|
Help
|
About
|
Sign Out
Home
Browse
Search
DCPZP-2016-00582
DaneCounty-Planning
>
Zoning
>
1 Permits
>
2010s
>
2016
>
DCPZP-2016-00582
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/22/2016 9:14:36 AM
Creation date
9/21/2016 12:59:30 PM
Metadata
Fields
Template:
Zoning Permits
AccelaLink
DCPZP-2016-00582
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
.1% i ULIU _Heald} <br /> mArDsom a1laSgwCOUNT( a ____o'- <br /> 1 and'an4a,a POINTS OWNERS MANUAL«.MANAGEMENT PLAN <br /> '=[LE INFORMATION SYSTEM SPECIFIGA I IONS <br /> Duvner�"{ p I Tank Manu ec*irar t4E tAOa 0 NA <br /> `"'el k& . 16 I E sp5c 0 Dose 9 Kaki Volume Ptte ga�1 <br /> Pernik t PQ i S; 1 Tank Manufacturer: M 0 c 9 NAJ <br /> _ j L1 S c Dose 9 Holds= Volume (0 50 gall DESIGN PARAMETERS Verncat bisiaxe Tank Botfom(s)toSetvicPart t5 LL <br /> 1 Number cd Bedrooms 4 0 NA Hatzonta[Distance Tanks)to Service Pad: 15 O s <br /> Number fit Public Facidltr Units 0 NA Specific servicing mechanics must be provide u minima is>15 feet or V <br /> Estimated(averaca)Roar. q D 0 qeeday horiim fal is>150 fast SpecMo instructions on plan addendum_ <br /> [Oesfign(p )Flow=es tadaT. : Cg OD ssrr <br /> In Situ Soil Applica5on Rate: _asUdSYFr?j t f riser ivfanuf r er C}R E N CO I <br /> Standard Domestichlfluenf tram 1oritifyaverage EuentFilterModel FT <br /> Vats, Grits(FOG) A0 matL Pump Manufacturer:rrer (� DNA Biocha al Oxygen Demand(}ors inn Man- <br /> Total gr DNA Pump Model -PU4(1 q"C <br /> Suspended Sri rem) aim mgfL 1Pr bT ri Unit <br /> Stah Strength IneturseJEnthera hiorrthly average ManalectureE 1 <br /> Fate.Oil&Grease(FOG) >30i mei 1 0 Mechanical Aeraeam ❑Peat Filter I <br /> arocimn=C2t Oxygen Demand(BOW >220 mglL (t NA - 0 Disinfect on 0 Weiland G I NA) <br /> Total Suspended Golds fr8G) >15D MO- 0 SandiGtavei Filter 0 o6rar_ <br /> Rab-eatad Effluent Monthly average Sol Absoiptluu System t <br /> 8iocrerdcar Oxygen Demand(BQDe) ail mgr! f! a In-Ground(gravity) Q in-Ground(pressure) 0 NA I <br /> Total Sus�aied Sonde(i SSl s30 mat_ 3 fist l 0 Ai-Grade Mound <br /> 'Fecal Corm=tgamneiic nee) sW caiiourd ( 0 Drip-line El Mien <br /> t(f Magnum afferent Paredes Seer .Is IT d a. 9 M ) <br /> }Other. g NA 1 I Other. IA NA} <br /> ii <br /> I MAINTENANCE SGIIEDULE - <br /> tService Event i Service Frerprancy 1 <br /> 4 Piano out mt am 1 itS of tank(s) <br /> " 1 Q When combined sludge and fin equals one-third(413)o nkvolur . i • <br /> j 0 When The high',debar alarm is a va58d. I <br /> IInspect condition of tank(s) i At t once way 3 years- L.NA 1 <br /> !Inspect dispersat cebs(s) 1 t least(ncevety3 years. - 0 NA1 <br /> Clean effluentlitter :PEA 9 NA <br /> Inspe tplump,pump coniaois alarm 1 - 0 l IA <br /> UJpp Rs puAA17au Ai,Atz_vvter) i <br /> Ffusim Ietenals and Pressure tee I L�YS L( ti l= N A 0 NA 1 <br /> Otfler. I L <br /> 1 i <br /> I Other: 1 0 NA f <br /> MAINTENANCE INSTRUCTIONS <br /> I soectas of tanks and dispemai calls shell be made by al kdUIdnN taaiying one Qi Me ticwing Imes or calficadenx Master Plumber,Ades='.*- <br /> Ptrmnbar Re biclad Server POWre I>speciar,POWT$Maintainer;Sepmge servicing Operator(pampa)_Tank Imp86ROna IIai6t 8ulcrde a%twig <br /> baperdon afit a tinkle)to Mary any r„b,anpr arbroken hardware.idenrify any rucks or teaks,mamma the volume of mmblatdskalwa and scum and <br /> a check for any back up or ponding of amt.on ire DroImd smfaca.if The volume of sludge and scum is less than one-third(118)*the squid volume <br /> cells lank.the tank does not need b be pumped and in goo'orvsls aide:lank may notbe possible a<$ 3Rts.Tbe d»culls) <br /> sem be vtsualy Inspected to deck the effluent revels In the abs rv+bran pipes and b check is any pordng of diluent on The Wiled enlace.The <br /> oraSluent on the ground...awe mayin:S alarms m,4I&,nand cequkae ere Immediate noffacesfica easemarlrosymewdly- <br /> When the combined accomelarnm ofsiudge and scam in any Irealmentlatk equals one•third(113)or more of The tank volane.the et&re ammonia of the <br /> tank shall be removed by a Septatge Servicing operator and r>sposed din accordancewilfr NR 1't3,Wisconsin Administrative Code. <br /> aaasw•rowrSMssceaad� <br />
The URL can be used to link to this page
Your browser does not support the video tag.