|
Help
|
About
|
Sign Out
Home
Browse
Search
DCPZP-2016-00483
DaneCounty-Planning
>
Zoning
>
1 Permits
>
2010s
>
2016
>
DCPZP-2016-00483
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2016 1:11:23 PM
Creation date
8/8/2016 3:08:48 PM
Metadata
Fields
Template:
Zoning Permits
AccelaLink
DCPZP-2016-00483
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
° �` Publ'c Health <br /> MADISON&DANE COUNTY Page of S <br /> Healthy people and places ..POWTS OWNER'S MANUAL & MANAGEMENT-PLAN <br /> • <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> Owner: Tank Manufacturer: Meade ❑NA <br /> 6ei^cL/(D d- Yu )655 in 9ror - ® Septic. 0.Dose__ ❑ Holding Volume. /Deb gal <br /> Permit: �l POWT$# Tank Manufacturer: ❑NA <br /> • ❑ Septic-❑ Dose. ❑ Holding Volume • • gal <br /> `,--DESIGN PARAMETERS Vertical Distance Tank Bottom(s)to Service Pad: /0 ft <br /> Number of Bedrooms: 3 ❑ NA Horizontal Distance Tank(s)to Service Pad: . /9---0 ft <br /> Number.of Public Facility.Units: ❑NA Specific servicing mechanics must be provide If vertical is >15 feet or If <br /> Estimated(average)Flow: 3 00 gaf/day horizontal Is>150 feet.Specific instructions on plan addendum. - <br /> Design(peak) Flow.=estimated x 1.5: - -15-0 gal/day . -. - <br /> In Situ Soil Application Rate: , Y PI/day/ft' Effluent Filter Manufacturer a f.'/ca ❑NA <br /> Standard Domestic Influent/Effluent Monthly average .Effluent Filter Model: ;7'O b'a).- 1 ( B- 1-So <br /> . Fats;-Oil&Grease(FOG):530 mg/L. . - Pump Manufacturer, _ NA <br /> Biochemical Oxygen Demand(BO05) 5220 mg/L ❑ NA Pump Model: _ - . <br /> Total Suspended Solids(TSS) 5150 mg/L Pretreatment Unit <br /> High Strength.Influent/Effluent . Monthly average Manufacturer: <br /> Fats,Oil&Grease(FOG) >30 mg/L ❑Mechanical Aeration ❑Peat Filter <br /> Biochemical Oxygen.Demand(BO05) >220 mg/L ® NA . ❑Disinfection • ❑Wetland El NA <br /> Total Suspended Solids(TSS) >150 Mg/ - ❑Sand/Gravel Filter ❑Other: <br /> Pretreated Effluent Monthly average Soil Ab sorption System . - -• <br /> Biochemical Oxygen Demand(BOD5) 530 mg/L El In-Ground(gravity) ❑In-Ground(pressure) ❑NA <br /> Total Suspended Solids(TSS) s307g/L g NA ❑At-Grade ❑Mound <br /> Fecal Coliform(geometric mean) 5104 cfu/100m1 ❑Drip-Line ❑Other: <br /> Maximum Effluent Particle Size: • • .3 In dia�. ❑ NA •. . , •• .• <br /> Other: - ❑ NA Other: " [3]NA <br /> MAINTENANCE SCHEDULE <br /> . Service.Event . .. - - - . . . -. Service Frequency . .. - . : . . <br /> Pump out contents of tank(s) 2 When combined sludge.and.scum equals one-third(1/3)of tank volume,- . <br /> ❑When the high water alarm Is.activated. <br /> Inspect condition of tanks) . At least once very 3 years. ❑NA <br /> Inspect dispersal.cells(s) _ At least once■very 3 years: - - •. - . DNA <br /> Clean-effluent filter /9 i- jee,s,{ .0;ice a t ear 0 N• <br /> Inspect pump, pump controls &alarm ❑NA• <br /> Flush laterals and pressure test ' ❑NA <br /> Other: ❑NA <br /> Other: - ❑NA <br /> MAINTENANCE INSTRUCTIONS - <br /> inspections of tanks and dispersal cells shall be made by an individual carrying one of the following licenses or certifications: Master Plumber, Master <br /> Plumber Restricted Sewer, POWTS inspector, POWTS Maintainer, Septage Servicing Operator (pumper). Tank Inspections must Include a visual <br /> Inspection of the tanks)to Identify any missing or broken hardware,Identify any cracks or leaks;measure the volume Of combined sludge and scum and <br /> a check for any back up or pending of effluent on the ground surface.If the volume of sludge and scum Is less than one—third(1/3)of the liquid volume <br /> of the tank,the tank does not need to be pumped and Identifying cracks In floor or walls of the tank may not be possible at that time.The dispersal cell(s) <br /> shall be visually Inspected to check the effluent levels In the observation pipes and to check for any ponding of effluent on the ground surface,The <br /> ponding of effluent on the ground surface may Indicate a failing condition and requires the Immediate notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum in any treatment tank equals one-third(1/3)or more of the tank volume,the entire contents of the <br /> tank shall be removed by a Septage Servicing Operator and disposed of in accordance with chapter NR 113,Wisconsin Administrative Code. <br />
The URL can be used to link to this page
Your browser does not support the video tag.