|
Help
|
About
|
Sign Out
Home
Browse
Search
DCPZP-2016-00709
DaneCounty-Planning
>
Zoning
>
1 Permits
>
2010s
>
2016
>
DCPZP-2016-00709
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/8/2016 9:43:08 AM
Creation date
11/7/2016 2:29:38 PM
Metadata
Fields
Template:
Zoning Permits
AccelaLink
DCPZP-2016-00709
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
°r ''PU,blic Health I <br /> 1 <br /> Page _ of S <br /> MADISON Et DANE COUNTY <br /> thalthy people and placer POWTS OWN ER'S MAN UAL& MANAGEMENT PLAN 1 <br /> FILE INFORMATION - SYSTEM SPECIFICATIONS <br /> Owner: , Tank Manufacturer: Me'acQf ❑NA <br /> g I c iw'd MC O#' . [ Septic. ❑.Dose_. ❑ Holding Volume. J R 8?, gal <br /> . Permit: POWTS# Tank Manufacturer: ❑NA <br /> , 0 Septic ❑Dose ❑Holding Volume - - gal <br /> ;*--DESIGN PARAMETERS Vertical Distance Tank Bottom(s)to Service Pad: V ft <br /> Number of Bedrooms: 41 ❑NA Horizontal Distance Tank(s)to Service Pad: S O ft <br /> Number-of Public Facility.Units: ❑NA Specific servicing mechanics must be provide if vertical is>15 feet or If <br /> Estimated(average)Flow: '4 00 gal/day horizontal is>150 feet.Specific Instructions on plan addendum. <br /> Design(peak)Flow.=estimated x 1.5: GO 0 . gal/day . <br /> In Situ Soil Application Rate: 1 14 gal/day/ft2 Effluent Filter Manufacturer 0Y r`i't/(a El NA <br /> Standard Domestic Influent/Effluent Monthly average Effluent Filter Model: 7'O b'EL- / .( 73. I S• <br /> Fats,_oil&Gre.ase(FOG) s3o mg/L. . . . : Pump Manufacturer:• . E3 NA <br /> Biochemical Oxygen Demand(BOD,) 5220 mg/L ❑NA Pump Model: - . <br /> Total Suspended Solids(TSS) 5150 mg/L Pretreatment Unit • <br /> High Strength.Influent/Effluent Monthly average Manufacturer: <br /> Fats,Oil&Grease(FOG) >30 mg/L ❑Mechanical Aeration ❑Peat Filter <br /> Biochemical Oxygen Demand(BOD,) >220 mg/L E NA ❑Disinfection ❑Wetland RNA <br /> Total Suspended Solids(TSS) >150"ing/L - ❑Sand/Gravel Filter ❑Other: <br /> Pretreated Effluent Monthly average -- bsorption System <br /> Biochemical Oxygen Demand(BOD,) 530 mg/L ®In-Ground(gravity) ❑In-Ground(pressure) ❑NA <br /> Total Suspended Solids(TSS) 530 mg/L IR NA ❑At-Grade ❑Mound <br /> Fecal Coliform(geometric mean) 5104 cfu/100m1 ❑Drip-Line ❑Other: <br /> Maximum Effluent Particle Size: 1/81 . ❑NA -. . _ . .• <br /> Other: - . • Et NA Other: • Q NA <br /> . , <br /> MAINTENANCE SCHEDULE <br /> - .. Service Event . .. -. Service Frequency . . : . . <br /> ®When combined sludge and scum equals one-third(1/3)of tank volume. <br /> Pump out contents of tank(s) i <br /> ❑When the high water alarm 1s.activated.; . ( <br /> Inspect condition of tank(s) • At least once very 3 years. ❑NA <br /> Inspect dispersal cells(s) At least Once very 3 years: ❑NA <br /> Clean effluent filter i- ❑NA <br /> a g} em ce A_ e cc.- <br /> Inspect pump,pump controls &alarm @ NA <br /> Flush laterals and pressure test • E$NA <br /> Other: - ga NA <br /> Other: El NA <br /> - l <br /> MAINTENANCE INSTRUCTIONS - - <br /> Inspections of tanks and dispersal cells shall be made by an Individual carrying one of the following licenses or certifications:Master Plumber, Master <br /> Plumber Restricted Sewer, POWTS Inspector, POWTS Maintainer, Septage Servicing Operator (pumper). Tank inspections must include a visual <br /> Inspection of the tanks)to Identify any missing or broken hardware,Identify any cracks or leaks;measure the volume of combined sludge and scum and <br /> a check for any back up or pending of effluent on the ground surface.If the volume of sludge and scum Is less than one—third(1/3)of the liquid volume <br /> of the tank,the tank does not need to be pumped and Identifying cracks In floor or walls of the tank may not be possible at that time.The dispersal cell(s) <br /> shall be visually Inspected to check the effluent levels In the observation pipes and to check for any pending of effluent on the ground surface.The <br /> pending of effluent on the ground surface may Indicate a falling condition and requires the Immediate notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum In any treatment tank equals one-third(1/3)or more of the tank volume,the entire contents of the <br /> tank shall be removed by a Septage Servicing Operator and disposed of In accordance with chapter NR 113,Wisconsin Administrative Code. <br /> 3/e/2010•PO W TSMGTplan.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.