Laserfiche WebLink
„, imi P A02. / ' , N DATE: <br /> ti r ' .4 5/1/14 <br /> GENERAL NOTES AND SPECIFICATIONS 1 DRAWN BY: <br /> I. The materials and labor shown on these plans that are provided by Cleary A. JORENBY <br /> Building Corp. are limited to those materials and labor as defined by the <br /> Cleary Beading Corp. contract. Additional materials or accessories that are (1) CLEARY WEATHERVANE SCALE: ., <br /> not being provided by Cleary Building Corp. may be shown on plans for OWNER LOCATE NONE <br /> context or building code compliance. <br /> SALES SPECIALIST: <br /> 2. All lumber, unless otherwise noted, shall be S4S 02 SPF or better. ZEAL <br /> 3. Lumber embedded in, or in contact with, the ground shall be heated per VERONA <br /> AWPA standards: <br /> REVISIONS: <br /> Embedded in Ground: 0.6 !befit' retention _ NO. DATE BY <br /> Ground Contact: 0.4 Ibs/ft' retention ' <br /> 1 <br /> 4. Steel panels and fleshings shall be 29 gauge, 80,000 PSI, painted <br /> galvanized. <br /> 5. All nails are to be threaded, hardened steel unless otherwise noted. ---Fasteners used in treated lumber shall be hot dipped galvanized stainless l. <br /> EXISTING 42'WIDE 3 <br /> k11:1 steel, or rated by the manufacturer for the application. BUILDING WITH ® ` _ S. <br /> 10'-0”EAVE HEIGHT <br /> 6. Soil shall be graded to provide drainage away from the building. Maintain AND 4112 ROOF PITCH <br /> the grade levels shown on plans around the building. <br /> 7. Fill used for concrete floor slab sub grade, if present, shall be reasonably — <br /> graded granular material. Fill used in columns holes shall be the excavated SIDE ELEVATION <br /> soil unless noted otherwise. All fill shall be free from debris, stones over <br /> CO and frozen material. <br /> 8. Heating, ventilating, air conditioning, plumbing, and electrical work is not a <-1-,b‘1 . <br /> X� <br /> part of this set of drawings and shall be instaled as per applicable codes. �`� „ •-• <br /> «. t 3f 12 <br /> BUILDING LOCATION l7U 0. a4 I �4 <br /> 3252 A RD. <br /> COTTAGE GROVE, WI 53527 I \ I \ <br /> COUNTY: DANE C)EXISTING 42'WIDE <br /> �i I BUILDING WITH I f ` <br /> 10'-4°EAVE HEIGHT I V <br /> AND 4/12 ROOF PITCH I <br /> I <br /> I <br /> Ct <br /> I , _ <br /> I 1--- O E <br /> END ELEVATION END ELEVATION W } <br /> cC <br /> (-I I w w <br /> n � CC w <br /> 0 CLEARY BUILDING CORP. TO RE-ROOF C..) _ <br /> EXISTING 42'x60' BUILDING WITH PREPAINTED <br /> ` ! ///"""48 LF. CONTINUOUS FABRAL GRAND RIB III PLUS STEEL, TRIMS, CO <br /> ' t } J PEAK VENTILATION CONTINUOUS PEAK VENTILATION AND LOW x O <br /> i j ` PROFILE EAVE VENTILATION AT BOTH SIDES Q 03 Rst <br /> r �� (CLEARY TO ALSO ADD 2x4x12' PURLINS O x <br /> BETWEEN EXISTING 24" O.C. PURLINS AT FIRST Q -c14- W J <br /> i BAY OF EXISTING BUILDING AT ATTACHMENT) <br /> 5 a - i <br /> 3 <br /> „ , <br /> ❑GARY <br /> X ,� <br /> y x / — BUILDING CORP. <br /> 1 IA i \ � I ClearyBuIIding.eom <br /> �� 0..\ i EXISTING 42'WIDE 190 PA9u STREET <br /> Iiill BUILDING WITH P.O. BOX 930220 <br /> I ANo/122 ROO HEIGHT t TABLE OF CONTENTS 80°0)a 3-5550 <br /> Elj 5 I <br /> 5 <br /> I_ 1. ELEVATIONS JOB NO. <br /> — 2. FLOOR PLAN <br /> I SIDE ELEVATION 3. DECK FRAMING PLAN 2014101352 <br /> 5 4. TYPICAL SECTION"A” <br /> 5. TYPICAL SECTION"B" <br /> 6. TYPICAL SECTION"C" SHEET <br /> 7. STAIR DETAILS <br /> y 8. TRUSS DIAGRAMS <br /> OF <br />