Laserfiche WebLink
Page/of, <br /> • POWTS OWNER'S MANUAL & MANAGEMENT PLAN <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> Owner: Tank Manufacturer: D4)ri.f.y 0 NA <br /> 0150r) R' an ®Septic 0 Dose ❑Holding Volume gal <br /> Permit: / POWTS# Tank Manufacturer. bet I iiorny 0 NA <br /> ❑Septic ®Dose ❑Holding Volume , gal <br /> DESIGN PARAMETERS Vertical Distance Tank Bottom(s)to Service Pad: ICI ft <br /> Number of Bedrooms: 11 ❑NA Horizontal Distance Tank(s)to Service Pad: 106 ft <br /> Number of Public Facility Units: • l J NA Specific servicing mechanics must be provide if vertical is>15 feet or If <br /> Estimated(average)Flow: a 0 d gal/day hortzonllwl Is>150 feet.Specific Instructions on plan addendum. <br /> Design(peak)Flow a estimate('x 1.5: b 0 0 • gal/day <br /> In Situ Soil Application Rate: , Li gaVday/fts Effluent Filter Manufacturer ❑NA <br /> Standard Domestic Influent/Effluent Monthly average Effluent Filter Model: 5 r„, Tt c H 5 Tr 100 <br /> Fats,Oil 8 Grease(FOG) 430 mg/L Pump Manufacturer: co,el05 , ❑ NA <br /> Biochemical Oxygen Demand(BOO.) 5220 mg/L ❑NA Pump Model: aeo 3 rl[, <br /> Total Suspended Solids(TSS) 5150 mg/L • Pretreatment Unit <br /> High Strength Influent/Effluent Monthly average Manufacturer: <br /> Fats,Oil&Grease(FOG) >30 mg/L . • ❑Mechanical Aeration ❑Peat Filter <br /> Biochemical Oxygen Demand(BOD.) >220 mg/L ®NA ❑Disinfection ❑Wetland Er NA <br /> Total Suspended Solids(TSS) >150 mg/L ❑Sand/Gravel Filter ❑Other: <br /> Pretreated Effluent • Monthly average Soil Absorption System <br /> Biochemical Oxygen Demand(BOD.) 530 mg/L A In-Ground(gravity) 0 In-Ground(pressure) ❑ NA <br /> Total Suspended Solids(TSS) 530 mg/L ®NA ❑At-Grade 0 Mound <br /> Fecal Conform(geometr a mean) 5104 cfu/100m1 ❑Drip•Llne ❑Other: <br /> Maximum Effluent Particle Size: 1/8 In die. ❑NA <br /> Other: %. NA Other: El NA <br /> • <br /> • <br /> MAINTENANCE SCHEDULE <br /> Service Event Service Frequency ' • <br /> rig When combined sludge and scum equals one-third(1/3)of tank volume. <br /> Pump out contents of tank(s) <br /> Ea the high water alarm is activated. <br /> Inspect condition of tank(s) At leant once very 3 years. ❑NA <br /> Inspect dispersal cells(s) At least once very 3 years. ❑NA <br /> Clean effluent filter " ❑NA <br /> Inspect pump,pump controls&alarm One,r 4. dear ❑NA <br /> Flush laterals and pressure test ietknn A r 0 NA <br /> Other: C.1•• <br /> Other: <br /> MAINTENANCE INSTRUCTIONS <br /> Inspections of tanks and dispersal cells shall be made by an Individual carrying one of the following licenses or certifications:Master Plumber,Master <br /> Plumber Restricted Sewer, POWT8 inspector, POWTS Maintainer,Septage Servicing Operator(pumper).Tank Inspections must Include a visual ' <br /> inspection of the tank(s)to Identify any missing or broken hardware,Identify any sacks or leaks,measure the volume of combined sludge and scum and <br /> a check for any back up or ponding of effluent on the ground surface.The dispersal cell(s)shall be visually Inspected to check the effluent levels in the <br /> observation pipes and to check for any ponding of effluent on the ground surface.The ponding of effluent on the ground surface may Indicate a falling <br /> condition and requires the Immediate notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum In any treatment tank equals one-third(1/3)or more of the tank volume,the entire contents of the , <br /> tank shall be removed by a Septage Servicing Operator and disposed of In accordance with chapter NR 113,Wlsoonsln Administrative Code. <br /> All other services, Including but not limited to the servicing of effluent filters, mechanical or pressurized components, pretreatment units, and any <br /> servicing at Intervals of s12•months,shall be performed bye certified POWTS Maintainer, <br /> srinooi!•POWTSpt.n.doo <br />