Laserfiche WebLink
. I, PUlbli& Health Page Z of�—DANE COUNTY <br /> !baldly people and places POWTS OWNER'S MANUAL& MANAGEMENT PLAN <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> Owner. '� Tank Manufacturer: /.0 ❑NA <br /> "' � I) _ . et optic.0 Dose_. ❑Ho�ngg Vol m. /' OD gal <br /> .. Permit: POWTS# Tank Manufacturer: ❑NA <br /> ❑Septic•Q Dose. ❑Holding Volume - • gal <br /> DESIGN PARAMETERS Vertical Distance Tank Bottom(s)to Service Pad: /V ft <br /> •- Number of Bedrooms: _ ❑NA Horizontal Distance Tank(s)to Service Pad: . 86 ft <br /> Number.of Public Fac.illty.Unitif. ❑NA Spe iffo servicing mechanics must be provide If vertical Is>15 feet or If <br /> Estimated(average)Flow 3 9(� gal/day horizaital Is>150 feet specific Instructions on plan addendum. • <br /> Design(peak)Flow.=estimated x 1.5: i5 gal/day : .. <br /> In Situ Soil Application Rate: L1 t<- gal/day/f2 Effluent Filter Manufacturer Or t iu<a ❑NA <br /> Standard Domestic Influent/Effluent Monthly average Effluent Filter Model: -Ir" a''i y- (+(8^ I s a <br /> Fats;-011&Gr9.ase(FOG).s3Q mglt.. . . - . : Pump Manufacturer. . ❑NA <br /> Biochemical Oxygen Demand(BON 6220 mg/L ❑NA Pump Model: _ . <br /> Total Suspended Solids(TSS) 5150 mg/L Pretreatment Unit <br /> High Strength.Influent/Effluent . Monthly average Manufacturer. ' <br /> Fats,Oil 5 Grease(FOG) >30 mg/L ❑Mechanical Aeration ❑Peat Filter • <br /> Biochemical Oxygen Demand(BON >220 mg/L DOOM A ❑Disinfection ❑Wetland Total Suspended Solids(TSS) >150ing/L - ❑Sand/Gravel Met ❑Other.•• 011A TT� <br /> Pretreated Effluent Monthly average Soil Absorption System - <br /> Biochemical Oxygen Demand(BOO,) 530 mg/I n-Ground <br /> �' (gravity)ty) ❑In-Ground(pressure) ❑NA <br /> Total Suspended Solids(TSS) 530 mg/L [DNA ❑At-Grade ❑Mound <br /> Fecal Coliform(geometric mean) 5104 cN/IOOmI ❑Drip-Lane ❑Other. <br /> Maximum Effluent Particle Size: . .1/8 India. ❑NA .. . . <br /> Other. . - . . • ❑NA Other: • -. ❑NA <br /> • <br /> MAINTENANCE SCHEDULE ` . • • <br /> .. • Service Event - • : • • .. . Service Frequency . . . . . <br /> Pump out contents of tank(s) en combined sludge and scum equals one-third(1/3)of tank volume. . <br /> When the high water alarm is activated.: .. <br /> Inspect,condigott of tank(s) , At least once very 3 years. ❑NA <br /> • <br /> Inspect dispersal cells(s) _ ' At least once very 3 years:, - - _ U NA <br /> Clean effluent filter ( l�(p t ` r‹e' //e4 0- 0 NA Inspect pump,pump controls&alarm - ❑NA <br /> Flush laterals and pressure test • ❑NA <br /> Other: ❑NA <br /> Other: • - ❑NA <br /> MAINTENANCE INSTRUCTIONS • • - • <br /> Inspections of tanks and dispersal cells shall be made by an individual carrying one of the following licenses or certlicaflons:Master Plumber,Master <br /> Plumber Restricted Sewer,POWTS Inspector, POWTS Maintainer, Septage Servicing Operator(pumper). Tank inspections must Include a visual <br /> Inspection of the tanks)to Identify any missing or broken hardware,Identify any cracks or leaks;measure the volume of combined sludge and scum and <br /> a check for any back up or pondlng of effluent on the ground surface.If the volume of sludge and scum Is lees than one—third(1/3)of the liquid volume <br /> of the tank,the tank does not need to be pumped and Identifying cracks In floor or walls of the tank may not be possible at that time.The dispersal cel(s) <br /> shall be visually Inspected to-died(the effluent levels In the observation pipes and to check for any ponding of effluent on the ground surface.The <br /> pondlng of effluent on the ground surface may Indicate a falling condition and requIres the Immediate notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum In any treatment tank equals one-third(1/3)or more of the tank volume,the entire contents of the <br /> tank shall be removed by a Septage Servicing Operator and disposed of In accordance with chapter NR 113,Wisconsin Administrative Code. <br /> 3r8/2o1o•POWTSMOTplan.doc . <br />