|
Help
|
About
|
Sign Out
Home
Browse
Search
DCPREZ-0000-03723
DaneCounty-Planning
>
Zoning
>
1 Rezones
>
0000 YR
>
DCPREZ-0000-03723
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2017 1:10:46 PM
Creation date
2/1/2017 1:10:44 PM
Metadata
Fields
Template:
Rezone/CUP
Rezone/CUP - Type
Rezone
Petition Number
03723
Town
Albion Township
Section Numbers
13
AccelaLink
DCPREZ-0000-03723
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
• <br /> (04.441 <br /> .,�; `1a Dane County Public Health Department <br /> titi\ �•f 1206 NORTHPORT DRIVE, ROOM 107• MADISON,WISCONSIN 53704-2088 • PHONE (608) 241-4481 <br /> Division of Environmental Health <br /> DIVISION OF ADMINISTRATION July 25, 19 8 6 Orville W.Hintz,R.S. <br /> Director <br /> Richard L.Crim,M.P.H. <br /> Health Officer <br /> Division of Public Health Nursing <br /> Ann Lemmer Moyer, R.N.,M.S.N. <br /> Harold Hahn Director <br /> N8203 CTH 0 <br /> Waterloo , WI 53594 <br /> REFERENCE : NE' , SE%, Section 13, Town of Albion <br /> Dear Mr. Hahn: <br /> SUBJECT : Onsite Evaluation Results <br /> On July 22 , 1986, I evaluated the soil borings at the <br /> above-referenced location. The results are as follows : <br /> BORING OBSERVED CONDITION <br /> B-1 fcd red mottles below 57 inches ; <br /> the texture of the underlying material <br /> is sandy loam <br /> B-2, B-4 , B-5, B-6 $ B-7 The texture of the underlying <br /> material is sandy loam; otherwise <br /> essentially as described <br /> B-3 fcd red mottles below 68 inches in <br /> the sandy loam <br /> The alternate site as you described it would not be suitable <br /> for a conventional soil absorption system. Wisconsin Administrative <br /> Code ILHR 83 . 10 (2) requires a minimum ". . . 56 inches of suitable <br /> soil from original grade for a conventional soil absorption system." <br /> Please submit a revised 115 . Note that the primary system <br /> must begin upslope of B-5 : the minimum depth for a conventional system <br /> is 18 inches , therefore the ground elevation must be at least <br /> 100. 20 feet for the system elevation of 98 . 70 . <br /> If you have any questions, please feel free to contact me <br /> at 241-4481 between 8 : 00 and 9 : 00 AM Monday through Friday. <br /> Sincerely, <br /> atrice Christianson, R. S. <br /> Senior Sanitarian <br /> DANE COUNTY ENVIRONMENTAL HEALTH DIVISION <br /> PC:md <br />
The URL can be used to link to this page
Your browser does not support the video tag.