|
Help
|
About
|
Sign Out
Home
Browse
Search
DCPZP-2017-00005
DaneCounty-Planning
>
Zoning
>
1 Permits
>
2010s
>
2017
>
DCPZP-2017-00005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2017 3:32:01 PM
Creation date
1/19/2017 3:31:57 PM
Metadata
Fields
Template:
Zoning Permits
AccelaLink
DCPZP-2017-00005
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Public Health Page`jlq of / <br /> Hcohhr.people and plocrr POWTS OWNER'S MANUAL & MANAGEMENT PLAN <br /> 'ILE INFORMATION SYSTEM SPECIFICATIONS <br /> )wner. , Tank Manufacturer. NA <br /> f�✓/Lc1.9M r' 4"/ _ L���`.J 5.7 r Septic ❑ Dose ❑ Holding Volume • wr' gal <br /> 'ermit: POVVTS# Tank Manufacturer: E NA <br /> ❑ Septic ❑ Dose ❑ Holding Volume gal <br /> )ESIGN PARAMETERS Vertical Distance Tank Bottom(s)to Service Pact /y ft <br /> Number of Bedrooms: y ❑ NA Horizontal Distance Tank(s)to Service Pad: ____,4111C, ft <br /> Number of Public Facility Units ® NA Specific servicing mechanics must be provide if vertical is >15 feel or if <br /> Estimated(average)Flow Y � gal/day horizontal is>150 feet.Specific instructions on plan addendum. <br /> Design(peak)Flow= estimated x 1.5. 61� gal/day <br /> In Situ Soil Application Rate: a- fl gal/day/ft' Effluent Filter Manufacturer Q ❑ NA <br /> Standard Domestic Influent/Effluent Monthly average Effluent Filter Model; 6->=7-47 <br /> Fats.Oil&Grease(FOG) 530 mg/L Pump Manufacturer. to NA <br /> Biochemical Oxygen Demand(BOD5) 5220 mg/L ❑ NA Pump Model: <br /> Total Suspended Solids(TSS) 5.150 mg/L Pretreatment Unit <br /> ligh Strength Influent/Effluent Monthly average Manufacturer: <br /> Fats,Oil&Grease(FOG) >30 mg/L ❑Mechanical Aeration ❑Peat Filter <br /> Biochemical Oxygen Demand(BOD5) >220 mg/L lig NA ❑Disinfection ❑Wetland ] NA <br /> Total Suspended Solids(TSS) >150 mg/L ❑Sand/Gravel Filter ❑Other- <br /> )retreated Effluent Monthly average Soil Absorption System <br /> Biochemical Oxygen Demand(BOD5) 530 mg/L In-Ground(gravity) ❑In-Ground(pressure) ❑ NA <br /> Total Suspended Solids(TSS) 530 mg/L IZI NA ❑Al-Grade ❑Mound <br /> Fecal Coliform(geometric mean) 5104 cfu/100m1 ❑Drip-Line ❑Other: <br /> Maximum Effluent Particle Size: 1/8 in dia. ❑ NA <br /> Uther: ® NA Other: ' NA <br /> MAINTENANCE SCHEDULE <br /> Service Event Service Frequency <br /> Pump out contents of tank(s) 2 When combined sludge and scum equals one-third(1/3)of tank volume. <br /> [21 When the high water alarm is activated. <br /> Inspect condition of tank(s) At least once very 3 years. ❑ NA <br /> Inspect dispersal cells(s) At least once very 3 years. ❑ NA <br /> Clean effluent filter ❑ NA <br /> Inspect pump, pump controls&alarm ® NA <br /> Flush laterals and pressure test s] NA <br /> Other: NA <br /> Other: 0 NA <br /> MAINTENANCE INSTRUCTIONS <br /> Inspections of tanks and dispersal cells shall be made by an individual carrying one of the following licenses or certifications:Master Plumber, Master <br /> Plumber Restricted Sewer, POWTS Inspector, POWTS Maintainer. Septage Servicing Operator (pumper). Tank inspections must include a visual <br /> inspection of the tank(s)to identify any missing or broken hardware,identify any cracks or leaks,measure the volume of combined sludge and scum and <br /> a check for any back up or ponding of effluent on the ground surface.If the volume of sludge and scum is less than one-third(1/3)of the liquid volume <br /> of the tank,the tank does not need to be pumped and identifying cracks in floor or walls of the tank may not be possible at that time.The dispersal cells) <br /> shall be visually inspected to check the effluent levels in the observation pipes and to check for any ponding of effluent on the ground surface. The <br /> ponding of effluent on the ground surface may indicate a failing condition and requires the immediate notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum in any treatment tank equals one-third(1/3)or more of the tank volume,the er ' e contents of the <br /> tank shall be removed by a Septage Servicing Operator and disposed of in accordance with chapter NR 113,Wisconsin Administra ••e. <br /> p;niarowrsia5;rrip <br />
The URL can be used to link to this page
Your browser does not support the video tag.