Laserfiche WebLink
I <br /> I <br /> Page 7f 7 <br /> `Ail other services, including but not limited to the servicing of effluent filter, mechanical or pressurized components, pretreatment units, and any <br /> servicing at intervals of 512 months,shall be performed by a certified POINTS Maintainer. <br /> A service report shall be provided to the Environmental Health and Labs Division of Public Health Madison and Danz County within 30 days of <br /> completion of any service event. .- <br /> START UP AND OPERATION <br /> For new construction, prior to use of the POWTS,check treatment tank(s)for the presence of painting products,solvent or other chemicals or sediment <br /> that may Impede the treatment process and/or damage the soil absorption cell(s). If high amounts of these materials are detected In the tanks,have the <br /> contents of the tank(s)removed by a septage servicing operator prior to use. <br /> -- <br /> System start up shall not occur when soil conditions are frozen at the Infiltrative surface. - <br /> During extended power outages-pump tanks may fill above normal high-water levels.When power is restored the excess wastewater will be discharged <br /> to the dispersal cell(s)in one large dose and may overload them resulting In the backup or surface discharge ofeffiuent.To avoid this situation have the <br /> contests of the pump tank removed by a Septage Servicing Operator prior to restoring power to-the effluent pump or contact a Plumber or POWTS <br /> Maintainer to assist in manually operating the pump controls to restore normal levels-within the pump tank. . <br /> Do not drive or park vehicles over tanks and dispersal cells.. Do not drive or park over, or otherwise disturb or compact, the area within 15 feet down ' <br /> slope of any mound or at-grade soil absorption area. •- . - • <br /> Reduction or elimination of the following from the wastewaterstream May Improve the performance and prolong the life of the POWTS:antibiotics,"baby <br /> wipes,cigarette butts, condoms,cotton swabs, degreasers,dental floss,diapers, disinfectants,fat, foundation drain (sump pump)discharge,fruit and <br /> vegetable peelings, gasoline, greases, herbicides, meat scraps,medications,oils, painting products,pesticides, sanitary napkins, tampons,and water <br /> softener brine. - <br /> ABANDONMENT " <br /> When the POWTS fails andlor is permanently taken out of service the following steps shall be taken to Insure that the system is properly and safely <br /> abandoned in compliance with s_Comm 83.33,Wisconsin Administrative Code: <br /> ▪ All piping to tanks,pits and othersoll absorption systems--shall be disconnected and the abandoned pipe openings sealed. • <br /> • The contents of all tanks and pits Shall be removed and properly disposed of by a Saptage Serii'cing Operator(pumper). <br /> • After pumping,all tanks-and pits shall-be excavated and removed or their covers removed and the void space filled with soil, gravel or another inert <br /> solid material <br /> CONTINGENCY PLAN _ <br /> If the POWTS fails and cannot be repaired the following measures have been,or must be taken,to provide a code compliant replacement system: <br /> • ❑ A suitable replacement area has been evaluated and may be utilized for the location of a replacement soil absorption system.-The replacement <br /> area should be protected from disturbance and compaction and should not be infringed upon by required setbacks from,existing and proposed <br /> structure,lot lines and wells. Failure to protect the replacement area will result in the need.for a new soil and site evaluation to establish a suitable 1 <br /> replacement area. Replacement systems must comply with the rules in effect at the time of their permit issuance. <br /> ❑ A suitable replacement area Is not available due to setback and/or soil limitations, if the soil absorption-system cannot be rehabilitated and barring <br /> advances In POWTS technology,a holding tank may be installed as a last resort. <br /> ❑ The site has not been evaluated to identify@ suitable replacement area.Upon failure of the POWTS_a soil and site evaivatiorrmust be performed to <br /> locate a suitable replacement area.If no.replacemenk-area:ls available a holding lank may be Installed as a last resort to-replace the failed POINTS. <br /> ❑ Mound and at-grade soil absorption systems"may be reconstructed In place following removal of the biomat at the Infiltrative surface. <br /> Reconstructions of such systems must comply with the rules In-effect at that time. <br /> WARNING: TREATMENT TANKS AND HOLDING TANKS MAY CONTAIN POISONOUS GASSES AND LACK SUFFICIENT <br /> �nOXYGEN TO SUPPORT LIFE. NEVER ENTER A TREATMENT TANK OR HOLDING.TANK UNDER ANY <br /> � CIRCUMSTANCE. DEATH MAY RESULT. ESCAPE OR RESCUE FROM THE INTERIOR OF A TANK IS VERY <br /> ` DIFFICULT. <br /> ADDITIONAL INFORMATION: <br /> POWTS INSTALLER POWTS MAINTAINER <br /> Name: STEVEN CROSBY t Name: t <br /> Phone 849-8771 Phone: SAME <br /> SEPTAGE SERVICING OPERATOR(PUMPER) LOCAL REGULATORY AUTHORITY <br /> Name: Name: (MADISON-DANE COUNTY HEALTH <br /> Phone: Phone: 242 I <br /> This document is Intended to meet minimum requirements of Ch. Comm 83.22(2)(b)(1)(d)&(l and 83.54(1), (2)&(3),Wisconsin Administrative Code. <br /> Use of this document does not guarantee the performance of the PUNTS. ' <br />