Laserfiche WebLink
17.09(3)(a)—(h) <br /> (3) Standards for development in floodfringe and it meets all of the provisions of subs. <br /> areas. Section 17.07(1) shall apply in addition 17.08(3)(b)1. through 4. and sec. (e)below. <br /> to the following requirements according to the (c) Commercial uses. Any commercial <br /> use requested. structure which is erected, altered or moved <br /> (a) Residential uses. Any habitable into the floodfringe area shall meet the <br /> structure, including a manufactured home, requirements of sub. (a). Subject to the <br /> which is to be erected, constructed, requirements of sub. (e), storage yards, surface <br /> reconstructed, altered or moved into the parking lots and other such uses may be placed <br /> floodfringe area, shall meet or exceed the at lower elevations if an adequate warning <br /> following standards: system exists to protect life and property. <br /> 1. The elevation of the lowest floor, (d) Manufacturing and industrial uses. Any <br /> excluding the basement or crawlway, shall be at manufacturing or industrial structure which is <br /> or above the flood protection elevation on fill. erected, altered or moved into the floodfringe <br /> The fill shall be one foot or more above the area shall be protected to the flood protection <br /> regional flood elevation extending at least 15 elevation using fill, levees, floodwalls, or other <br /> feet beyond the limits of the structure. The flood proofing measures in s. 17.12(5). Subject <br /> department may authorize other floodproofing to the requirements of sub. (f), storage yards, <br /> measures if the elevations of existing streets or surface parking lots and other such uses may <br /> sewer lines makes compliance with the fill be placed at lower elevations if an adequate <br /> standards impractical; warning system exists to protect life and <br /> 2. The basement or crawlway floor may be property. <br /> placed at the regional flood elevation if it is (e) Storage of materials. Materials that are <br /> floodproofed to the flood protection elevation. buoyant, flammable, explosive, or injurious to <br /> No basement or crawlway floor is allowed property,p rty, water quality or human, animal, plant, <br /> `6.`i below the regional flood elevation; fish or aquatic life shall be stored at or above <br /> 3. Contiguous dryland access shall be the flood protection elevation or floodproofed in <br /> provided from a structure to land outside of the compliance with s. 17.12(5). Adequate <br /> floodplain, except as provided in 4. below; and measures shall be taken to ensure that such <br /> 4. In developments where existing street or materials will not enter the water body during <br /> sewer line elevations make compliance with 3. flooding. <br /> above impractical,the zoning administrator may (f) Public utilities, streets and bridges. All <br /> permit new development and substantial utilities, streets and bridges shall be designed <br /> improvements where access roads are at or to be compatible with comprehensive floodplain <br /> below the regional flood elevation, if: development plans;and <br /> a. The zoning administrator has written 1. When failure of public utilities, streets and <br /> assurance from police, fire and emergency bridges would endanger public health or safety, <br /> services that rescue and relief will be provided or where such facilities are deemed essential, <br /> to the structure(s) by wheeled vehicles during a construction of and substantial improvements to <br /> regional flood event;or such facilities may only be permitted if they are <br /> b. The municipality in which the floodproofed in compliance with s. 17.12(5) to <br /> development is located has a natural disaster the flood protection elevation; <br /> plan approved by Wisconsin Emergency 2. Minor roads or non-essential utilities may <br /> Management and the department. be constructed at lower elevations if they are <br /> (b) Accessory structures or uses. designed to withstand flood forces to the <br /> 1. Except as provided in par. 2., an regional flood elevation. <br /> accessory structure which is not connected to a (g) Sewage systems. All on-site sewage <br /> principal structure may be constructed with its disposal systems shall be floodproofed, <br /> lowest floor at or above the regional flood pursuant to s. 17.12(5), to the flood protection <br /> elevation. elevation and shall meet the provisions of all <br /> 2. An accessory structure which is not local ordinances and ch. COMM 83, Wis. <br /> connected to the principal structure and which Admin. Code. <br /> is less than 600 square feet in size and valued (h) Wells. All wells shall be floodproofed, <br /> at less than $10,000 may be constructed with pursuant to s. 17.12(5), to the flood protection <br /> its lowest floor no more than two feet below the elevation and shall meet the provisions of chs. <br /> regional flood elevation if it is subject to flood NR 811 and NR 812, Ws.Admin. Code. <br /> velocities of no more than two feet per second <br /> Page 17-10 <br /> rev.043007 <br />