Laserfiche WebLink
Public Health Page.Si'of ' <br /> 1-Ico11iri'penplen"'+0"0,5 POWTS OWNER'S MANUAL & MANAGEMENT PLAN <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> Owner: Tank Manufacturer. C/94-C ❑NA <br /> C/ QQCc.s T/.!^/i 4fl. <br /> Septic ❑Dose ❑Holding Volume ��a gal <br /> Permit: POWTS t! Tank Manufacturer: .-1-F4°..4, ❑NA <br /> ❑Septic 21 Dose ❑Holding Volume 6s-4 gal <br /> DESIGN PARAMETERS Vertical Distance Tank Bottom(s)to Service Pad: /$ ft <br /> Number of Bedrooms: 3 ❑NA Horizontal Distance Tank(s)to Service Pact: Al C7. ft <br /> Number of Public Facility Units: 0 NA Specific servicing mechanics must be provide if vertical is>15 feel or if <br /> Estimated(average)Flow 3 ao gal/day horizontal is>150 feet.Specific instructions on plan addendum. <br /> Design(peak)Flow=estimated x 1.5: yS-o gal/day <br /> In Situ Soil Application Rate: p, s gallday/ftz Effluent Filter Manufacturer ZFwEL ❑NA <br /> Standard Domestic Influent/Effluent Monthly average Effluent Filter Model: -r /vo <br /> Fats,Oil&Grease(FOG) 530 mg/L Pump Manufacturer: Guy c,17f ❑NA <br /> Biochemical Oxygen Demand(BOD,) 5220 mg/L ❑NA Pump Model: ///' <br /> Total Suspended Solids(TSS) 5150 mg/L Pretreatment Unit <br /> High Strength Influent/Effluent Monthly average Manufacturer: <br /> Fats,Oil&Grease(FOG) >30 mg/L ❑Mechanical Aeration ❑Peal Filter <br /> Biochemical Oxygen Demand(BODS) >220 mg/L NA ❑Disinfection ❑Welland TIT NA <br /> Total Suspended Solids(TSS) >150 mg/L ❑Sand/Gravel Filter ❑Other <br /> Pretreated Effluent Monthly average Soil Absorption System <br /> Biochemical Oxygen Demand(BOD5) 530 mg/L *In-Ground(gravity) ❑In-Ground(pressure) ❑NA <br /> Total Suspended Solids(TSS) 530 mg/L 2NA ❑At-Grade ❑Mound <br /> Fecal Coliform(geometric mean) 510'cfu/100m1 ❑Drip-Line ❑Other: <br /> Maximum Effluent Particle Size: 1/8 in dia. ❑NA <br /> Other: b3 NA Other: ca NA <br /> MAINTENANCE SCHEDULE <br /> Service Event Service Frequency <br /> Pump out contents of tank(s) 'J When combined sludge and scum equals one-third(1/3)of tank volume. <br /> U When the high water alarm is activated. <br /> Inspect condition of tank(s) At least once very 3 years. ❑NA <br /> Inspect dispersal cells(s) At least once very 3 years. ❑NA <br /> Clean effluent filter ❑NA <br /> Inspect pump,pump controls&alarm ❑NA <br /> Flush laterals and pressure test El NA <br /> Other: ®NA <br /> Other: T'NA <br /> MAINTENANCE INSTRUCTIONS <br /> Inspections of tanks and dispersal cells shall be made by an individual carrying one of the following licenses or certifications:Master Plumber,Master <br /> Plumber Restricted Sewer, POWTS Inspector, POWTS Maintainer. Septage Servicing Operator(pumper). Tank inspections must include a visual <br /> inspection of the tank(s)to identify any missing or broken hardware,identify any cracks or leaks,measure the volume of combined sludge and scum and <br /> a check for any back up or ponding of effluent on the ground surface.If the volume of sludge and scum is less than one-third(1/3)of the liquid volume <br /> of the tank,the tank does not need to be pumped and identifying cracks in floor or walls of the tank may not be possible at that time.The dispersal cells) <br /> shall be visually inspected to check the effluent levels in the observation pipes and to check for any ponding of effluent on the ground surface.The <br /> ponding of effluent on the ground surface may indicate a failing condition and requires the immediate notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum in any treatment tank equals one-third(1/3)or more of the tank volume,the entire contents of the <br /> lank shall be removed by a Septage Servicing Operator and disposed of in accordance with chapter NR 113,Wisconsin Administrative Code. <br /> ue 2n iavowrxi.IG rr,e,,dos <br />