1 Permits
>
2010s
>
2016
>
DCPZP-2016-00773
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2016 11:14:10 AM
Creation date
12/8/2016 3:31:13 PM
Metadata
Fields
Template:
Zoning Permits
AccelaLink
DCPZP-2016-00773
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
• <br /> POWTS OWNER'S MANUAL & MANAGEMENT PLAN Page of <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> Owner A n ic w i 1 d, a h._ Tank Manufacturer: 9 g ❑ NA <br /> Permit# H Septic ❑ Dose ❑ Holding Volume: Pa& (gal) <br /> • <br /> DESIGN PARAMETERS Tank Manufacturer: w.....A-17(-- ❑ NA <br /> Number of Bedrooms: .4 ❑ NA ❑ Septic El Dose ❑ Holding Volume: Le 50 (gal) <br /> Number of Public Facility Units: ❑ NA Vertical Distance Tank Bottom(s)to Service Pad: 41 5 (ft) <br /> Estimated (average) Flow: A00 (gauday) Horizontal Distance Tank(s)to Service Pad: 4150 (ft) <br /> Design (peak) Flow=(estimated x 1.5): (gal/day) Specific servicing mechanics must be provided if vertical is>15 feet or <br /> co 00 if horizontal is>150 feet. Specific instructions to be provided on back. <br /> In Situ Soil Application Rate: (galday/ft2) Effluent Filter Manufacturer: 01200 CO <br /> ❑ NA <br /> Standard(Domestic) Influent/Effluent Monthly average Effluent Filter Model: F-1-6 <br /> Fats,Oil&Grease (FOG) 5530 mg/L Pump Manufacturer: Ot.ouLoS <br /> Biochemical Oxygen Demand (BOD5) 5220 mg/L ❑ NA ❑ NA <br /> Total Suspended Solids(TSS) 5150 mg/L Pump Model: E P041 F AC- <br /> High Strength Influent/Effluent Monthly average Pretreatment Unit <br /> (FOG) >30 mg/L Manufacturer. <br /> (BOD5) >220 mg/L ® NA fs NA <br /> (TSS) >150 mg/L ❑ Mechanical Aeration ❑ Peat Filter <br /> ❑Disinfection ❑Wetland <br /> Pretreated Effluent Monthly average ❑Sand/Gravel Filter ❑Other. <br /> (BOD5) 530 mg/L Soil Absorption System <br /> (TSS) 530 mg/L ❑ NA <br /> Fecal Coliform(geometric mean) 5104 ❑ In-Ground(gravity) ❑ In-Ground(pressure) ❑ NA <br /> Maximum Effluent Particle Size '�in dia. 'El NA ❑At-Grade 0 21 Mound <br /> Other <br /> ❑Drip-Une ❑Other. <br /> Other: ® NA Other: M NA <br /> MAINTENANCE SCHEDULE <br /> Service Event Service Frequency <br /> Pump out contents of tank(s) ❑ When combined sludge and scum equals one-third(1 )of tank volume <br /> ❑ When the high water alarm is activated <br /> Inspect condition of tank(s) At least once every: ❑month(s) (Maximum 3 years) ❑ NA <br /> ❑year(s) <br /> Inspect dispersal cell(s) At least once every: ❑month(s) (Maximum 3 years) ❑ NA <br /> ❑year(s) <br /> Clean effluent filter At least once every: ❑month(s) `, ❑ NA <br /> ❑year(s) �1 EA12Ly <br /> Inspect pump, pump controls&alarm At least once every: ❑month(s) `, ' NA <br /> ❑year(s) K �4 !-1 RAM M P E 4 / l A 2 f�tE9❑ <br /> Flush laterals and pressure test. At least once every: ❑month(s) P1-5 t•I�E-O E0 ❑ NA <br /> ❑year(s) <br /> Other: At least once every: ❑month(s) NA <br /> ery: ❑year(s) <br /> ❑ <br /> Other. <br /> ❑ NA <br /> VIAINTENANCE INSTRUCTIONS <br /> Inspections of tanks and soil absorption systems shall be made by an individual carrying one of the following licenses or certifications: <br /> Master Plumber, Master Plumber.Restricted Sewer, POWTS Inspector, POWTS Maintainer or Septage Servicing Operator (pumper). <br /> Tank inspections must include a visual inspection of the tank(s) to identify any missing or broken hardware, identify any cracks or leaks, <br /> measure the volume of combined sludge and scum and a check for any back up or ponding of effluent on the ground surface. The soil <br /> absorption system shall be visually inspected to check the effluent levels in the observation pipes and to check for any ponding of effluent <br /> on the ground surface. The ponding of effluent on the ground surface may indicate a failing condition and requires the immediate <br /> notification of the local regulatory authority. _. <br /> When the combined accumulation of sludge and scum in any treatment tank equals one-third (A) or more of the tank volume, the entire <br /> contents of the-tank-shall be removed by a Septage Servicing Operator (pumper) and disposed of in accordance with chapter NR 113, <br /> Wisconsin Administrative Code. <br /> All other services, including but not limited to the servicing of effluent filters, mechanical or pressurized components, pretreatment units, <br /> and any servicing at intervals of 5_12 months,shall be performed by a certified POWTS Maintainer. <br /> A service report shall be provided to the local regulatory authority within 30 days of completion of any service event. <br /> GMW-005(02/05) <br />
The URL can be used to link to this page
Your browser does not support the video tag.