Laserfiche WebLink
Public Health <br /> PageS79 of 5 <br /> , Hcollty people rind placrs POWTS OWNER'S MANUAL&MANAGEMENT PLAN <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> Owner: Tank Manufacturer. G/- T-j ❑NA <br /> C.7,-I x.— T`�cs-s ig Septic ❑Dose ❑Holding Volume /--- 1''' gal <br /> Permit: POWTS fl Tank Manufacturer. Ci,- ❑NA <br /> ❑Septic ]Dose ❑Holding Volume 6-°-°6-°-° gal <br /> DESIGN PARAMETERS • Vertical Distance Tank Bottom(s)to Service Pad: Jy ft <br /> Number of Bedrooms: .3 ❑NA Horizontal Distance Tank(s)to Service Pad: / it <br /> Number of Public Facility Units: 2 NA Specific servicing mechanics must be provide if vertical is>15 feet or it <br /> Estimated(average)Flow: Sao gal/day horizontal is>150 feet.Specific instructions on plan addendum. <br /> Design(peak)Flow=estimated x 1.5: �Ss3 gal/day, <br /> In Situ Soil Application Rate: o. 7/". gal/day/f13 Effluent Filter Manufacturer SJ/7-I-7---C7-../ ❑NA <br /> Standard Domestic Influent/Effluent Monthly average Effluent Filter Model: /av <br /> Fats.On&Grease(FOG) 530 mg/L Pump Manufacturer. i'-'5.v4_0_1- ❑NA <br /> Biochemical Oxygen Demand(BOOS) 220 mg/L ❑NA Pump Model: �s�,5/t/:T,"1 2, /_ <br /> - <br /> Total Suspended Solids(TSS) 5150 mg/L Pretreatment Unit <br /> High Strength Influent/Effluent Monthly average Manufacturer: <br /> Fats,Oil&Grease(FOG) >30 mg/L ❑Mechanical Aeration ❑Peat Filter <br /> Biochemical Oxygen Demand(BODS) >220 mg/L t NA ❑Disinfection ❑Welland Fr NA <br /> Total Suspended Solids(TSS) >150 mg/L ❑Sand/Gravel Filter ❑Other. <br /> Pretreated Effluent Monthly average Soil Absorption System <br /> Biochemical Oxygen Demand(HODS) 530 mg/L -la•In-Ground(gravity) ❑In-Ground <br /> (pressure) ❑NA <br /> Total Suspended Solids(TSS) 530 mg/L 'RI NA ❑At-Grade ❑Mound <br /> Fecal Coliform(geometric mean) 510'cfu/100m1 ❑Drip-Line ❑Other. <br /> Maximum Effluent Particle Size: 1/8 in dia. ❑NA <br /> Other. ANA Other. <br /> leNA <br /> MAINTENANCE SCHEDULE <br /> Service Event Service Frequency <br /> IRI <br /> Pump out contents of tank(s) When combined sludge and scum equals one-third(1/3)of tank volume. <br /> 2 When the high water alarm is activated_ <br /> Inspect condition of tank(s) At least once very 3 years. ❑NA <br /> Inspect dispersal cells(s) At least once very 3 years. ❑NA <br /> Clean effluent filter ❑NA <br /> . <br /> Inspect pump,pump controls&alarm ❑NA <br /> Flush laterals and pressure test I/I NA <br /> Other. [c NA <br /> Other. 130■1A <br /> MAINTENANCE INSTRUCTIONS <br /> Inspections of tanks and dispersal cells shall be made by an individual carrying one of the following licenses or certifications:Master Plumber,Master <br /> Plumber Restricted Sewer, POWTS Inspector, POWTS Maintainer,Seplage Servicing Operator(pumper).Tank inspections must include a visual <br /> inspection of the lank(s)to identify any missing or broken hardware,identify any cracks or leaks,measure the volume of combined sludge and scum and <br /> a check for any back up or ponding of effluent on the ground surface.If the volume of sludge and scum is less than one-third(1/3)of the liquid volume <br /> of the tank,the tank does not need to be pumped and identifying cracks in floor or walls of the tank may not be possible at that time.The dispersal cell(s) <br /> shall be visually inspected to check the effluent levels in the observation pipes and to check for any ponding of effluent on the ground surface.The <br /> ponding of effluent on the ground surface may indicate a failing condition and requires the immediate notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum in any treatment tank equals one-third(1/3)or more of the tank volume,the entire contents of the <br /> tank shall be removed by a Septage Servicing Operator and disposed of in accordance with chapter NR 113,Wisconsin Administrative Code. <br /> trmre-POWTSI.IGTCrrn doc <br />