Laserfiche WebLink
I <br /> (Sec. 10.16(b) con' t) .- 10-47 <br /> in conformity to the provisions the setback area shall be moved, <br /> of this ordinance. structurally altered or added to _J <br /> (4) Setback, front yard. (a) In so : as to increase that part of <br /> a district in which service sta- the building projecting into the <br /> bons are permitted, pumps and setback area. This provision �' <br /> pump islands may be located with- ishall not be construed to pro- <br /> in the. setback lines, but not hibit additions or alterations l " <br /> closer to the lot line or highway which conform to the setback <br /> right-of-way line, than 12 feet. requirements. <br /> On corner lots no pump or pump (f) Permitted obstructions in a <br /> ~1 <br /> island shal be closer to either required setback area or front �.'> <br /> street or highway than 12 feet. yard. <br /> (b) In case of interior lots 1. - Steps or stoops to provide I <br /> having frontage on two (2) side access to a building that are not <br /> streets, no accessory building more than three (3) feet above <br /> shall extend into the setback ground level and do not extend <br /> area of either street. more than four (4) feet into a I__! <br /> (c) When the side line of an required set back area or yard. _ <br /> interior lot is formed wholly or 2. One story bay windows pro- i ` <br /> in part by the rear line of an jecting three (3) feet or less <br /> abutting corner lot and the into the yard provided that such <br /> street side yard for the main windows do not occupy, in the <br /> building is less than the setback aggregate, more than one-third <br /> from the main building facing (1/3) of the front wall of the <br /> such street, the setback for the building. <br /> building on such interior lot may :I <br /> be modified so as to be midwa (g) On lake front lots, accessory <br /> y buildings may be located in front <br /> between the side yard for the <br /> building on the corner lot and yards subject to the locational r---■, <br /> the setback from such street. requirements of sec. 10.16(6) j � <br /> (a) (1) provided however that the <br /> (d) In platted subdivisions setback requirements are met. - - <br /> recorded before the adoption of <br /> this ordinance where a building (5) Sideyards. (a) Lots of <br /> line shall have been established nonconforming width. <br /> by the construction of buildings 1. On lots 50 feet or more in <br /> on 30 percent of the lots in any width but less that 60 feet, the Ls <br /> one (1) block, such established minimum aggregate side yards <br /> setback line shall be the setback shall be 15 feet and no single -L <br /> for that block, but in no event side yard shall be less than five i '. <br /> shall such setback be less than (5) feet. <br /> 20 feet. <br /> 2. On lots less than 50 feet in <br /> (e) No existing building, erected width the minimum side yard on <br /> prior to the adoption of this each side shall be five (5) feet. <br /> ordinance, which projects into __ <br /> -' <br /> - <br /> Second Quarter, Supp. #9 11/88 <br /> _s <br />