Laserfiche WebLink
t <br /> •� js <br /> • Page_Z.of <br /> A service report shall be provided to the local regulatory authority within 30 days of completion of any service event. <br /> STARTUP AND OPERATION <br /> For new construction,prior to use of the POWTS deck treatment tank(s)for the presence of painting products,solvents or other chemicals or sediment <br /> that may Impede the treatment process and/or damage the soil absorption cell(s).If high concentrations are detected have the contents of the tank(s) <br /> removed by a septage servicing operator prior to use. <br /> System start up shall not occur when soil conditions are frozen at the intiitrative surface. <br /> Owing extended power outages pump tanks may till above normal hlghwater levels.When power Is restored the excess wastewater will be discharged <br /> to-the dispersal celi(s)in ofte large dose and may overload them resulting In the backup or surface discharge of effluent To avoid this situation have the <br /> contests of the pump lank removed by a Septage Servicing Operator prior to restoring power to the effluent pump or contact oa Plumber or POWTS <br /> Maintainer to assist In manually operating the pump controls to restore normal levels within the pump tank. <br /> Do not drtve or park vehicles over tanks and disposeral cells.Do not drive or park over,or otherwise disturb or compact,the area within 15 feet down <br /> slope of any mound or at-grade soil absorption area. <br /> Reduction or elimination of the following from the wastewater stream may Improve the p*rforrnance and prolong the life of the POWTS:antibiotics,baby <br /> wipes,cigarette butts,condoms,cotton swabs,degreasers,dental floss,diapers,disinfectants,fat,foundation drain(sump pump)discharge,fruit and <br /> vegetable peelings,gasoline,greases,herblddes,meat scraps,medications,oils,painting products,pesticides,sanitary napkins, tampons,and water <br /> softener brine. <br /> ABANDONMENT <br /> When the POWTS fails and/or is permanently taken out of service the following steps shall be taken to insure that the system is property and safely <br /> abandoned In compliance with s.Comm 83.33,Wisconsin Administrative Code: <br /> • Ali piping to tanks,pits and othersottabsorption systems shall be disconnected and the abandoned pipe openings sealed. <br /> • The contents of all tanks and pits shall be removed and properly disposed of by a Septage Servicing Operator(pumper). <br /> • After pumping,all tanks and pits shall be excavated and removed or their covers removed and the void space filled with soil,gravel or another Inert <br /> soitd material. <br /> • <br /> CONTINGENCY PLAN <br /> if the POWTS falls and cannot be repaired the following measures have been,or must be taken,to provide a code compliant replacement system: <br /> ga A suitable replacement area has been evaluated and may be utilized for the location of a replacement soli absorption system.The replacement <br /> area should be protected from disturbance and compaction and should not be infringed upon by required setbacks from existing and proposed <br /> structure,lot lines and wells.Failure to protect the replacement area will result in the need for a new soil and site evaluation to establish a suitable <br /> replacement area.Replacement systems must comply with the rules In effect at the time of their permit Issuance. <br /> ❑ A suitable replacement area Is not available due to setback and/or soil limitations.If the soil absorption system cannot be rehabilitated and baring <br /> advances in POWTS technology,a holding tank may be Installed as a last resort: <br /> ❑ The site has not been evaluated to identify a suitable replacement area.Upon failure of the POWTS a soil and site evaluation must be performed to <br /> locate a suitable replacement area.If no replacement area is available a holding tank may be Installed as a last resort to replace the failed POWTS. <br /> ❑ Mound and at-grade soil absorption systems may be reconstructed In place following removal of the blomat at the infftratly, surface. <br /> Reconstructions of srxci systems must comply with the rules In effect at that time. <br /> • <br /> WARNING: TREATMENT TANKS AND HOLDING TANKS MAY CONTAIN POISONOUS GASSES AND LACK SUFFICIENT <br /> oeOXYGEN TO SUPPORT LIFE. NEVER. ENTER A TREATMENT TANK OR HOLDING TANK UNDER ANY <br /> CIRCUMSTANCE. DEATH MAY RESULT. ESCAPE OR RESCUE FROM THE INTERIOR OF A TANK IS VERY <br /> ?...4 DIFFICULT. <br /> • ADDITIONAL INFORMATION: <br /> POWTS INSTALLER POWTS MAINTAINER <br /> IName: Leyake So;I Jrs�rn PLC Name: <br /> Phone: 0 R $• 7�-z" I Phone: <br /> • <br /> SEPTAGE•SERVICING OPERATOR(PUMPER) LOCAL REGULATORY AUTHORITY <br /> `Nom: I Name: <br /> Phone: Phone: h baB•ZN Z't<S to <br /> ThIs document Is Intended to meet minimum requirements of Ch.Comm 83.22(2)(bX1Xd)&(f)and 83.54(1),(2)&(3),Wisconsin Administrative Code, <br /> Use of this document does not guarantee the performance of the POWTS. <br /> } <br /> �.dea • <br />