Help
|
About
|
Sign Out
Home
Browse
Search
DCPZP-2017-00002
DaneCounty-Planning
>
Zoning
>
1 Permits
>
2010s
>
2017
>
DCPZP-2017-00002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/9/2017 4:12:17 PM
Creation date
1/9/2017 1:02:04 PM
Metadata
Fields
Template:
Zoning Permits
AccelaLink
DCPZP-2017-00002
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
POWTS OWNER'S MANUAL & MANAGEMENT PLAN Page_of_ <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> Owner �A,ILIA Annf 3-E/.1Nk FErZ- GIUICSKF Tank Manufacturer: 1..A.E.A0E ❑ NA <br /> Permit# El Septic ❑Dose ❑Holding Volume: 1.,..0(p (gal) <br /> DESIGN PARAMETERS Tank Manufacturer: MEl4OE- ❑NA <br /> Number of Bedrooms: 4 ❑NA ❑Septic fn Dose ❑Holding Volume: (DSO (gal) <br /> Number of Public Facility Units: Et NA Vertical Distance Tank Bottom(s)to Service Pad: 4 IS (ft) <br /> Estimated(average)Flow: <100 (gauday) Horizontal Distance Tank(s)to Service Pad: L15 O (ft) <br /> Design(peak)Flow=(estimated x 1.5: Specific servicing mechanics must be provided if vertical is>15 feet or <br /> 9 (P ) ( ) (I QQ (gauday) if horizontal is>150 feet. Specific instructions to be provided on back. <br /> In Situ Soil Application Rate: ,.=-/ (gal/day/ft2) Effluent Filter Manufacturer: 012.er-NCO <br /> ❑NA <br /> Standard(Domestic)Influent/Effluent Monthly average Effluent Filter Model: ETD <br /> Fats,Oil&Grease (FOG) s30 mg/L Pump Manufacturer: (rta.ALtS <br /> Biochemical Oxygen Demand (BODs) s220 mg/L ❑NA ❑NA <br /> Total Suspended Solids(TSS) s150 mg/L Pump Model: E-F 0 41(l/N,C <br /> High Strength Influent/Effluent Monthly average Pretreatment Unit <br /> (FOG) >30 mg/L Manufacturer: <br /> (BOW >220 mg/L t=1 NA E NA <br /> (TSS) >150 mg/L ❑Mechanical Aeration ❑Peat Filter <br /> ❑Disinfection ❑Wetland <br /> Pretreated Effluent Monthly average ❑Sand/Gravel Filter ❑Other. <br /> (Boos) s30 mg/L Soil Absorption System <br /> (TSS) s30 mg/L gl NA <br /> Fecal Coliform(geometric mean) s104 ❑In-Ground(gravity) ❑In-Ground(pressure) ❑NA <br /> ❑At-Grade ❑Mound • <br /> Maximum Effluent Particle Size kin dia. ❑NA .❑Drip-Une ❑Other. <br /> Other: to NA Other: IS NA <br /> MAINTENANCE SCHEDULE <br /> Service Event Service Frequency <br /> Pump out contents of tank(s) ❑When combined sludge and scum equals one-third(A)of tank volume <br /> ❑When the high water alarm is activated . <br /> Inspect condition of tank(s) At least once every: ❑month(s) (Maximum 3 years) ❑NA <br /> ❑year(s) <br /> Inspect.dispersal cell(s) At least once every:. ❑month(s) (Maximum 3 years) ❑ NA <br /> ❑year(s) - <br /> Clean effluent filter At least once every: ID month(s) ❑NA <br /> ❑year(s) .q EARL,-( <br /> Inspect pump,pump controls&alarm At least once every: ❑month(s) A ❑NA <br /> ❑year(s) \til6t�N (�u M PEO ALA2MED <br /> Flush laterals and pressure test. - At least once every: ❑manth(s) 0 <br /> ❑year(s) <br /> Other: . ❑month(s) <br /> At least once every: ❑years) ❑NA <br /> Other <br /> . ❑NA <br /> MAINTENANCE INSTRUCTIONS <br /> Inspections of tanks and soil absorption systems shall be made by an individual carrying one of the following licenses or certifications: <br /> Master Plumber, Master Plumber Restricted Sewer, POWTS Inspector, POWTS Maintainer or Septage Servicing Operator(pumper). <br /> Tank inspections must include a visual inspection of the tank(s)to identify any missing or broken hardware,identify any cracks or leaks, <br /> measure the volume of combined sludge and scum and a check for any back up or ponding of effluent on the ground surface. The soil <br /> absorption system shall be visually inspected to check the effluent levels in the observation pipes and to check for any ponding of effluent <br /> on the ground surface.- The ponding of effluent`on the ground surface may indicate a failing condition and requires the immediate <br /> notification of the local regulatory authority. , <br /> When the combined accumulation of sludge and scum in any treatment tank equals one-third(h)or more of the tank volume,the entire <br /> contents of the-tank-shall-be removed by a Septage Servicing Operator-(pumper)and disposed of in accordance with chapter NR 113, <br /> Wisconsin Administrative Code. <br /> All other services,including but not limited to the servicing of effluent filters,mechanical or pressurized components,pretreatment units, <br /> and any servicing at intervals of<_12 months,shall be performed by a certified POWTS Maintainer. . <br /> A service report shall be provided to the local regulatory authority within 30 days of completion of any service event. <br /> GMW-005(02/05) <br />
The URL can be used to link to this page
Your browser does not support the video tag.