Laserfiche WebLink
Safety and Buildings <br /> 3824 N CREEKSIDE LA <br /> commerce.Wl.gov HOLMEN WI 54636 <br /> i TDD#:(608)264-8777 <br /> 44 scons i n www.commerce.wi.govisbl <br /> Department of Commerce <br /> www.wisconsin.gov <br /> Jim Doyle,Governor <br /> Jack L.Fischer,A.I.A.,Secretary <br /> CE <br /> May 21,2008 VISIT <br /> CUST ID No. 262474 ATTN: in Buildings&Structures Building g In Spector <br /> SEE <br /> DENNIS S NELSON MUNICIPAL CLERK <br /> NEL-STRUCT LLC TOWN OF SUN PRAIRIE <br /> 2620 STEIN BLVD 5556 TWIN LANE RD <br /> EAU CLAIRE WI 54701 MARSHALL WI 53559-9489 <br /> (Please forward a copy of this letter to the fire <br /> department conducting inspections of this project.) <br /> CONDITIONAL APPROVAL <br /> PLAN APPROVAL EXPIRES: 05/21/2010 Identification Numbers <br /> Transaction ID No. 1535920 <br /> SITE: Site ID No. 737355 <br /> Evergreen Lawncare Please refer to both identification numbers, <br /> 6544 Twin Lane Rd above,in all correspondence with the agency. <br /> Town of Sun Prairie, 53590 <br /> Dane County <br /> FOR: <br /> Facility: 690251 EVERGREEN LAWNCARE <br /> 6544 TWIN LANE RD <br /> SUN PRAIRIE 53590 <br /> Object Type:Building ICC Regulated Object ID No.: 1182376 Code Applies Date: 05/12/08 <br /> Major Occupancy:Storage; Type VB Combustible Unprotected class of construction; New plan; 6,720 project sq ft; <br /> Unsprinklered; Occupancy: S-1 Storage Moderate-Hazard; Component(s)submitted with this transaction:Truss, Roof <br /> Object Type: Truss,Roof Regulated Object ID No.: 1182377 Code Applies Date: 05/12/08 <br /> The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes <br /> and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in <br /> chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements. Only those object <br /> types listed above have been approved;other submittals such as plumbing and those listed below under Also Submit, <br /> may be required. <br /> The following conditions shall be met during construction or installation and prior to occupancy or use: <br /> Also Address <br /> • IBC 1015.1 -Two exit or exit access doorways from any space are required when the occupant load of the space <br /> is greater than the values within Table 1015.1 or when the common path of travel is greater than the limitations <br /> stated in Section 1014.3.Additional exits will be required when the interior dividing wall is installed <br /> creating separate spaces. <br /> Submit <br /> • Comm 61.30(3)-This approval does not include heating,ventilating or air conditioning. The owner should be <br /> reminded that HVAC plans,calculations,and appropriate fees are required to be submitted for review and <br /> approval prior to installation. Our agency offers a number of worksheets and checklists for the Commercial <br /> Building Code at http://commerce.wi.gov/SB/SB-CommBldgPlanRevInfo.html that may assist you in preparing <br /> this submittal.Building Designer should coordinate with HVAC design to avoid problems with clearance to <br /> combustibles,dampers etc. The submitted HVAC plans shall match the approved building plans. Building <br /> Designer is requested to provide a complete set of plans,Energy Calculations and the Building plan review <br />