Laserfiche WebLink
° :' <br /> ` Public Health <br /> ' MADISON&DANE COUNTY Page of <br /> Healthy people and placer pOWTS OWNER'S MANUAL& MANAGEMENT=PLAN <br /> FiLE INFORMATION . SYSTEM SPECIFICATIONS <br /> Owner: Tank Manufacturer: (r �.f ❑NA <br /> 23,/L+ t�� �i4.l K S!!S ,' C /13 a Septic. 0.Dose__ "Holding . Volume..- 13©-41- gal <br /> Permit: POWTS# Tank Manufacturer: ❑NA <br /> 0 Septic•❑ Dose. ❑ Holding Volume - • gal <br /> j DESIGN PARAMETERS Vertical Distance Tank Bottom(s)to Service Pad: r?' ft <br /> Number of Bedrooms: ❑ NA Horizontal Distance Tank(s)to Service Pad: . IU ft <br /> Number.of Public Facility.Units: • ❑ NA Specific servicing mechanics must be provide If vertical Is>15 feet or If <br /> Estimated(average)Flow: g yr gal/day horizontal Is>150 feet.Specific Instructions on plan addendum. <br /> Design(peak)Flow.=estimated x 1.5: - • - gal/day .. <br /> In Sltu Soil Application Rate: . gal/day/ftz Effluent Filter Manufacturer • ` -- ❑NA <br /> •Standard Domestic Influent/Effluent Monthly average Effluent Filter Model: — _ = <br /> . • _ Fats;011&Grease(FOG).s30_mg/L. _ . .• Pump Manufacturer:. - ❑NA <br /> Biochemical Oxygen Demand(BON 5220 mg/L ❑NA Pump Model: _ • - - <br /> Total Suspended Solids(TSS) 5150 mg/L Pretreatment Unit <br /> High Strength.Influent/Effluent . Monthly average Manufacturer: • <br /> Fats,Oil&Grease(FOG) >30 mg/L I]Mechanical Aeration . ❑Peat Filter • <br /> Biochemical Oxygen.Demand(BODs) >220 mg/L A . • ❑Disinfection ❑Wetland ❑NA <br /> Total Suspended Solids(TSS) >150-Mg/L. <br /> 150 fng/L • ❑Sand/Graf/el Filter ❑Other: - <br /> Pretreated Effluent Monthly average - ' Soil Absorption System.. <br /> Biochemical Oxygen Demand(BOD,) 530 mg/L ❑In-Ground(gravity) ❑In-Ground(pressure) ' ❑NA <br /> Total Suspended Solids(TSS) 539mg/L TiA ❑At-Grade ❑Mound • <br /> Fecal Colifomi(geometric mean) 5104 cfu/lOUmI ❑Drip-Line ❑Other: <br /> Maximum Effluent Particle Size: . .-1/8 India. ❑ NA .. . . . . <br /> Other: -❑NA Other: " . • • - 0 NA <br /> MAINTENANCE SCHEDULE .• . • <br /> • . Service Event • _ • - . .. .. . Service Frequency . : . • . . : . . <br /> Pump out contents of tank(s) ❑When.combined sludge.and scum equals one-third(1/3)of tank volume. -- •. - . <br /> V'•When the high water alarm Is.activated.:. ., . . . ,• <br /> Inspect condition of tanks) ; At least once very 3 years. 0 NA <br /> Inspect dlspersel.cells(s) At least once very 3 years: DNA•• <br /> Clean•effluent filter ❑NA <br /> Inspect pump, pump controls &alarm - • ❑NA <br /> • <br /> Flush laterals and pressure test • ❑NA <br /> Other: ❑NA <br /> Other: ❑NA <br /> MAINTENANCE INSTRUCTIONS • - •• <br /> Inspections of tanks and dispersal cells shall be made by an Individual carrying one of the following licenses or certifications:Master Plumber,Master <br /> Plumber Restricted Sewer, POWTS Inspector, POWTS Maintainer, Septage Servicing Operator (pumper). Tank Inspections must Include a visual <br /> inspection of the tank(s)to Identify any missing or broken hardware,Identify any cracks or leaks;measure the volume of corribined sludge and scum and <br /> a check for any back up or ponding of effluent on the ground surface.If the volume of sludge and scum Is less than one—third(1/3)of the liquid volume <br /> of the tank,the tank does not need to be pumped and Identifying cracks In floor or walls of the tank may not be possible at that lime.The dispersal cell(s) <br /> shall be visually Inspected to check the effluent levels In the observation pipes and to check for any ponding of effluent on the ground surface.The <br /> ponding of effluent on the ground surface may Indicate a falling condition and requires the Immediate notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum In any treatment tank equals one-third(1/3)or more of the tank volume,the entire contents of the <br /> tank shall be removed by a Septage Servicing Operator and disposed of in accordance with chapter NR 113,Wisconsin Administrative Code. <br />