Laserfiche WebLink
I <br /> II \ <br /> B/RRENKOTT PLOT PLAN Sq. ft of Patio <br /> SURVEYING, INC. 210.1 sq. ft. <br /> P.O. Box 237 Sq. ft of Lot <br /> 1677 N. Bristol Street 14,400 sq. ft. <br /> Sun Prairie, WI. 53590( ) — <br /> Phone 608 8377463 Sq. ft. of Porch <br /> 61.1 sq. ft. <br /> Fax (608) 837-1081 <br /> Sq. ft. Minus House <br /> 10798 sq. ft. <br /> Description: Sq. ft. of Driveway Apron <br /> LOT 65, PIONEER POINTE, LOCATED 153.5 sq. ft. <br /> IN THE NORTHEAST 1/4 OF THE <br /> Prepared for: Sq. ft. of Driveway with Approach <br /> NORTHEAST 1/4, SECTION 30, T7N, and Private Walkway <br /> R8E, TOWN OF MIDDLETON, DANE Tim O'Brien Homes of Madison, LLC 1,676.1 sq. ft. <br /> COUNTY, WISCONSIN. 2601 Crossroads Dr., Suite 140. <br /> SCALE 1" = 30' Madison, WI 53718-7981 All Square Footages are <br /> ' (608) 661-1100 Approximate and Subject to <br /> 0 30 60 Change on Final Construction <br /> N 00°08'26"E 90.00' 20.4E1_ <br /> • <br /> 1 ,0�3_____---__- <br /> _(.1--- \z.,,i. <br /> — <br /> StOCk LOT 65\� <br /> D pile `� o <br /> oh <br /> co h "i <br /> Erosion �� 10' <br /> Control 500. ktop.c1 0.4 <br /> \ CONCRETE <br /> Typical PATIO <br /> \\:r 17.5 - - 23.5' <br /> 24.9'+�yd1 I.\ �, . <br /> 1QT_¢E 174i• .A. <br /> . 9 1QT_ffB- <br /> EPCL10 0�3\ <br /> ` \W <br /> \ <br /> PROPOSED \ <br /> HOUSE 0•›,. <br /> 'N. n PROPOSED T.O.W. 9.5 .-,. \. <br /> ELEv.=(1074.5] 31.5' vi <br /> \ <br /> k i2 C# GARAGE UJ <br /> C N �� ' ^ e <br /> M \\\ DROP GARAGE 8r n ' I <br /> i j N a i3 PORC' 6.6' I` <br /> °p> 10.6' 34.3' r°1''. 10.5• 6 See Previous Sheetfor <br /> 0:, 10.5' 14' I CO <br /> Z % 0 red marked modifications <br /> 10 0 1, --x \- 0 m driveway. <br /> #2/#3, <br /> � ci stone \ <br /> \ <br /> —:—.121--. 'RUN 7\ EASEMENT I k 0 072.0 <br /> --7—� S 00°08'26"W- --- —90.00'_---_ <br /> -N.-CULVERT-4- <br /> —r— <br /> ocii,,,A.._ _JR__,„.., . <br /> .2. <br /> MANISTEE WAY ,3--APPROX. EDGE OF PAVEMENT <br /> ___-_ _ _b_____ <br /> Legend: <br /> —aw—w+— = Approx. Sanitary Sewer Lateral <br /> Location <br /> • = 3/4" Iron Bar (per plat) Qw = Proposed Well <br /> � <br /> XXX.n <br /> k = Proposed Elevations by Builder <br /> Notes: <br /> 0 = Proposed Electric Meter Septic Lateral locations are <br /> © = Proposed Gas Meter approximate and not field <br /> verified. <br /> o = Retaining Wall <br /> c�o <br /> ® = Approx. Utility Pedestal Contours are approximate <br /> U = Window Well from Wyser Grading Plan <br /> Dated: June 28, 2021 Dated: 10/13/2020 <br /> Dated: June 22, 2021 <br /> Dated: March 5, 2021 For your/our protection...have the Building Inspector/Developer sign off on the Plot <br /> Surveyed: (site) Plan accepting the Plan as correctly meeting setback and deed restrictions for <br /> Drawn: B.E.R. the parcel PRIOR to staking. Note: Plot Plan MUST BE APPROVED by the governing <br /> Checked: B.T.S. Municipal Building Authority. ANY staking, without municipal/Developer approval, may be <br /> Approved: D.V.B. subject to change at the client's expense. <br /> Field book: <br /> Comp. File: J:\2020\CARLSON Surveyor has not field verified elevations and can not certify to their accuracy. <br /> Office Map No. 200931 Elevations have been provided and determined by the client. Contractors and excavators <br /> are to field verify and establish site grades. SHEET 1 OF 1 <br />