Laserfiche WebLink
Public Health I • Page%Cot V <br /> Hcoltyvpevplr nod plarrs POWTS OWNER'S MANUAL& MANAGEMENT PLAN <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> Owner Tank Manufacturer. ` `S� ❑NA <br /> C,A/E/C,"L- /< Septic ❑Dose ❑Holding Volume /- `/ gal <br /> Permit' POWTS# Tank Manufacturer: WNA <br /> ❑Septic 412.. e ❑Holding Volume gal <br /> DESIGN PARAMETERS Vertical Distance Tank Bottom(s)to Service Pad: /3 ft <br /> Number of Bedrooms ❑NA Horizontal Distance Tank(s)to Service Pad: s=' ft <br /> Number of Public Facility Units: / ID NA Specific servicing mechanics must be provide if vertical is>15 feet or if <br /> Estimated(average)Flow: 7 gal/day horizontal is>150 feet.Specific instructions on plan addendum. <br /> Design(peak)Flow=estimated x 1.5. 6-° gal/day <br /> In Situ Soil Application Rate cu'$/ gal/day/II' Effluent Filter Manufacturer- ❑NA <br /> Standard Domestic Influent/Effluent Monthly average Effluent Filter Model: Et / C? <br /> Fats.Oil&Grease(FOG) 530 mg/L Pump Manufacturer: ®NA <br /> Biochemical Oxygen Demand(BODS) 5220 mg/L ❑NA Pump Model: <br /> Total Suspended Solids(TSS) 5150 mg/L Pretreatment Unit <br /> High Strength Influent/Effluent Monthly average Manufacturer: <br /> Fats.Oil&Grease(FOG) >30 mg/L ❑Mechanical Aeration ❑Peat Filter <br /> Biochemical Oxygen Demand(BOD5) >220 mg/L tf NA ❑Disinfection ❑Welland p NA <br /> Total Suspended Solids(TSS) >150 mg/L ❑Sand/Gravel Filter ❑Other: <br /> — <br /> Pretreated Effluent Monthly average Soil Absorption System <br /> Biochemical Oxygen Demand(BODs) 530 mg/L 'In-Ground(gravity) ❑In-Ground(pressure) ❑NA <br /> Total Suspended Solids(TSS) 530 mg/L 12'NA ❑At-Grade ❑Mound <br /> Fecal Coliform(geometric mean) 510'cfu/100m1 ❑Drip-Line ❑Other: <br /> Maximum Effluent Particle Size: 1/8 in dia. ❑NA <br /> Other: NNA Other: EZ1 NA <br /> MAINTENANCE SCHEDULE <br /> Service Event Service Frequency <br /> Pump out contents of tank(s) When combined sludge and scum equals one-third(1/3)of tank volume. <br /> ['When the high water alarm is activated. <br /> Inspect condition of tank(s) At least once very 3 years. ❑NA <br /> Inspect dispersal cells(s) At least once very 3 years. ❑NA <br /> Clean effluent filter f ❑NA <br /> Inspect pump,pump controls&alarm ®NA <br /> Flush laterals and pressure test ®NA <br /> Other: Ig NA <br /> Other: NA <br /> MAINTENANCE INSTRUCTIONS <br /> Inspections of tanks and dispersal cells shall be made by an individual carrying one of the following licenses or certifications:Master Plumber,Master <br /> Plumber Restricted Sewer, POWTS Inspector. POWTS Maintainer. Septage Servicing Operator(pumper). Tank inspections must include a visual <br /> inspection of the tank(s)to identify any missing or broken hardware,identity any cracks or leaks,measure the volume of combined sludge and scum and <br /> a check for any back up or ponding of effluent on the ground surface.li the volume of sludge and scum is less than one-third(1/3)of the liquid volume <br /> of the tank,the tank does not need to be pumped and identifying cracks in floor or walls of the tank may not be possible at that time.The dispersal cell(s) <br /> shall be visually inspected to check the effluent levels in the observation pipes and to check for any ponding of effluent on the ground surface.The <br /> ponding of effluent on tire ground surface may indicate a failing condition and requires the immediate notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum in any treatment tank equals one-third(1/3)or more of the tank volume,the entire contents of the <br /> lank shall be removed by a Septage Servicing Operator and disposed of in accordance with chapter NR 113,Wisconsin Administrative Code. <br /> ■:8:7niPPOwrcr+Grnia dos <br />