Laserfiche WebLink
a Public ealt Page o�— <br /> MADISON a DANE COUN t s <br /> Healti9i20131e041arae POINTS OWNER'S MANUAL &MANAGEMENT PLAN <br /> FiLE INFORMATION <br /> SYSTEM SPECIFICATIONS . <br /> ` = <br /> Ow r: - 1 Tank Manufacturer: �� 0 NA <br /> , s ./► L -61W' hi . G plc 0 Dose ❑Holding Volume ( 1p <br /> Permit POINTS"; Tank Manufacturer: �A. ArOI� <br /> 11 0 Septic .1 Dose 0 Hoidng Volume _k 0 gal <br /> DESIGN PARAMETERS Vertical Distance Tank Bottom(s)to Service Pad: 4 16 t <br /> Number of Bedrooms: 41 D NAB Distance Horizontal Distan Tank(s)to Service Pad: LI S ft <br /> Number of Public Facility Units: Q NA Specific servicing mechanics must be provide if vertical is>15 feet or if <br /> Estimated(average)Flour_ b0 galfday horizontal is>15D feet Specific instructions on pisn addendum_ <br /> Design(peak)Flow=estimated x 1.5: F 400 garloW i <br /> in Situ Soil Application Rate: galkleyffe 1 Effluent Filter Menufachwer Ole et4C0 0 NA <br /> Standard Domestic trtftuetitlEffluent: Monthly average ' Effluent Filter Model: rig <br /> Fats,Oil&Grease(FOG) 530 mgIL Pump Manufacturer_ LLB$ ❑ ` <br /> Biochemical Oxygen Demand(BOD,) <19n molt- 0 NA Pump Model: 5470 411 A-C. <br /> Total Suspended Solids(TSS) 4150 molt. Pretreatment Unit <br /> High Strength Inruuent/Effluent Monthly average Manufacture: i <br /> Fats,Oil&Grease(FOG) >30 mglL Cl Mechanical Aeration 0 Peat Filter <br /> Biochemical Oxygen Demand(BODD) >220 mgt ®NA • 0 Disinfection Cl Wetland Ei NA) <br /> Total Suspended Solids(TSS) >150 malL ❑Sand/Gravel Alter Q Other. <br /> Pretreated Effluent Monthly average Sal Absorption System <br /> Biochemical O>4ygen Demand(BOD%) 530 rnglL 0 In-Ground(gravity) Q In-Ground(pressure) .r NA <br /> Total Suspended Solids(TSS) s30 mg1L 0 NA 0 At-Grade El Mound <br /> Fecal Coliform(geometric mean) 410`curl i0t)rll 0 Drip-Line ❑03her. <br /> Mlaxfmcrar Eiilrneat Panicle Size: 09 In cis .l NA <br /> (I NA Other: CI NA{i <br /> Other. C --- --- <br /> MAINTENANCE SCHEDULE <br /> Service Event I Service Frequency <br /> 1 g When combined sludge and scum equals one-third(113)oftenkvolume. <br /> Pump out contents of tank(s) I NIA/hen the high water aiarm is activated. <br /> lNA <br /> Inspect condition of tank(s) 1 At least once very 3 years. • <br /> NAI <br /> inspect dispersal cells(s) At least:oncavery 3 Years_ 0 NA <br /> Clean affluent titter 1 V I2L`f <br /> A-LA12,1tAE-D 0 NA <br /> inspect pump,pump controls&alarm 1 �,�-1-x,1,,1 Palm� / 0 NA <br /> Flush laterals and pressure test n <br /> 0 t'lA <br /> � <br /> Other. <br /> 0 NA <br /> Other <br /> MAINTENANCE INSTRUCTIONS <br /> Inspections of tanks and dispersal calls shall be made by an individual carrying one of the following licenses or certification&Master Plumber,Master <br /> Plumber Restricted Sewer; POWTS Inspector,POWTS Maintainer;Ssptage Servicing Operator(pumper)-Tank inspections must include a visual <br /> inspection of the tank(s)to Identify any missing or broken hardware,idenrw any clacks or look%mute the volume of combined sludge and scum and <br /> a check for any back up or ponding of effluent on the ground surface.If the volume of sludge and scum is less than one-411n1(113)of The liquid avolume <br /> of the tank the tank does not need to be pumped and idenMying cracks In toot or walls of the tank may notbe possible aitrat tme.The dispersal cell(s) <br /> shall be visually inspected to check the affluent leveiss in The observation pipes and to check for any ponding of effluent on the ground surface_The <br /> pending of effluent on the ground surface may indicate a falling condIon and requires the immediate notification of the local regulatory authority- <br /> When the combined accurnuiaflon ofsiudtae and scum in any treatment tank equals one-third(113)or more ofthe lank volume,the entire contents of the <br /> tank shall be removed bye Septage Servicing Operator and disposed din accordance vdth chapierNR 113,Wisconsin Administrative Code_ <br /> ai1117A10-POWTSMeTplan.cc <br /> i <br /> i <br />