|
Help
|
About
|
Sign Out
Home
Browse
Search
DCPZP-2015-00736
DaneCounty-Planning
>
Zoning
>
1 Permits
>
2010s
>
2015
>
DCPZP-2015-00736
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/2/2015 10:30:02 AM
Creation date
9/30/2015 11:20:44 AM
Metadata
Fields
Template:
Zoning Permits
AccelaLink
DCPZP-2015-00736
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
s%� <br /> ' ' `Public Health Page_o,_ <br /> MADISON a DANE COUNTY <br /> Hea @hypeabieandilores POWTS S OWNER'S MANUAL &MANAGEMENT PLAN <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> I Ow er: I, Tank Manufacturer: NAVE ❑NA <br /> Po (, A A4 Al 4D KM C.,t La E R,T if 'Septic ❑ Dose ❑Holding Volume ( 1p 92 <br /> Permit 1 POWTS# Tank Manufacturer: 0 NA <br /> 0 Septic El Dose ❑Holding Volume G50 gal <br /> DESIGN PARAMETERS Vertical Distance Tank Bottom(s)to Service Pad: L(5 ft <br /> Number of Bedrooms: 4 NA Horizontal Distance Tank(s)to Service Pad: (4-1 0 ft <br /> Number of Public Facility Units: NA Specific servicing mechanics must be provide if vertical is>15 feet.or if <br /> Estimated(average)Flow �{ day horizontal is>150 feet.Specific instructions on plan addendum_ <br /> Design(peak)Flow=estimated x 1.5: it 0 0 ga ay' <br /> In Situ Soil Application Rate: _ gal/d ylfiZ Effluent Filter Manufacturer 017._Era L a ❑ NA <br /> Standard Domestic influent/Effluent Monthly average Effluent Filter Model: -T ff <br /> Fats,Oil&Grease(FOG) 530 mg/L Pump Manufacturer: GticA4Los ❑ NA <br /> Biochemical Oxygen Demand(BOD3) 1220 mg/L ❑NA Pump Model: 5P0 4 It A C <br /> Total Suspended Solids(TSS) x150 mg/L Pretreatment Unit <br /> High Strength Influent/Effluent Monthly average Manufacturer: <br /> Fats,Oil&Grease(FOG) >30 mg/L ❑Mechanical Aeration ❑Peat Filter . <br /> Biochemical Oxygen Demand(BOD3) >220 mg/L RNA - 0 Disinfection ❑Wetland LVNAI <br /> Total Suspended Solids(TSS) >150 mglL ❑Sand/Gravel Filter ❑Other: <br /> Pretreated Effluent Monthly average Soil Absorption System <br /> Biochemical Oxygen Demand(BOD3) 0 mg/L ❑In-Ground(gravity) ❑In-Ground(pressure) ❑ NA <br /> ITotal Suspended Solids CUSS) <_30 mg/L ['NA ❑At-Grade ❑Mound <br /> IFecal Coliform(geometric mean) SiO4 ciul100m1 ❑Drip-Line ❑Other: <br /> Maximum Effluent Particle Size: 1/8 in die. ❑ NA. • <br /> Other: RNA Other: 0 NAl44 <br /> MAINTENANCE SCHEDULE <br /> Service Event I Service Frequency <br /> Pump out contents of tank(s) I i When combined sludge and scum equals one-third(1/3)of tank volume. . <br /> I[ 'When the high water alarm is activated. <br /> inspect condition of tank(s) I At least once very 3 years. ❑ NA <br /> inspect dispersal cells(s) I At least once very 3 years_ ❑ NA <br /> Clean effluent filter eA I, ❑ NA <br /> inspect pump,pump controls&alarm lid trs.,,i, pu my F.4) l ‘2.44 .4> - ❑ NA <br /> Flush laterals and pressure test / ❑ NA <br /> Other: , ❑ NA <br /> Other: i ❑ NA <br /> MAINTENANCE INSTRUCTIONS <br /> inspections of tanks and dispersal cells shall be made by an individ r I carrying one of the following licenses or certifications:Master Plumber, Master <br /> Plumber Restricted Sewer, POWTS Inspector, POWTS Maintainer, .eptage Servicing Operator (pumper).Tank inspections must include a visual <br /> Inspection of the tank(s)to identify any missing or broken hardware,id ntify any cracks or leaks,measure the volume of combined sludge and scum and <br /> a check for any back up or ponding of effluent on the ground surface. . the volume of sludge and scum is less than one—third(113)of the liquid volume <br /> of the tank,the tank does not need to be pumped and identifying cra in floor or walls of the lank may not be possible at that fime.The dispersal cell(s) <br /> shall be visually inspected to chock the effluent levels in the obse - on pipes and to check for any ponding of effluent on the ground surface.The <br /> ponding of effluent on the ground surface may indicate a failing condition and requires the immediate notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scion in any treatmen tank equals one-third(113)or more of the tank volume,the entire contents of the <br /> tank shall be removed by a Septage Servicing Operator and drsposed .1 in accordance with chapter NR 113,Wisconsin Administrative Code. <br /> 010•P <br /> 31012 OV+rr3 MGT dor <br /> pl en. <br />
The URL can be used to link to this page
Your browser does not support the video tag.