Laserfiche WebLink
Public Health Pageol G, <br /> Hralrhy people and pincr' POWTS OWNER'S MANUAL& MANAGEMENT PLAN <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> Owner: Tank Manufacturer: n,!/c..vz/7l;.,p�' ❑NA <br /> C/t1•-Lim -t«�:� It Septic ❑Dose 0 Holding Volu'me J3 � <br /> gat <br /> Permit: POWTS# Tank Manufacturer: fr[ ❑NA <br /> ❑Septic 0 Dose ❑Holding Volume 6'1 _gal <br /> DESIGN PARAMETERS Vertical Distance Tank Bottom(s)to Service Pad: / _ft <br /> Number of Bedrooms: 3 ❑NA Horizontal Distance Tank(s)to Service Pad: /,10 ft <br /> Number of Public Facility Units: 2 NA Specific servicing mechanics must be provide it vertical is>15 feet or if <br /> Estimated(average)Flow _jcz <br /> gal/day horizontal is>150 feet Specific instructions on plan addendum. <br /> Design(peak)Flow=estimated x 1.5: •s, gal/day <br /> In Situ Soil Application Rate t'- gal/day/n2 Effluent Filter Manufacturer ecs ❑NA <br /> Standard Domestic Influent/Effluent Monthly average Effluent Filter Model: Cf."? <br /> Fats.Oil&Grease(FOG) 5530 mg/L Pump Manufacturer: -0 NA <br /> Biochemical Oxygen Demand(BOD5) a220 mg/L ❑NA Pump Model: <br /> Total Suspended Solids(TSS) 5150 mg/L Pretreatment Unit <br /> High Strength Influent/Effluent Monthly average Manufacturer: <br /> Fats.Oil&Grease(FOG) >30 mg/L ❑Mechanical Aeration ❑Peat Filter <br /> Biochemical Oxygen Demand(80D5) >220 mg/L 'NA 0 Disinfection ❑Wetland ❑NA <br /> Total Suspended Solids(TSS) >150 mg/L ❑Sand/Gravel Filter ❑Other: <br /> Pretreated Effluent Monthly average Soil Absorption System <br /> Biochemical Oxygen Demand(BODO) 530 mg/L ❑In-Ground(gravity) ❑In-Ground(pressure) ❑NA <br /> Total Suspended Solids(TSS) 530 mg/L `Cg NA (gAI-Grade ❑Mound <br /> Fecal Coliform(geometric mean) 510'cfu/100m1 ❑Drip-Line ❑Other: <br /> Maximum Effluent Particle Size: 1/8 in dia. ❑NA <br /> Other: 0 NA Other: ❑NA <br /> X/5:5 63 <br /> MAINTENANCE SCHEDULE <br /> Service Event Service Frequency <br /> Pump out contents of tank(s) aWhen combined sludge and scum equals one-third(1/3)of tank volume. <br /> 2 When the high water alarm is activated. <br /> Inspect condition of tank(s) At least once very 3 years. ❑NA <br /> Inspect dispersal cells(s) At least once very 3 years. ❑NA <br /> Clean effluent filter ❑NA <br /> Inspect pump,pump controls&alarm 3 NA <br /> Flush laterals and pressure test ❑NA <br /> Other: E NA <br /> Other: LNA <br /> MAINTENANCE INSTRUCTIONS <br /> inspections of tanks and dispersal cells shall be made by an individual carrying one of the following licenses or certifications:Master Plumber,Master <br /> Plumber Restricted Sewer, POWTS Inspector, POWTS Maintainer,Septage Servicing Operator(pumper). Tank inspections must include a visual <br /> inspection of the tank(s)to identify any missing or broken hardware,identity any cracks or leaks,measure the volume of combined sludge and scum and <br /> a check for any back up or ponding of effluent on the ground surface.If the volume of sludge and scum is less than one—third(1/3)of the liquid volume <br /> of the tank,the tank does not need to be pumped and identifying cracks in floor or walls of the tank may not be possible at that time.The dispersal cell(s) <br /> shall be visually inspected to check the effluent levels in the observation pipes and to check for any ponding of effluent on the ground surface.The <br /> ponding of effluent on the ground surface may Indicate a failing condition and requires the immediate notification of the local regulatory authority <br /> When the combined accumulation of sludge and scum in any treatment tank equals one-third(1/3)or more of the tank volume,the entire contents of the <br /> tank shall be removed by a Septage Servicing Operator and disposed of in accordance with chapter NR 113,Wisconsin Administrative Code. <br /> i;e:2n 10-Cpwlsr;rt;rNen doc <br />