Laserfiche WebLink
• <br /> Page / of, <br /> • POWTS OWNER'S MANUAL & MANAGEMENT PLAN <br /> FILE INFORMATION <br /> Owner: SYSTEM SPECIFICATIONS <br /> I oil Tank Manufacturer: D,I rye.y ❑NA <br /> ® <br /> Permit: Septic ❑Dose ❑Holding Volume gal <br /> POWTS# Tank Manufacturer: Om I N,arn y ❑NA <br /> DESIGN PARAMETERS ❑Septic E Dose ❑Holding Volume ,gal <br /> Vertical Distance Tank Bottom(s)to Service Pad: I C) ft <br /> Number of Bedrooms �{ ❑NA Horizontal Distance Tank(s)to Service Pad: I pry ft <br /> Number of Public Facility Units: _ ji0 NA Specific servicing mechanics must be provide If vertical Is>15 feet or If <br /> Estimated(averpge)Flow: 4 0 4 gal/day horizonld Is>150 feet.Specific Instructions on plan addendum. <br /> Design(peak)Flow=estimated x 1.5: b 0 D gal/da <br /> y, <br /> In Situ Soil Application Rate: , � , gal/day/ft= Effluent Filter Manufacturer <br /> Standard Domestic Influent/Effluent Monthly averse ❑NA <br /> Y 6 Effluent Filter Model• <br /> Fats,Oil&Grease(FOG) 130 mg/L w+ T[c H 5 Tr- 10� <br /> Biochemical Oxygen Pump Manufacturer: go,�ldg ❑Nq' <br /> xygen Demand(BODE) 5220 mg/L ❑NA Pump Model: <br /> Total Suspended Solids(TSS) 1150 mg/L we-03W,•High Strength Influent/Effluent Monthly average Manufacturer: <br /> Unit <br /> y g Manufacturer: <br /> Fats,Oil&Grease(FOG) >30 mg/L . 0 Mechanical Aeration ❑Peat Filter <br /> Biochemical Oxygen Demand(BOD,) >220 mg/L ®NA 0 Disinfection <br /> Total Suspended Solids(TSS) >150 mg/L 0 Wetland NA <br /> ❑Sand/Gravel Filter ❑Othe r <br /> Pretreated Effluent • Monthly average Soli Absorption System <br /> Biochemical Oxygen Demand(BODE) 530 mg/L In-Ground ravl <br /> (g lY) 0 In-Ground(pressure) ❑NA <br /> Total Suspended Solids(TSS) 530 mg/L ®NA ❑At-Grade 0 Mound <br /> Fecal Cofiforn(geometric mean) 5104 cfu/1bOml <br /> ❑Drip-Line ❑Other. <br /> Maximum Effluent Particle Size: 1/8 In die. 0 NA <br /> Other: ®NA Other: <br /> ®NA =. <br /> • <br /> MAINTENANCE SCHEDULE <br /> Service Event Service Frequency • <br /> rEj <br /> Pump out contents of tank(s) When combined sludge and scum equals one-third(1/3)of tank volume. <br /> ®When the high water alarm Is activated. <br /> Inspect condition of tank(e) At least once very 3 years. • ❑NA <br /> Inspect dispersal cells(s) At least once very 3 years. ❑NA <br /> Clean effluent filter ii I' <br /> • <br /> ❑NA <br /> Inspect pump,pump controls&alarm Owl a ,}QQi., ❑NA <br /> Flush laterals and pressure test ' 11 ❑NA' <br /> Other: ❑NA <br /> Other: ❑NA <br /> MAINTENANCE INSTRUCTIONS <br /> Inspections of tanks and dispersal cells shell be made by an Individual carrying one of the following licenses or certifications:Master Plumber,Master <br /> Plumber Restricted Sewer, POWTS inspector, POWTS Maintainer, Septage Servicing Operator(pumper). Tank Inspections must Include a visual <br /> Inspection of the tenk(s)to identify any missing or broken hardware,Identify any cracks or leaks,measure the volume of combined sludge and scum and <br /> a cheek for any beck up or pending of effluent on the ground surface.The dispersal cell(e)shall be visually Inspected to check the effluent levels In the <br /> observation pipes reuires the immediate any pending of the local regulatory authority, <br /> The pending of effluent on the ground surface may indicate a falling <br /> condition and ry �,, <br /> When the combined accumulation of sludge and scum In any treatment tank equals one-third(1/3)or more of the tank volume,the entire contents of the , <br /> tank shell be removed by a Septage Servicing Operator and disposed of in accordance with chapter NR 113,Wisconsin Administrative Code. <br /> All other services, Including but not limited to the servicing of effluent filters, mechanical or pressurized components, pretreatment units, and any <br /> servicing at intervals of S12•months,shall be performed by a certified POWTS Maintainer. <br /> 5I1/200e-POWrepr.n.doo <br />