Laserfiche WebLink
10.16(4)(b)—(6)(a)2. <br /> pump islands and related canopies, including or public improvements. The zoning <br /> canopy supports, may be located within the administrator may require written verification <br /> setback area, but not closer than 20 feet to the from appropriate agencies before issuing a <br /> boundary line, provided that in any such district zoning permit. / <br /> in an urban area, pumps, pump islands, and 6. No part of the structure shall extend into t� <br /> related canopies, including canopy supports, any required vision clearance trian.le. <br /> may be located within the setback area but the For sing e ami y residences or duplex <br /> pumps, pump islands and canopy supports may residence buildings, single story bay windows <br /> not be located closer than 12 feet to the may be constructed in such a manner that they <br /> boundary line, and no part of the canopy may be project three (3) feet or less into the front yard <br /> located closer than 3 feet to the boundary line. provided that such windows do not occupy, in <br /> The total height of any overhead canopy shall the aggregate, more than one-third (1/3) of the <br /> not exceed 20 feet as measured to the highest front wall of the building. <br /> point of the structure and shall be located a (g) On lake front lots, accessory buildings may <br /> minimum of 8 feet above grade. As used in this be located in front yards subject to the locational <br /> paragraph (a), boundary line means the more requirements of s. 10.16(6)(a)1. provided, <br /> restrictive of either the lot line or the highway however,that the setback requirements are met. <br /> right-of-way line. (5) Side yards. (a) Lots of nonconforming <br /> (b) In case of interior lots having frontage on width. <br /> two (2) side streets, no accessory building shall 1. On lots 50 feet or more in width but less <br /> extend into the setback area of either street. that 60 feet, the minimum aggregate side yards <br /> (c) When the side line of an interior lot is shall be 15 feet and no single side yard shall be <br /> formed wholly or in part by the rear line of an less than five (5)feet. <br /> abutting corner lot and the street side yard for 2. On lots less than 50 feet in width the <br /> the main building is less than the setback from minimum side yard on each side shall be five (5) <br /> the main building facing such street, the setback feet. <br /> for the building on such interior lot may be (b) Corner lots. <br /> modified so as to be midway between the side 1. When the long side of a corner lot is <br /> yard for the building on the corner lot and the formed by a class A, B or C highway the side <br /> setback from such street. yard on that street shall conform to the setback <br /> (d) In platted subdivisions recorded before the requirements for such highway. <br /> adoption of this ordinance where a building line 2. When the long side of a corner lot is <br /> shall have been established by the construction formed by a class D or E highway, the setback <br /> of buildings on 30 percent of the lots in any one from the lot line of the long side shall not be less <br /> (1) block, such established setback line shall be than one-fifth (1/5) of the lot depth measured <br /> the setback for that block, but in no event shall from the long side except on lots of less than 60 <br /> such setback be less than 20 feet. feet, then the setback shall not be less than 12 <br /> (e) For purposes of entry to buildings, steps, feet. For buildings with attached garages facing <br /> stoops, decks or ramps may be constructed in the long side and having access to the long side <br /> such a manner that they intrude into the required of the lot, the minimum setback of the garage <br /> front yard setback area provided that all of the from the lot line shall be not less than 20 feet. <br /> following limitations and conditions are satisfied: (6) Rear yards. (a) Location of accessory <br /> ..„/ <br /> 1. Height shall not exceed 5 feet above buildings in rear yards. <br /> , ground level, not including railings. 1. On interior lots 60 feet or more in width no <br /> 15/✓ 2. Width shall not exceed 12 feet side to side. accessory building shall be erected, moved or <br /> 3. Structure shall extend no farther than 10 added to so as to be nearer than four (4) feet to <br /> 3-11 feet from the front of the building to which it is the side lot or rear lot line; provided, however, if <br /> attached or up to the front property line, the front building line of any accessory building is <br /> whichever is less. located closer than 10 feet from the rear building <br /> ` 4. Structure shall not be enclosed. Railings line of a residence, the same side and rear yards <br /> In� — which do not exceed 3 1/2 feet in height and as required for a principal or residential building <br /> which are of open architecture and not solid in shall be maintained. <br /> appearance are permitted. 2. On interior lots less than 60 feet in width <br /> 111--c 5. Structure shall not interfere with existing or no accessory building shall be erected, moved or <br /> vI planned roads, sidewalks, gas and electrical added to so as to be nearer than two and one- <br /> half sewers, drainageways, and other utilities half (2-1/2) feet to a side or rear lot line; <br /> rtl- <br /> ` 5 Page 10-49 <br /> <Q �9 rev. 013116 <br />