|
Help
|
About
|
Sign Out
Home
Browse
Search
DCPZP-2017-00085
DaneCounty-Planning
>
Zoning
>
1 Permits
>
2010s
>
2017
>
DCPZP-2017-00085
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2017 12:32:52 PM
Creation date
4/4/2017 1:50:44 PM
Metadata
Fields
Template:
Zoning Permits
AccelaLink
DCPZP-2017-00085
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
w', Public Health <br /> MADISON&DANE COUNTY Page of_ <br /> Healtljpeople and places POWTS OWNER'S MANUAL &MANAGEMENT PLAN <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> lOwner Tank Manufacturer. /z° ° ❑NA' <br /> ii it'&'-. .J 5- " eptic ❑Dose ❑Holding Volume gal <br /> (Permit POWTS# Tank Manufacturer. goo ❑NA <br /> 1. ❑Septic /Dose ❑Holding Volume gal <br /> DESIGN PARAMETERS Vertical Distance Tank Bottom(s)to Service Pad: "/S ft <br /> 1 Number of Bedrooms: y ❑NA Horizontal Distance Tank(s)to Service Pad: 415.° ft <br /> Number of Public Facility Units: ( NA Specific servicing mechanics must be provide if vertical Is>15 feet or if <br /> Estimated(average)Flow: `{o° <br /> gal/day horizontal is>150 feet.Specific instructions on plan addendum. <br /> Design(peak)Flow=estimated x 1.5: 6.OL> gai/day <br /> In Situ Soil Application Rate: . 'I gal/day/ft2 Effluent Filter Manufacturer S1 ib. ./ec.Fi3 ❑t�iA <br /> tandard Domestic Influent/Effluent Monthly average Effluent Filter Model: Sj,C/oo <br /> Fats,Oil&Grease(FOG) S30 mg/L Pump Manufacturer. G 0 c...i.cs ❑NA/ <br /> Biochemical Oxygen Demand(BODs) 5220 mg/L ❑NA Pump Model: <br /> Total Suspended Solids(TSS) 5150 mg/L Pretreatment Unit I+ <br /> High Strength Influent/Effluent Monthly average Manufacturer. <br /> Fats,Oil&Grease(FOG) >30 mg/L ❑Mechanical Aeration ❑Peat Filter <br /> Biochemical Oxygen Demand(BODO) >220 mg/L NA ❑Disinfection ❑Wetland ❑NA <br /> Total Suspended Solids(TSS) >150 mg/L ❑Sand/Gravel Filter ❑Other: <br /> Pretreated Effluent Monthly average Soil Absorption System <br /> Biochemical Oxygen Demand(BODs) s30 mg/L ,n-Ground(gravity) ❑In-Ground(pressure) ❑NA <br /> Total Suspended Solids(TSS) 530 mg/L j NA ❑At-Grade CI Mound <br /> Fecal Cofiform(geometric mean) 5104 cfu/100m1 T ❑Drip-Line ❑Other. <br /> Maximum Effluent Particle Size: 1/8 in dia. ❑NA <br /> Other NA Other. ❑NA <br /> LIMINOI <br /> MAINTENANCE SCHEDULE <br /> 1 Service Event Service Frequency <br /> Pump out contents of tank(s) ❑When combined sludge and scum equals one-third(1/3)of tank volume. <br /> ❑When the high water alarm is activated. <br /> Inspect condition of tanks) At least once very 3 years. ❑NA <br /> inspect dispersal cells(s) At least once very 3 years. 0 NA <br /> Clean effluent filter • Yeez r/ ❑NA <br /> Inspect pump,pump controls&alarm 4..A.4--- ,oc1t_.5Z/�-�-•-,-�� ❑NA <br /> Flush laterals and pressure test ❑NA <br /> Other. ❑ NA <br /> Other. ❑NA <br /> MAINTENANCE INSTRUCTIONS <br /> Inspections of tanks and dispersal cells shall be made by an individual carrying one of the following licenses or certifications:Master Plumber,Master <br /> Plumber Restricted Sewer, POWTS Inspector, POWTS Maintainer, Septage Servicing Operator(pumper). Tank inspections must indude a visual <br /> Inspection of the tank(s)to identify any missing or broken hardware,identify any cracks or leaks,measure the volume of combined sludge and scum and <br /> a check for any badc up or pending of effluent on the ground surface.If the volume of sludge and scum is less than one—third(1/3)of the liquid volume <br /> of the tank,the tank does not need to be pumped and identifying cracks in floor or walls of the tank may not be possible at that time.The dispersal cell(s) <br /> shall be visually inspected to check the effluent levels in the observation pipes and to check for any ponding of effluent on the ground surface.The <br /> ponding of effluent on the ground surface may indicate a failing condition and requires the immediate notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum in any treatment tank equals one-third(1/3)or more of the tank volume,the entire contents of the <br /> tank shall be removed by a Septage Servicing Operator and disposed of in accordance with chapter NR 113,Wisconsin Administrative Code. <br /> Sit ZQ1tM0V hM6Tpan.Ml; <br />
The URL can be used to link to this page
Your browser does not support the video tag.