• <br /> Page 2_of 5 <br /> `All other services, including but not limited to the servicing of effluent filters, mechanical or pressurized components, pretreatment units, and an <br /> servicing at intervals of 512 months,shall be performed by a certified POWTS Maintainer. <br /> A service report shall be provided to the Environmental Health and Labs Division of Public Health Madison and Dane County within 30 days of • <br /> completion of any service event. <br /> START UP AND OPERATION <br /> For new construction,prior to use of the POWTS,check treatment tank(s)for the presence of painting products,solvents or other chemicals or sediment <br /> that may Impede the treatment process and/or damage the soil absorption cell(s).If high amounts of these materials are detected In the tanks,have the <br /> contents of the tank(s)removed by a septage servicing operator prior to use. <br /> System start up shall not occur when soil conditions are frozen at the Infiltrative surface. • <br /> During extended power outages pump tanks may fill above normal high•water levels.When power is restored the excess wastewater will be discharged <br /> to the dispersal cell(s)in one large dose and may overload them resulting In the backup or surface discharge or effluent.To avoid.this situation have the <br /> contests of the pump tank removed by a Septage Servicing Operator prior to restoring power to the effluent pump or contact a Plumber or POWTS <br /> Maintainer to assist in manually operating the pump controls to restore normal levers•within the pump tank. <br /> Do not drive or park vehicles over tanks and dispersal cells.Do not drive or park over,or otherwise disturb or compact,the area within 15 feet down • <br /> slope of any mound or at-grade soil absorption area. . . <br /> . <br /> Reduction or elimination of the following from the wastewater stream May Improve the performance and prolong the life of the POWTS:antlbiotics,,6aby <br /> wipes,cigarette butts, condoms,cotton swabs,degreasers,dental floss,diapers, disinfectants,fat, foundation drain (sump pump)discharge,fruit and <br /> vegetable peelings, gasoline,greases,herbicides,meat scraps;medications,oils, painting products,'pesticides,sanitary napkins, tampons,and water <br /> softener brine. <br /> ABANDONMENT <br /> When the POWTS falls and/or is permanently taken out of service the following steps shall be taken to insure that the system la properly and safely <br /> abandoned in compliance with s.fomm 83.33,Wisconsin Administrative Code: <br /> • All piping to tanks,pits and other-soil absorption systems Shall be disconnectad and the abandoned pipe openings sealed. • <br /> • The contents of all tanks and pits anal'be removed and properly disposed of by a Septage Servidng Operator(pumper). <br /> • After pumping,all tanks and pits shalt be excavated and removed or their covers removed and the void space filled with soil,gravel or another Inert <br /> solid matertal. <br /> CONTINGENCY PLAN <br /> If the POWTS falls and cannot be repaired the following measures have been,or must be taken,to provide a code compliant replacement system: <br /> to A suitable replacement area has been evaluated and may be utilized for the location of a replacement soil absorption system.The replacement <br /> area should be protected from disturbance and compaction and should not be Infringed upon by required setbacks from existing and proposed <br /> structure,lot ones and wells.Pate to protect the replacement area will result in the need.for a new soil arid site evaluation to establish a suitable <br /> replacement area.Replacement systems must comply with the rules in effect at the time of their permit Issuance. <br /> • <br /> ❑ A suitable replacement area is not available'due to setback and/or soil limitations.If the soil absorption•system cannot bq rehabilitated and barring <br /> advances in POWTS technology,a holding tank may be installed as a last resort. <br /> ❑ The site has milt been evaluated to identify:a suitable replacement area.Upon failure of the POWTS a soil and site evaluation must be performed to <br /> locate a suitable replacement area.If 04 oplacemeri afsa:Is avallal je a holding tank may be installed as a last resort toieplace the failed POWTS. <br /> ❑ Mound and at-grade 'soil absorption systema.'rtiey'be reconstructed in. place following removal of the biomat at the infiltrative surface. <br /> Reconstructions of such systems must comply with the rules In effect at that time. <br /> WARNING: TREATMENT TANKS AND HOLDING TANKS MAY CONTAIN POISONOUS GASSES AND LACK SUFFICIENT <br /> • OXYGEN TO SUPPORT LIFE. NEVER ENTER A TREATMENT TANK OR HOLDING TANK UNDER ANY <br /> CIRCUMSTANCE. DEATH MAY RESULT. ESCAPE OR RESCUE FROM THE INTERIOR OF A TANK IS VERY <br /> DIFFICULT. <br /> • <br /> ADDITIONAL INFORMATION: <br /> POWTS INSTALLER POWTS MAINTAINER <br /> Name: STEVEN CROSBY r Name: -. <br /> Phone 849-8771 Phone: SAME <br /> SEPTAGE SERVICING OPERATOR(PUMPER) LOCAL REGULATORY AUTHORITY <br /> Name: Name: MADISON-DANE COUNTY HEALTH <br /> Phone: Phone: 242-6515 <br /> This document Is intended to meet minimum requirements of Ch.Comm 83.22(2)(b)(1)(d)&(f)and 83.54(1), (2)&(3),Wisconsin Administrative Code. <br /> Use of this document does not guarantee the performance of the POP/TS. <br />