Laserfiche WebLink
10.04(1)(b)2.—(1)(b)9. <br /> residential use must exist or be under for a reduced size yard setback under s. <br /> construction prior to the erection or placement of 10.16(6). <br /> an accessory building. d. All other accessory buildings less than 120 <br /> 2. Sanitary fixtures are prohibited in square feet in size shall be located not less than <br /> accessory buildings except in agricultural four (4) feet from any side lot line, unless eligible <br /> accessory buildings on zoning lots over 35 acres for a reduced side yard setback under s. <br /> in size, or if required by law, or allowed by a 10.16(6). <br /> conditional use permit. e. Accessory buildings located between the <br /> 3. Size limitations — residential accessory front and rear building lines of a principal <br /> buildings. In the R-Residence districts, the total residence shall conform to the minimum side <br /> gross floor area of all detached accessory yard requirements for principal buildings <br /> buildings shall not exceed one hundred (100%) specified in the respective district regulations of <br /> this ordinance. <br /> of the total building footprint area of the <br /> associated residence. 7. Setback requirements, rear yard. <br /> a. Except on parcels of land over 35 acres in <br /> 4. Lot coverage. No residential building size in the A-1, A-1 EX, and A-3 zoning districts, <br /> together with its accessory buildings on parcels and on parcels in the A-2 and A-4 districts, <br /> between 2 and 35 acres in size in the RH Rural accessory buildings for the housing of livestock <br /> Homes, A-2 Agriculture, A-1 Agriculture, A-1 EX or insects shall be located not less than 50 feet <br /> (Exclusive Agriculture), and A-4 (Small Lot from any rear lot line, unless a greater distance <br /> Agriculture) districts shall cover in excess of 10% is required under sub. (b) of this section, or the <br /> of the lot area. For parcels under 2 acres in size, applicable district regulations of this ordinance. <br /> the lot coverage limitation shall conform to the b. Accessory buildings, cages, kennels, hives <br /> standards in s. 10.05(5), unless a greater lot and runs for housing of animals or insects shall <br /> coverage is permitted under the applicable be located at least 100 feet from an R-1, R-1A, <br /> district regulations of this ordinance. R-2, R-3, R-3A or R-4 Residence District, except <br /> 5. Setback requirements, front yard. Except with respect to existing buildings when the <br /> as provided under section 10.16(4) of this residence district has been created for an <br /> ordinance,.no building, including barns and other existing farm residence or by separating a farm <br /> farm buildings of any description whatsoever, residence from a farm property and the <br /> shall be erected, moved or structurally altered so separated parcel has been rezoned to a <br /> as to be nearer the highway than is prescribed residence district after or at the time of the <br /> by section 10.17. division. <br /> 6. Setback requirements, side yard. c. All other accessory buildings over 120 <br /> a. Except on parcels of land over 35 acres in square feet in size shall be located not less than <br /> size in the A-1, A-1 EX, and A-3 zoning districts, ten (10) feet from any rear lot line, unless eligible <br /> and on parcels in the A-2 and A-4 districts, for a reduced rear yard setback under s. <br /> accessory buildings for the housing of livestock 10.16(6). <br /> or insects shall be located not less than 50 feet d. All other accessory buildings less than 120 <br /> from any side lot line, unless a greater distance square feet in size shall be located not less than <br /> is required under sub. (b) of this section, or the four (4) feet from any rear lot line, unless eligible <br /> applicable district regulations of this ordinance. for a reduced rear yard setback under s. <br /> b. Accessory buildings, cages, kennels, hives 10.16(6). <br /> and runs for housing of animals or insects shall 8. Existing accessory buildings. All <br /> be located at least 100 feet from an R-1, R-1A, accessory buildings lawfully existing as of <br /> R-2, R-3, R-3A, or R-4 Residence District, August 1, 2011 shall be considered a permitted <br /> except with respect to existing buildings when use. Notwithstanding the provisions of secs. <br /> the residence district has been created for an 10.21 and 10.23 regarding nonconforming uses, <br /> existing farm residence or by separating a farm such buildings may be added to, altered, <br /> residence from a farm property and the restored, repaired, replaced or reconstructed, <br /> separated parcel has been rezoned to a provided the locational requirements of the <br /> residence district after or at the time of the district in which the building is located are <br /> division. complied with. <br /> c. All other accessory buildings over 120 9. Permits required. No accessory building <br /> square feet in size shall be located not less than may be erected or placed without first obtaining <br /> ten (10) feet from any side lot line, unless eligible <br /> Page 10-14 <br /> rev. 013116 <br />