. ' Public Health <br /> MADISON u DANE COUNTY Page of <br /> Healthy people and places POWTS OWNER'S MANUAL & MANAGEMENT PLAN <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> Owner: 4 r` f� Tank Manufacturer: I/Vara y SM,;f ❑N <br /> ( 1. ' d / i an t. f' t�� ! Septic Dose ❑Holding Volume I '('O .g <br /> Permit: POW S# Tank Manufacturer:P POIl lrlx F=' 0 N <br /> ❑Septic Dose ❑Holding Volume 1 O <br /> ' g <br /> DESIGN PARAMETERS Vertical Distance Tank Bottom(s)to Service Pad: .1,�. <br /> Number of Bedrooms: Li ❑NA Horizontal Distance Tank(s)to Service Pad: ?/7 <br /> Number of Public Facility Units: 2-NA Specific servicing mechanics must be provide if vertical is>15 feet or <br /> Estimated(average)Flow: 0 gal/day horizontal is>150 feet.Specific instructions on plan addendum. <br /> Design(peak)Flow=estimated x 1.5: 00 gal/day <br /> In Situ Soil Application Rate: ... A gal/day/ft2 Effluent Filter Manufacturer Po j y Ia n, 0 N <br /> Standard Domestic Influent/Effluent Monthly average Effluent Filter Model: pL s-,Z <br /> Fats,Oil&Grease(FOG) 530 mg/L Pump Manufacturer: /23 ) S ❑N <br /> Biochemical Oxygen Demand(BOD5) 5220 mg/L ANA Pump Model: 5'f' L.I. kj <br /> Total Suspended Solids(TSS) 5150 mg/L Pretreatment Unit <br /> High Strength Influent/Effluent Monthly average Manufacturer: <br /> Fats,Oil&Grease(FOG) >30 mg/L ❑Mechanical Aeration ❑Peat Filter <br /> Biochemical Oxygen Demand(BOD5) >220 mg/L kl NA ❑Disinfection ❑Wetland rl-N <br /> Total Suspended Solids(TSS) >150 mg/L ❑Sand/Gravel Filter ❑Other: /R' <br /> Pretreated Effluent Monthly average Soil Absorption System <br /> Biochemical Oxygen Demand(BOD5) 530 mg/L At In-Ground(gravity) ❑In-Ground(pressure) ❑N <br /> Total Suspended Solids(TSS) 530 mg/L irNA ❑At-Grade ❑Mound <br /> Fecal Coliform(geometric mean) 5104 cfu/100m1 ❑Drip-Line ❑Other: <br /> - <br /> Maximum Effluent Particle Size: 1/8 in dia. ❑ NA <br /> Other: ❑ NA Other: ❑ N <br /> MAINTENANCE SCHEDULE <br /> Service Event Service Frequency <br /> Pump out contents of tank(s) .®'When combined sludge and scum equals one-third(1/3)of tank volume. <br /> g When the high water alarm is activated. <br /> Inspect condition of tank(s) At least once very 3 years. ❑NPI <br /> Inspect dispersal cells(s) At least once very 3 years. ❑N <br /> Clean effluent filter <br /> �t/f a5`T one. '. Ef/i_t-) YYS ❑ N <br /> Inspect pump,pump controls&alarm ^3 //�j ❑N <br /> Flush laterals and pressure test NAI <br /> Other: <br /> ❑NAB <br /> Other: ❑ NA <br /> MAINTENANCE INSTRUCTIONS <br /> Inspections of tanks and dispersal cells shall be made by an Individual carrying one of the following licenses or certifications:Master Plumber, Master <br /> Plumber Restricted Sewer, POWTS Inspector, POWTS Maintainer, Septage Servicing Operator (pumper). Tank inspections must include a visual <br /> inspection of the tank(s)to identify any missing or broken hardware,Identify any cracks or leaks,measure the volume of combined sludge and scum and <br /> a check for any back up or ponding of effluent on the ground surface.If the volume of sludge and scum is less than one—third(1/3)of the liquid volume <br /> of the tank,the tank does not need to be pumped and identifying cracks in floor or walls of the tank may not be possible at that time.The dispersal cell(s) <br /> shall be visually Inspected to check the effluent levels in the observation pipes and to check for any ponding of effluent on the ground surface. The <br /> ponding of effluent on the ground surface may indicate a failing condition and requires the immediate notification of the local regulatory authority. <br /> I <br /> When the combined accumulation of sludge and scum in any treatment tank equals one-third(1/3)or more of the tank volume,the entire contents of the 1 _ <br /> tank shall be removed by a Septage Servicing Operator and disposed of in accordance with chapter NR 113,Wisconsin Administrative Code. <br /> 1 <br /> i <br /> 4/29/2016-POWTSMGTplan.doc <br /> i <br />
The URL can be used to link to this page
Your browser does not support the video tag.