|
Help
|
About
|
Sign Out
Home
Browse
Search
DCPZP-2016-00539
DaneCounty-Planning
>
Zoning
>
1 Permits
>
2010s
>
2016
>
DCPZP-2016-00539
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/6/2016 1:44:50 PM
Creation date
9/2/2016 12:54:56 PM
Metadata
Fields
Template:
Zoning Permits
AccelaLink
DCPZP-2016-00539
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
58
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Public Health Pagelo of 7 <br /> Hrallhrpeop/eand places POWTS OWNER'S MANUAL&MANAGEMENT PLAN <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> Owner: Tank Manufacturer. �„S�f ❑NA <br /> //ATe: <i✓YG7C,Z 1Septic ❑Dose ❑Holding Volume /-2S12 gal <br /> Permit: POWTS# Tank Manufacturer: G,¢. .sT ❑NA <br /> ❑Septic 0 Dose ❑Holding Volume 7J gal <br /> DESIGN PARAMETERS Vertical Distance Tank Bottom(s)to Service Pad: 7 ft <br /> Number of Bedrooms: 5l ❑NA Horizontal Distance Tank(s)to Service Pad: - ' ft <br /> Number of Public Facility Units: ®NA Specific servicing mechanics must be provide if vertical Is>15 feet or if <br /> Estimated(average)Flow: V� <br /> gal/day horizontal is>150 feet.Specific instructions on plan addendum. <br /> Design(peak)Flow=estimated x 1.5: gaVday <br /> In Situ Soil Application Rate: o_ (■ gal/day/ft' Effluent Filter Manufacturer „Xi..77 c"%' ❑NA <br /> Standard Domestic Influent/Effluent Monthly average Effluent Fitter Model: <br /> Fats.Oil&Grease(FOG) 530 mg/L Pump Manufacturer. zv�C ❑NA <br /> Biochemical Oxygen Demand(BODS) 5220 mg/L ❑NA Pump Model: / 7 <br /> Total Suspended Solids(TSS) 5150 mg/L Pretreatment Unit <br /> High Strength Influent/Effluent Monthly average Manufacturer. <br /> Fats.Oil&Grease(FOG) >30 mg/L ❑Mechanical Aeration ❑Peat Filter <br /> Biochemical Oxygen Demand(BODS) >220 mg/L g NA ❑Disinfection ❑Wetland El NA <br /> Total Suspended Solids(TSS) >150 mg/L ❑Sand/Gravel Filter ❑Other <br /> Pretreated Effluent Monthly average Soil Absorption System <br /> Biochemical Oxygen Demand(BOOS) 530 mg/L ❑In-Ground(gravity) ❑In-Ground(pressure) ❑NA <br /> Total Suspended Solids(TSS) 530 mg/L ®NA ❑At-Grade 1$Mound <br /> Fecal Coliform(geometric mean) 510'cfu/100n1 ❑Drip-Line ❑Other: <br /> Maximum Effluent Particle Size: 1/8 in dia. ❑NA <br /> Other. ®NA Other. ®NA <br /> MAINTENANCE SCHEDULE <br /> Service Event Service Frequency <br /> Pump out contents of tank(s) ®When combined sludge and scum equals one-third(1/3)of tank volume. <br /> ®When the high water alarm is activated. <br /> Inspect condition of tank(s) At least once very 3 years. ❑NA <br /> Inspect dispersal cells(s) At least once very 3 years. ❑NA <br /> Clean effluent filter ❑NA <br /> Inspect pump,pump controls&alarm ❑NA <br /> Flush laterals and pressure test ❑NA <br /> Other. ®NA <br /> Other. 121 NA <br /> MAINTENANCE INSTRUCTIONS <br /> Inspections of tanks and dispersal cells shall be made by an Individual carrying one of the following licenses or certifications:Master Plumber,Master <br /> Plumber Restricted Sewer, POWTS Inspector,POWTS Maintainer.Septage Servicing Operator(pumper).Tank inspections must include a visual <br /> inspection of the tank(s)to identify any missing or broken hardware,identify any cracks or leaks,measure the volume of combined sludge and scum and <br /> a check for any back up or ponding of effluent on the ground surface.If the volume of sludge and scum is less than one—third(1/3)of the liquid volume <br /> of the tank,the tank does not need to be pumped and identifying aadks in floor or walls of the tank may not be possible at that time.The dispersal cells) <br /> shall be visually inspected to check the effluent levels in the observation pipes and to check for any ponding of effluent on the ground surface.The <br /> ponding of effluent on the ground surface may Indicate a failing condition and requires the immediate notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum in any treatment tank equals one-third(1/3)or more of the tank volume,the entire contents of the <br /> tank shall be removed by a Septage Servicing Operator and disposed of in accordance with chapter NR 113,Wisconsin Administrative Code. <br /> teen iO.POW rsuoreim.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.