|
Help
|
About
|
Sign Out
Home
Browse
Search
DCPZP-2016-00333
DaneCounty-Planning
>
Zoning
>
1 Permits
>
2010s
>
2016
>
DCPZP-2016-00333
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/14/2016 1:06:55 PM
Creation date
6/14/2016 1:06:51 PM
Metadata
Fields
Template:
Zoning Permits
AccelaLink
DCPZP-2016-00333
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Public Health g � <br /> ;:•. Pa e� of <br /> • <br /> - Heohhy people and pines POWTS OWNER'S MANUAL & MANAGEMENT PLAN <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> Owner: Tank Manufacturer: F- <br /> 4-A4-n Septic Li Dose ❑ Holding Volume J.2 gal <br /> Permit: POWTS# Tank Manufacturer: - ❑ A <br /> N <br /> ❑ Septic [2 Dose ❑ Holding Volume 7 a gal <br /> DESIGN PARAMETERS Vertical Distance Tank Bottom(s)to Service Pad: f aZ ft <br /> Number of Bedrooms: ❑ NA Horizontal Distance Tank(s) to Service Pad: 7 ft <br /> Number of Public Facility Units: 1j NA Specific servicing mechanics must be provide if vertical is >15 feet or if <br /> Estimated(average)Flow: � gal/day horizontal is>150 feet.Specific instructions on plan addendum. <br /> Design(peak)Flow=estimated x 1.5: 6.-4:7 t? gal/day <br /> In Situ Soil Application Rate: c . gal/day/ft2 Effluent Filter Manufacturer Sj ;ZC/7 ❑ NA <br /> Standard Domestic Influent/Effluent Monthly average Effluent Filter Model: S` j— — <br /> Fats,Oil&Grease(FOG) 5530 mg/L Pump Manufacturer: � y ❑ NA <br /> Biochemical Oxygen Demand(BOD5) 5220 mg/L ❑ NA Pump Model: 9 3 <br /> Total Suspended Solids(TSS) 5150 mg/L Pretreatment Unit <br /> High Strength Influent/Effluent Monthly average Manufacturer: <br /> Fats,Oil&Grease(FOG) >30 mg/L ❑Mechanical Aeration ❑ Peat Filter <br /> Biochemical Oxygen Demand(BOD5) >220 mg/L 1 r NA ❑Disinfection ❑Wetland [' NA <br /> Total Suspended Solids(TSS) >150 mg/L ❑Sand/Gravel Filter ❑Other: <br /> Pretreated Effluent Monthly average Soil Absorption System <br /> Biochemical Oxygen Demand(BOD5) 530 mg/L IJ In-Ground(gravity) ❑ In-Ground(pressure) ❑ NA <br /> Total Suspended Solids(TSS) 530 mg/L TVA ['At-Grade ❑Mound <br /> Fecal Coliform(geometric mean) 5104 cfu/100mI ❑Drip-Line ❑Other: <br /> Maximum Effluent Particle Size: 1/8 in dia. ❑ NA <br /> Other. OrNA Other: (i NA <br /> MAINTENANCE SCHEDULE <br /> Service Event Service Frequency <br /> Pump out contents of tank(s) When combined sludge and scum equals one-third(1/3)of tank volume. <br /> When the high water alarm is activated. <br /> Inspect condition of tank(s) At least once very 3 years. ❑ NA <br /> Inspect dispersal cells(s) At least once very 3 years. ❑ NA <br /> Clean effluent filter ❑ NA <br /> Inspect pump, pump controls&alarm ❑ NA <br /> • <br /> Flush laterals and pressure test ®'NA <br /> Other ra NA <br /> Other: l'NA <br /> MAINTENANCE INSTRUCTIONS <br /> Inspections of tanks and dispersal cells shall be made by an individual carrying one of the following licenses or certifications: Master Plumber, Master <br /> Plumber Restricted Sewer, POWTS Inspector, POWTS Maintainer, Septage Servicing Operator (pumper). Tank inspections must include a visual <br /> inspection of the tank(s)to identify any missing or broken hardware,identify any cracks or leaks,measure the volume of combined sludge and scum and <br /> a check for any back up or ponding of effluent on the ground surface. If the volume of sludge and scum is less than one-third(1/3)of the liquid volume <br /> of the tank,the tank does not need to be pumped and identifying cracks in floor or walls of the tank may not be possible at that time.The dispersal cell(s) <br /> shall be visually inspected to check the effluent levels in the observation pipes and to check for any ponding of effluent on the ground surface. The <br /> ponding of effluent on the ground surface may indicate a failing condition and requires the immediate notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum in any treatment tank equals one-third(1/3)or more of the tank volume,the entire contents of the <br /> tank shall be removed by a Septage Servicing Operator and disposed of in accordance with chapter NR 113,Wisconsin Administrative Code. <br /> l;8,2010-rowTsI.IG rrl2n.doc '�� ( (p(t <br />
The URL can be used to link to this page
Your browser does not support the video tag.