entire contents of the <br /> tank shall be removed by a Septage Servicing Operator and disposed of In accordance with chapter NR 113,Wisconsin Administrative Code, <br /> 3,61201 0•P OW T SM GTplan.d oc <br />
The URL can be used to link to this page
Your browser does not support the video tag.